Loading...
HomeMy WebLinkAboutC001GeneralNotes_0421202111ohohbtCCROYAL WOLF WAYROYAL WOLF WAYP R I N C E L A N E 1 F F 2 3 4 5 6 7 8 9 10 11 12 15 G G 14 13 B B C C D D E E A A PRINCE LANE### ### ### ### ### ### ### ### P R O P O S E D B U I L D I N G 3 5 , 1 0 0 S F F F E = 4 5 9 6 . 0 0 ### ### ### ### ### ###XXXXXXXXXX###GRIDLINE A-1LOCAL N:20368.73LOCAL E:29987.84GRID N:544418.58GRID E: 1562764.27GRIDLINE A-15LOCAL N:20677.50LOCAL E:30223.62GRID N:544722.33GRID E: 1563006.13GRIDLINE F-15LOCAL N:20626.65LOCAL E:30290.22GRID N:544670.16GRID E: 1563071.65GRIDLINE F-1LOCAL N:20317.88LOCAL E:30054.43GRID N:544366.42GRID E: 1562829.79GRIDLINE F-10LOCAL N:20507.81LOCAL E:30223.27GRID N:544552.77GRID E: 1563002.34LEGEND - EXISTINGWATER MAINwmASPHALTCONCRETEGRAVELSTORM DRAINstSANITARY SEWERssBURIED POWERbpBURIED TELEPHONEbtBURIED GASgasVEGETATION EXTENTSPROPERTY LINE - SUBJECTW16PROPERTY LINE - ADJACENTCONTROL POINTFOUND PROPERTY CORNER AS NOTEDFIRE HYDRANTWATER VALVEWATER WELL (ABANDONED)STORM DRAIN STRUCTURESANITARY SEWER MANHOLEUTILITY POLEPOWER VAULTPOWER METER OR POWER HANDHOLETELEPHONE/COMMUNICATIONS PEDESTALIRRIGATION CONTROL VALVEPOLE / MARKER SIGNTREECURB AND GUTTEREASEMENTOVERHEAD POWERohugLEGEND - PROPOSEDLEGEND - PROPOSEDWATER MAINWMFIRE SERVICEFFLIGHT DUTY ASPHALTLIGHT DUTY CONCRETEGRAVELDOMESTIC WATER SERVICEWSWSSTORM DRAINSTSANITARY SEWERSSBURIED POWERBPBPBURIED TELEPHONEBTBTBURIED GASGASGASXFENCE - SECURITY FENCINGBUILDINGBUILDING ROOF OVERHANGSTORM DRAIN MANHOLESTORM DRAIN INLET STRUCTURESANITARY SEWER MANHOLESANITARY SEWER CLEANOUTLIGHT POLE (ONE LIGHT AND DIRECTION)LIGHT POLE (MULTIPLE LIGHTS)TRANSFORMERPOWER METER OR POWER HANDHOLEGAS METERPOLE SIGNPIPE BOLLARDDSSTORM DRAIN ROOF DOWNSPOUTLANDSCAPE CURB/ASPHALT EDGE CURBCURB AND GUTTER - CATCHCURB AND GUTTER - SPILLHEAVY DUTY CONCRETEHEAVY DUTY ASPHALTSFSFFENCE - TEMP SILT FENCE/EROSION CONTROL BMPFLOW DIRECTIONABBREVIATIONS@ATABABANDONEDAHJAUTHORITIES HAVING JURISDICTIONAPPROXAPPROXIMATEASCEAMERICAN SOCIETY OF CIVIL ENGINEERSBC BACK OF CURBBCRBACK OF CURB RADIUSBLDGBUILDINGBMBENCHMARKBOTBOTTOMBPBURIED POWERBTBURIED TELEPHONEBWBOTTOM OF WALLC&GCURB & GUTTERCATV, TVCABLE TELEVISIONCICAST IRONCIPP CURED IN PLACE PIPE℄, CLCENTERLINECMPCORRUGATED METAL PIPECOCLEANOUTCOBCITY OF BOZEMAND, DIADIAMETERDGDECOMPOSED GRANITEDIDUCTILE IRONDIPDUCTILE IRON PIPEDOMDOMESTIC WATERDWDRIVEWAYDWGDRAWINGEGEXISTING GRADEELEC, EELECTRICEL, ELEVELEVATIONEOP, EPEDGE OF PAVEMENTEQEQUALESCPEROSION AND SEDIMENT CONTROL PLANEXEXISTINGFCFACE OF CURBFGFINISHED GRADEFH, HYDFIRE HYDRANTFLFLOW LINEFT FOOT, FEETGGASGMGAS METERGVGAS VALVEGW GUY WIREHPHIGH PRESSUREIEINVERT ELEVATIONINTINTERSECTIONIRRIRRIGATIONLLENGTHLFLINEAL FOOT, LINEAR FEETLSLANDSCAPINGLTLEFTMEGMATCH EXISTING GRADEMH MANHOLEMPWSSMONTANA PUBLIC WORKS STANDARD SPECIFICATIONS (LATEST EDITION)MTRMETERNTSNOT TO SCALEOCON CENTEROH, OHPOVERHEAD, OVERHEAD POWEROHUOVERHEAD UTILITIESPBPULL BOXPCPOINT OF CURVATUREPIPPROTECT IN PLACE⅊, PL PROPERTY LINEPPPOWER POLEPRCPOINT OF REVERSE CURVEPTPOINT OF TANGENCYPUEPUBLIC UTILITY EASEMENTPVCPOLYVINYL CHLORIDE PIPERCPREINFORCED CONCRETE PIPERIMRIM OF