Loading...
HomeMy WebLinkAbout4192025 C504 Fire Submittal 2021-05-248''SS8''W8''W8''W8''SS8''SS8''SS8''SS8''SS8''SSSTORMSTORM 8''W8''W8''W8''W8''W8''WFIRE FIRE WS WS WS STORMSTORM8''SS8''W8''W8''W8''SS8''SS8''SS8''SS8''SS8''SSSTORMSTORM 8''W8''W8''W8''W8''W8''W-0+450+000+33WS WS WS WS WS WS WS WWWSSSSWWSS SS WS FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE DYH-0+050+000+808''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''W8''W8''W8''W8''W8''W8''W8''WWSWSWSWSWSFIREFIREFIREFIREFIRE8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''W8''W8''W8''W8''W8''W8''W8''W-0+050+000+454730 4740 4750 4730 4740 4750 FG-EG--0+45 FG-4744.51EG-4744.510+00 FG-4744.16EG-4744.160+33 2.0'TS6.5 MIN BURY DEPTH NO JOINTS ALLOWED BTWN 90° VERTICAL BEND & OS&Y VALVE OS&Y VALVE BLDG FINISHED FLOOR EL. 4748.15 BLDG INSTALL WATER TIGHT SLEEVE PER NFPA CODE. 2" CLEARANCE BETWEEN CONCRETE & PIPE MAINTAIN 2' CLEARANCE BETWEEN PIPE FACE AND INSDE EDGE OF EXTERIOR WALL & 1' CLEARANCE BETWEEN PIPE FACE & INTERIOR WALLS. EX 8" DI WATER MAIN VERIFY ELEVATION EX 4" DI FIRE SERVICE STUB VERIFY ELEVATION FINISHED GRADE EXISTING GRADE 27 LF CL 51 4" FIRE SERVICE STA 0+00.00 22.5° BEND VERIFY INVERT ELEVATION INV. ±4737.78 STA -0+01.00 4" GATE VALVE VERIFY INV ELEV INV. ±4737.78 4740 4750 4760 4740 4750 4760 FG-4747.74EG-4747.74-0+05 FG-4747.59EG-4747.590+00 FG-4746.83EG-4746.830+45 FINISHED GRADE EXISTING GRADE STA 0+00 HOT TAP EX 8" DI WATER MAIN INV. ±4741.00 CONTRACTOR TO VERIFY ELEVATION STA 0+01.78 4" GATE VALVE INV. ±4740.83 6.5 MIN BURY DEPTH TSINSTALL WATER TIGHT SLEEVE PER NFPA CODE. 2" CLEARANCE BETWEEN CONCRETE & PIPE MAINTAIN 2' CLEARANCE BETWEEN PIPE FACE AND INSDE EDGE OF EXTERIOR WALL & 1' CLEARANCE BETWEEN PIPE FACE & INTERIOR WALLS. ±42 LF CL 51 4" FIRE SERVICE CLASS 1 SYSTEM BLDG FINISHED FLOOR EL. 4750.00 4730 4740 4750 4730 4740 4750 FG-4743.79EG-4743.79-0+05 FG-4743.78EG-4743.780+00 FG-4743.87EG-4743.87FG-EG-0+80 FINISHED GRADE EXISTING GRADE 6.5 MIN BURY DEPTH STA 0+00.00 8"X 4" TEE INV. 4736.50' STA 0+1.12 4" GATE VALVE INV. 4736.67' STA 0+13.89 4" 11.25° BEND INV. 4736.50'TSINSTALL WATER TIGHT SLEEVE PER NFPA CODE. 2" CLEARANCE BETWEEN CONCRETE & PIPE MAINTAIN 2' CLEARANCE BETWEEN PIPE FACE AND INSDE EDGE OF EXTERIOR WALL & 1' CLEARANCE BETWEEN PIPE FACE & INTERIOR WALLS. BLDG FINISHED FLOOR EL. 