Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A101FloorPlans04212021
FFFFFFFFFFFFAAPASSEMBLY TYPE (SEE ASSEMBLIES SHEET)ASSEMBLY MODIFIER, PER TYPEROOM NAME AND NUMBERKEYNOTEDRAWING NUMBERSHEET WHERE DRAWNDOOR NUMBER (SEE SHEET A601)DIMENSION TO FACE OF FRAMINGDIMENSION TO GRID LINE101-11A101SIM______________WXXXNAME101#PLAN LEGENDDIRECTION OF VIEW, IF APPLICABLEDIMENSION TO CENTER LINECLSURFACE MOUNTED FIRE EXTINGUISHER SEE SPECIFICATIONS TYPES ARE DESIGNATED AS "X"FE-X?WINDOW TAG, SEE A602 WINDOW SCHEDULEAA2013A201A201141FF167 SFCONFERENCE106CLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCL1'-2"14'-3"28'-0"28'-0"28'-0"16'-10"14'-2"25'-0"28'-0"28'-0"28'-0"15'-2"5'-4"63'-6"12'-0"12'-0"12'-0"12'-0"18'-3"1A301______________3A301______________1A302______________4A310______________253'-5"55'-4"79'-9"83'-9 1/2"18'-11"294 SFGSS OFFICE1052345678910111216GG257 SFCUSTOMERCENTER1012272 SFAUTO SHOP1108212 SFUNLOADBAYS10221393 SFLOADINGBAYS1111514103 SFMANAGEROFFICE107BBCCDDEECLCLCL1'-1"3'-5"38'-6"38'-6"3'-4 1/2"1'-1"CL5'-0"402 SFFIRE RISER109CLCLCLCLCLCLCLCLCLCLCLCLCLCL1'-2"14'-3"28'-0"28'-0"28'-0"16'-9 1/2"14'-2 1/2"25'-0"28'-0"28'-0"25'-0"14'-4"3'-10"2'-4"15'-5"25'-2"12'-5"69'-9"10'-0"1'-2"388'-6"102-3102-2102-1111-1111-2111-3111-4111-5111-7111-8111-9111-10111-11111-12111-13111-14 111-15 111-16 111-17111-18111-19 111-20 111-21 111-22 111-23111-24102-8102-9102-72A301______________W1W1W1W2______________A7021______________A701121'-1"14'-4"13'-0"14'-4"28'-3"28'-0"28'-0"28'-0"28'-0"28'-0"28'-0"28'-0"29'-2"30'-10"24'-6"13'-6"18'-0"24'-0"24'-3"111-6203 SFWOMEN'SRESTROOM104189 SFMEN'SRESTROOM103161 SFMEN'SLOCKER103.12A302______________1'-1 3/4"12'-4 1/4"1'-0"______________A3111AAFE-AFE-AFE-BFE-AFE-A101'-11"100'-0"100'-0"100'-0"100'-0"FE-AFE-AFE-AFE-AFE-AFE-AFE-BFE-AFE-ACL23A304______________A2021A2022A2023A2024F1F111'-11 5/8"3'-6"14'-4"SLOPE 1%SLOPE 1%SLOPE 1%SLOPE 1%100'-0"100'-0"100'-0"13'-2 1/2"12'-4"15'-8"CLCL13'-7"2'-6"25'-6"CL133333445F336 SFSERVERROOM202______________A7012117 SFMANAGEROFFICE201606 SFMECH205133 SFSTORAGE20312161514E241 SFCONFERENCE2042A301______________110'-0"FE-AFE-CF213#KEYNOTESGENERAL NOTESA. SEE SHEET G102 REGARDING BUILDING CODE REQUIREMENTS.B. SEE SHEETS A901 AND A902 FOR REFLECTED CEILING PLANS AND DETAILS. C. FOR SIZE AND CONNECTION DETAILS OF STEEL FRAMING COMPONENTS, STEEL BEAMS, STEEL DECKING AND OTHER STEEL SECTIONS – SEE STRUCTURAL FOR COORDINATION AND REQUIREMENTS.D. COORDINATE ALL PLUMBING FIXTURES LOCATIONS WITH PLUMBING DRAWINGS AND INSTALLED CONDITIONS IN THE FIELD.NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS6/9/2021 12:03:43 PMFLOOR PLANSA10105-14-2021© 2020 | ALL RIGHTS RESERVED100% CONSTRUCTIONDOCUMENTSDESIGNED BY | KRAHNDRAWN BY | SMITHPARCEL DISTRIBUTION FACILITYUPS BOZEMAN, MONTANA | Project# UPS_BOZEMAN | L:\UPS_BOZEMAN\BIMCAD\Revit1/16" = 1'-0"A1011FIRST FLOOR PLANNORTH REF1/16" = 1'-0"A1012SECOND FLOOR PLANNORTH REF1 NOT USED2 EXPANSION WALL FOR FUTURE GROWTH3 CONCRETE APRON, SEE CIVIL, TYP4 TRENCH DRAINS, SEE PLUMBING5 ENCLOSURE FOR MECHANICAL, SEE PLAN AND SECTION DETAILS ON SHEET A315SITE PLAN SUBMITTAL04.21.2021