MANHOLE LID OR GRATEROWRIGHT OF WAYSFSQUARE FOOT, SQUARE FEETSPSPECIAL PROVISIONSSSSANITARY SEWERSSMHSANITARY SEWER MANHOLESTSTORM DRAINSTASTATIONSTCBSTORM CATCH BASINSTCISTORM CURB INLETSTDSTANDARDSTMHSTORM MANHOLESTYDSTORM YARD DRAINSWSIDEWALKSWPPPSTORMWATER POLLUTION PREVENTION PLANSYSQUARE YARDT, TELTELEPHONETATOP OF ASPHALTTBCTOP BACK OF CURBTCTOP OF CONCRETETEMPTEMPORARYTRANS TRANSITIONTWTOP OF WALLTYPTYPICALU.N.O.UNLESS NOTED OTHERWISEVCPVITRIFIED CLAY PIPEWMWATER MAINWVWATER VALVEW/WITHΔDELTAGENERAL NOTES1.ALL WORK, MATERIALS AND DETAILS PERTAINING TO CONSTRUCTION SHALL BE INCOMPLETE ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF BOZEMAN DESIGNSTANDARDS AND SPECIFICATIONS POLICY, CITY OF BOZEMAN MODIFICATIONS TO MONTANAPUBLIC WORKS STANDARD SPECIFICATIONS SIXTH EDITION, PROJECT SPECIFICATIONS, ANDALL OTHER GOVERNING AGENCIES' STANDARDS. REFER TO THE PROJECT SPECIFICATIONSFOR COMPLETE WORK COVERAGE.2.CONTRACTOR SHALL BE RESPONSIBLE FOR STORM WATER QUALITY DURINGCONSTRUCTION. CONTRACTOR SHALL OBTAIN AND COMPLY WITH ALL CURRENTREQUIREMENTS OF THE NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES),AND LOCAL MS4 REQUIREMENTS WHERE APPLICABLE. THE CONTRACTOR IS RESPONSIBLEFOR THE PREPARATION AND MAINTENANCE OF A STORMWATER POLLUTION PREVENTIONPLAN (SWPPP) THROUGHOUT THE DURATION OF THE PROJECT.3.THE CONTRACTOR SHALL PROTECT ADJACENT PROPERTIES, PUBLIC AND PRIVATE, AT ALLTIMES DURING CONSTRUCTION.4.THE CONTRACTOR SHALL CONTROL DUST IN ACCORDANCE WITH REGULATIONS OF LOCALAIR POLLUTION CONTROL AUTHORITY.5.CONTRACTOR TO PROTECT ALL EXISTING UTILITIES, SIGNS AND EXISTING STRUCTURES.THE CONTRACTOR IS RESPONSIBLE TO REPAIR BACK TO ORIGINAL OR BETTER CONDITION IFDAMAGE HAS OCCURRED DURING CONSTRUCTION.6.CONTRACTOR SHALL REVIEW EXISTING CONDITIONS AND COORDINATE WITH UPS PROJECTENGINEER, CITY OF BOZEMAN AND ENGINEER / ARCHITECT PRIOR TO DEMOLITIONACTIVITIES.7.TRAFFIC, BOTH VEHICULAR AND PEDESTRIAN SHALL BE PROTECTED BY EFFECTIVEBARRICADES AND SIGNS IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFICCONTROL DEVICES (MUTCD) GUIDANCE AND AS REQUIRED BY THE AUTHORITY HAVINGJURISDICTION. EFFECTIVE LIGHTING OF OBSTRUCTIONS SHALL BE PROVIDED AT NIGHT.8.CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH PERMITREQUIREMENTS.9.UNLESS OTHERWISE INDICATED, ALL CONSTRUCTION STAKING SHALL BE PERFORMEDUNDER THE RESPONSIBLE CHARGE OF A MONTANA LICENSED LAND SURVEYOR, AT THECONTRACTORS EXPENSE.10.THE CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF APPROVED DRAWINGS ON THECONSTRUCTION SITE AT ALL TIMES. ANY APPROVED DEVIATIONS IN CONSTRUCTION FROMTHE APPROVED DRAWINGS SHALL BE NOTED ON THIS SET. THE LOCATION AND DEPTH OFALL UTILITIES ENCOUNTERED SHALL BE RECORDED AND KEPT UP TO DATE AT ALL TIMESAND AVAILABLE FOR INSPECTION BY THE OWNER'S REPRESENTATIVE UPON REQUEST.FAILURE TO COMPLY MAY RESULT IN DELAY IN PAYMENT AND/OR FINAL ACCEPTANCE OFTHE PROJECT.11.UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A CLEAN SET OFFIELD DRAWINGS CONTAINING ALL AS-BUILT INFORMATION TO THE UPS PROJECT ENGINEER.12.IF WITHIN ONE YEAR OF THE FINAL ACCEPTANCE BY THE UPS PROJECT ENGINEER, ANYWORK