Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4192025 C040 Water Details 2021-05-24
CORPORATIONSTOPTRENCHBOTTOMWATER SERVICEPIPE (3/4" Ø MIN.)12346" (MIN)GENERAL NOTES:1.WATER SERVICE LINES SHALL HAVE A MINIMUM COVER OF 6.5' (78") AS MEASURED FROM THEEXISTING GROUND SURFACE, EXCEPT THAT COVER SHALL BE MEASURED FROM THE CENTERLINESTREET GRADE WHEN SERVICE LINES ARE LAID TO A STREET SIDE THAT HAS AN UPHILL SLOPE.WATER SERVICE LINES SHALL HAVE A MAXIMUM COVER OF 7.5' (90") AT THE CURB STOP.2.WATER SERVICE LINES SHALL BE INSTALLED WHERE SHOWN ON THE DRAWINGS OR AS SPECIFIED.3.BEDDING SHALL BE ONE INCH (1") DIAMETER MAXIMUM WITHIN SIX INCHES (6") OF SERVICE PIPE.4.INSTALL CURB STOP SO THAT OPERATING KEY IS PARALLEL TO STREET IN OFF-POSITION.DETAIL OF APROPERLY INSTALLEDCORPORATION STOP.TAP MAIN AT SPRINGLINE.SELECT MATERIAL BACKFILL AREA(SEE SPECIFICATIONS)8'-0"11'-6"(TYP)(TYPICAL TYPICAL EXCEPT INSPECIAL CIRCUMSTANCESWHERE CITY HAS APPROVEDALTERNATE LOCATION)CURB STOPBASEMATERIALPROVIDE 5'STATIONARYROD IN ALLCURB BOXESCURB BOX2'-6"1'-0"4'-0"STEEL POSTMARKERPAINTED BLUEGROUNDSURFACEPROPERTY LINEOR EASEMENT1'-0"5' SIDEWALK(TYP)5'-6" BOULEVARD(TYP)STREETSURFACE6'-6"COVER(MIN)TAP BYCONTRACTORWATER MAINSEE DETAILBELOWNO COUPLINGS OR OTHER JOINTS ARE ALLOWED ON SERVICE PIPE FROMCORPORATION STOP TO CURB STOP FOR 3/4" AND 1" SERVICES.STRAIGHT COPPER PIPE SHALL BE USED FOR 1-1/2" AND 2" SERVICES.1'-0" (MIN) &2'-0" (MAX)WATER SERVICE LINE STUB(SEE C.O.B. STANDARD DRAWING NO. 02660-6)PROPERTY LINEOR EASEMENTSERVICE LINE1'-0" (MIN) &2'-0" (MAX)1'-0" (MIN) &2'-0" (MAX)FOUNDATIONWALLBACKFLOW PREVENTIONASSEMBLY (AS REQUIRED)TO DOMESTICFIXTURESDOWNSTREAMSHUT-OFF**FLOORMETER*ANGLE STOP ORSTRAIGHT STOP*METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECT DIRECTLYTO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE**DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICEDETAIL ATYPICAL WALL PENETRATION(NOT TO SCALE)1'-0" (MIN)TO DOMESTICFIXTURESDOWNSTREAMSHUT-OFF**FOUNDATIONWALLMETER*ANGLE STOPBACKFLOW PREVENTIONASSEMBLY (AS REQUIRED)QUARTER-BEND COUPLING(1-1/2" & 2" SERVICES ONLY)*METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECTDIRECTLY TO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE**DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICEDETAIL BTYPICAL FLOOR PENETRATION (CRAWL SPACE)(NOT TO SCALE)WATER MAINCURB STOPAND BOXNEAREST FOUNDATIONWALL TO CURB STOPSEE DETAILSA & B BELOW6'-6" (78")(MIN)COVERWATER SERVICE LINEINSTALLED BY CUSTOMER(SERVICE APPLICATION & PLUMBING PERMIT REQUIRED)INSTALLATION REQUIREMENTS:1.WATER SERVICE LINE INSTALLATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF BOZEMAN WATER SUPERINTENDANT.2.SERVICE LINES SHALL BE TYPE K COPPER FOR 3/4", 1", 1-1/2", AND 2" SERVICES. REFER TO C.O.B. STANDARD DRAWING NO. 02660-12 FOR 4" AND LARGER DOMESTIC SERVICE LINES. SERVICE LINES BETWEEN 2" AND 4" ARE NOT ALLOWED.3.STRAIGHT COPPER TUBING SHALL BE USED FOR 1-1/2" AND 2" SERVICES.4.SERVICE LINES SHALL BE BEDDED 3" UNDER AND OVER THE PIPE WITH SAND. NATIVE MATERIAL MAY BE USED AS BEDDING IF IT CONFORMS TO THE REQUIREMENTS OF MONTANA PUBLICWORKS STANDARD DRAWING 02221-2 AND DOES NOT CONTAIN ANY MATERIAL LARGER THAN 3/4".5.PROVIDE FLEXIBLE, WATER TIGHT CONNECTION FOR ALL WALL OR FLOOR PIPE PENETRATIONS.6.METERS SHALL BE INSTALLED BY THE CITY WATER DEPARTMENT AT CUSTOMERS' EXPENSE.7.NO SERVICE LINE SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE WATER DEPARTMENT.8.CONTACT CITY OF BOZEMAN WATER DEPARTMENT FOR APPROVED LIST OF COPPER CONNECTIONS.9.WATER SERVICE LINE MAY BE REDUCED TO A SMALLER SIZE THAN THE WATER SERVICE STUB. REDUCTION MUST BE MADE WITHIN 18" OF CURB STOP.10.METER, BACKFLOW PROTECTION, AND INCOMING SERVICE LINE MUST ALL BE THE SAME SIZE.VERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2021COPYRIGHT © MORRISON-MAIERLE, INC.,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYN:\4192\025 - THE BOULDERS SITE DEVELOPMENT\ACAD\SHEETS\4192025 C040 WATER DETAILS.DWG PLOTTED BY:CELINE SAUCIER ON Jun/03/2021REVISIONSDRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierleBOULDER CREEK APARTMENTS4192.025MONTANAWATER DETAILSC040 CMS CMSMEE8/10/2020 1REVISION 1 - C.O.B. DRC REVIEW8/10/2020CMS 3REVISION 3 - DRC COMMENT5/24/2021CMS2REVISION 2 - DRC COMMENT2/21/2021CMSBOZEMAN Know what'sbelow.before you dig.CallRKnow what'sbelow.before you dig.CallRNOT TO SCALEWATER SERVICE LINE DETAIL02660-6NOT TO SCALEWATER SERVICE LINE DETAIL FROM CURB STOP TO BUILDING - LINES 2" & SMALLER02660-158/10/2020