4746.75 STA 0+73.96 4" 90° VERTICAL BEND AND THRUST BLOCK INV. 4739.89 ±74 LF CL 51 4" FIRE SERVICE CLASS 1 SYSTEM STA 0+73.96 INSTALL 4" DI FIRE SERVICE RISER THRUST BLOCK & FLANGED OS&Y VALVE. SEE SPRINKLER DESIGN PLANS FOR INFO BEYOND OS&Y VALVE, CONTRACTOR TO CONFIRM SIZE AND LOCATION INSIDE BUILDING PRIOR TO PLACEMENT OF SERVICE. VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2021COPYRIGHT © MORRISON-MAIERLE, INC., SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\4192\025 - THE BOULDERS SITE DEVELOPMENT\ACAD\SHEETS\4192025 C503 FIRE SUBMITTAL.DWG PLOTTED BY:CELINE SAUCIER ON Jun/04/2021 REVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle BOULDER CREEK APARTMENTS 4192.025 MONTANA FIRE SERVICE SUBMITTAL C504 CMS CMS MEE 8/2020 1 REVISION 1 - C.O.B. DRC REVIEW 8/10/2020CMS 3 REVISION 3 - DRC COMMENTS 5/24/2021CMS 2 REVISION 2 - DRC COMMENTS 2/12/2021CMS BOZEMAN SCALE: 1" = 10' FIRE SERVICE 1 PLAN SCALE: 1" = 10' FIRE SERVICE 2 PLAN GRAPHIC SCALE 0 (IN FEET) 5 10510 1 INCH = 10 FT GRAPHIC SCALE 0 (IN FEET) 5 10510 1 INCH = 10 FT GRAPHIC SCALE 0 (IN FEET) 5 10510 1 INCH = 10 FT PHASE II - 18 PLEX FFE = 4750 PHASE I - 12 PLEX FFE = 4748.15 PHASE III- 12 PLEX FFE = 4746.75 8" DI WATER MAIN STA 0+13.89 4" 11.25° BEND STA 0+00 8"X4" TEE 1-1/2" TYPE K COPPER WATER SERVICE EX 8" DI WATER MAIN STA 0+00.00 REMOVE EX 4" CAP AND BLOW-OFF ASSEMBLY. CONNECT NEW 4" 11.25° BEND, 4" GATE VALVE AND 4" DI PIPE. VERIFY INVERT ELEV. PRIOR TO CONNECTION EX 1.5" WATER SERVICE STUB STA 0+25.94 INSTALL 4" DI FIRE SERVICE RISER THRUST BLOCK & FLANGED OS&Y VALVE. SEE SPRINKLER DESIGN PLANS FOR INFO BEYOND OS&Y VALVE, CONTRACTOR TO CONFIRM SIZE AND LOCATION INSIDE BUILDING PRIOR TO PLACEMENT OF SERVICE. STA 0+41.96 INSTALL 4" DI FIRE SERVICE RISER THRUST BLOCK & FLANGED OS&Y VALVE. SEE SPRINKLER DESIGN PLANS FOR INFO BEYOND OS&Y VALVE, CONTRACTOR TO CONFIRM SIZE AND LOCATION INSIDE BUILDING PRIOR TO PLACEMENT OF SERVICE. EX 8" DI WATER MAIN STA 0+00 CONNECT TO EX 8" MAIN HOT TAP EX 8" MAIN WITH 8" X4" TAPPING TEE AND THRUST BLOCK 1-1/2" TYPE K COPPER WATER SERIVCE SAWCUT AND REMOVE EX ASPHALT AND CURB AND GUTTER. BACKFILL TRENCH WITH FLOWABLE FILL TACK COAT AND SEAL ALL JOINTS. REPLACE ASPHALT TO MATCH EX THICKNESS. REPLACE CURB AND GUTTER PER C.O.B. STANDARDS. SCALE: 1" = 10' FIRE SERVICE 2 PLAN 8/10/20