IS FOUND TO BE DEFECTIVE OR NOT IN ACCORDANCE WITH THE CONTRACTDOCUMENTS AND/OR DRAWINGS, AND UPON WRITTEN NOTICE FROM THE UPS PROJECTENGINEER, THE CONTRACTOR SHALL CORRECT ANY WORK BEGINNING WITHIN SEVEN (7)CALENDAR DAYS OF RECEIPT OF NOTICE. SHOULD THE CONTRACTOR FAIL TO RESPOND TOTHE WRITTEN NOTICE, THE OWNER MAY CORRECT THE WORK AT THE CONTRACTOR'SEXPENSE.13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR IMPORTING AND/OR EXPORTING ALLMATERIAL AS REQUIRED TO PROPERLY GRADE THIS SITE TO THE FINISHED ELEVATIONSSHOWN HEREON AS WELL AS THE LEGAL DISPOSAL OF WASTE IN ACCORDANCE WITH THEAPPROVED PLANS AND SPECIFICATIONS.14.CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL SITE WORK WITH ALL OTHER TRADES.15.SAFETY - NEITHER THE OWNER NOR THE ENGINEER WILL BE RESPONSIBLE FORCOMPLIANCE WITH SAFETY MEASURES OR REGULATIONS. THE CONTRACTOR SHALLDESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES, AND SHALL BE SOLELYRESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTHSTANDARDS, LAWS, AND REGULATIONS.16.NO BURNING ON SITE IS ALLOWED.17.THE CONTRACTOR IS RESPONSIBLE TO CALL 1-800-424-5555 (OR 811) AT LEAST 2 WORKINGDAYS PRIOR TO ANY EARTH DISTURBING ACTIVITIES OR UTILITY EXCAVATIONS.ACCESS NOTES1.CONTRACTOR SHALL COORDINATE ACCESS, STAGING AND STOCKPILE LOCATIONS WITH THEUPS PROJECT ENGINEER.2.CONTRACTOR SHALL RESTORE DISTURBED AREAS TO PRE-CONSTRUCTION OR BETTERCONDITIONS.EXISTING UTILITY NOTES1.EXISTING UNDERGROUND INSTALLATIONS AND PUBLIC UTILITIES SHOWN ARE INDICATEDACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER AND DEPICTED ONTHESE PLANS TO A LEVEL OF QUALITY IN ACCORDANCE WITH ASCE 38-02.2.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR LOCATING AND VERIFYINGMATERIAL TYPES OF ALL EXISTING UTILITY INSTALLATIONS ABOVE AND BELOW GROUND INADVANCE OF THE PROJECT BY CONTACTING THEIR RESPECTIVE OWNERS. ALL COSTSRELATED TO LOCATING EXISTING UTILITIES ARE INCIDENTAL AND SHALL NOT BE PAIDSEPARATELY. NOT ALL UTILITIES ARE IDENTIFIED ON THE PLANS. NOTIFY ENGINEER OFPOTENTIAL CONFLICTS.3.THE CONTRACTOR SHALL NOTIFY THE UPS PROJECT ENGINEER AND THE CITY OF BOZEMANA MINIMUM OF 5 BUSINESS DAYS PRIOR TO THE START OF CONSTRUCTION.DRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®PARCEL DISTRIBUTION FACILITY UPS BOZEMAN, MONTANASITE PLAN SUBMITTAL04.21.20212021Know what'sbelow.Callbefore you dig.6/9/2021 11:05 AM | L:\UPS_BOZEMAN\BIMCAD\Civil\UPS_BZMN_C001.dwgC001GENERAL NOTES& LEGENDSCHLEGEL-WHITE1C001KEYMAP AND HORIZONTAL CONTROLNORTH050100200SCALE: 1" = 100'1C1011C2011C1031C2031C1021C2022C1032C203POWER AND GAS SERVICENORTHWESTERN ENERGY121 E. Griffin DrBozeman, MT 59715Engineer Contact: Matt Tilstra406.223.9730UTILITY CONTACTSTELEPHONECENTURYLINK502 S 19th AveBozeman, MT 59715Contact: Elaine Castillo406.500.3030elain.castillo@centurylink.comFIBER OPTICCHARTER1500 N 19th AveBozeman, MT 59715Contact: Jared Phillips, Rob Leiva866.874.2389PUBLIC WATER SUPPLYCITY OF BOZEMAN814 N. Bozeman StreetBozeman, MT 59715Contact: Nick Pericich or John Alston406.582.3200GAS PIPELINEPHILLIPS 66318 W. Griffin DrBozeman, MT 59715Engineer Contact: Chase Keith406.587.6060