Loading...
HomeMy WebLinkAbout19 - Design Report - Cannery District Ph 3 - Sewer Sewer Engineer’s Report Cannery District PUD Phase 3 Update April 4, 2019 For Submittal to: City of Bozeman Engineering Department 20 East Olive Bozeman, MT 59715 Montana Department of Environmental Quality Permitting and Compliance Division Public Water and Subdivisions Bureau PO Box 200901 Helena, MT 59620-0901 Prepared by: Stahly Engineering and Associates 851 Bridger Drive, Suite 1 Bozeman, MT 59715 (406) 522-9526 Sewer Engineer’s Report 1 4/8/2019 Engineer’s Sewer Report Contents Note: The Engineer’s Report format for the Cannery District Phase 3 Sewer report follows DEQ-2 organization. Additional information required by the City of Bozeman Design Standards is added where required. Report Narrative Chapter 10 – Engineering Reports & Facility Plans 11.1 Engineering Report 11.11 Problem Defined 11.12 Design Conditions 11.13 Impact on Existing Wastewater Facilities 11.14 Project Description 11.15 Design Criteria 11.16 Site Information 11.17 Environmental Impacts Figures and Tables Figure 1. Vicinity Map Figure 2. Sewer Site Plan (included separately) Table 1. Cannery District Sewer Flow Estimates Table 2. Capacity of 8” and 10” SDR 35 PVC Sewer Main Appendices A Table 1. Detailed Cannery District Water Usage Sewer Engineer’s Report 2 4/8/2019 11.1 Engineering Report The Cannery District is a multi-phase development located on the north side of East Oak Street and Rouse Avenue, north of the Gallatin County Fairgrounds. The existing property consists of several parcels of land within the City and County, with 5.24 acres within the City and 6.98 acres within the county. The development consists of four phases. The first phase, which was completed in 2016, consisted of remodeling four existing buildings originally constructed as part of the original pea canning operation in 1917. During this phase, the original water and sewer infrastructure was replaced and upgraded to current City standards. Phases 2, 3 and 4 include the construction of six new buildings on the Cannery District property. Phases 2 and 4 improvements were completed in 2018, leaving only the proposed Phase 3 improvements unconstructed. This report is addresses the improvements of the final phase of the Cannery District PUD (Phase 3), and compares the originally-estimated sewer demands with demands based on actual uses of the built-out development. The wastewater flows from these future phases were accounted for in the design of the previously constructed Phases 1, 2 and 4 system. All county lands will be annexed prior to development in order to receive municipal services for the new buildings. The developer’s contact information is: Cannery District Partners, LLC 113 East Oak Street, Ste 4A Bozeman, MT 59715 Water supply and wastewater treatment will continue to be provided by the City of Bozeman’s municipal systems. The system owner’s contact information is: City of Bozeman Public Service Department PO Box 1230 Bozeman, MT 59771-1230 The location of the Cannery District is shown on the Vicinity Map in Figure 1. See Figure 2 for the overall sewer system plan. Sewer Engineer’s Report 3 4/8/2019 Figure 1. Vicinity Map, Bozeman, Montana 11.11 Problem Defined City of Bozeman sewer mains were constructed in 1917 to serve the original buildings. The previously constructed Phase 1 and 2 sewer upgrades replaced these original sewer mains and provide the backbone of the infrastructure needed to serve the remaining Cannery District phases. The remaining phase requires only additional sewer services. The location of the previously constructed sewer mains, and proposed sewer services are shown in Figure 2, which is included separately. 11.12 Design Conditions The initial sewer flow estimated contributed by the Cannery District was determined using wastewater flow rates for zoned undeveloped areas from the City of Bozeman Design Standards and Specifications Policy, Table V-1. Table V-1 shows a flow rate of 2,000 Gal./Acre/Day for zoning designation B- 2. This water use estimate using this flow rate resulted in a design peak hour flow of 212 gpm. Since the Cannery District is largely built out, and the specific uses of the proposed Phase 3 buildings are known, water usage for this phase and the entire development was determined using the following values for average water use rates: Office/Retail 10,000 gal/yr/1,000 sf Restaurant 165,000 gal/yr/1,000 sf Residential 89 gal/day/person Sewer Engineer’s Report 4 4/8/2019 The wastewater flow estimates are shown in Table 1. The revised estimated sewer flows, based on actual developed uses, is reduced to 191 gpm, versus the originally-estimated 212 gpm. Table 1: Cannery District Sewer Flow Estimates Cannery District Water Use  Cannery District  Northside  PUD  Total w/  Northside  Phase  1  Phase  2  Phase  3  Phase  4  All  Phases  Acreage (acres) 3.761 3.29 3.237 1.946 12.234 3.024 15.254  Design Water Use Rate (gpd/acre)* n/a n/a n/a n/a n/a 2,000 n/a  Design Daily Water Use (gpd)* 9,710 1,895 8,248 1,636 21,489 6,048 27,537  Design Peaking Factor (Ave Day to Peak Hour) 10 10 10 10 10 10 10  Design Peak Hour Flow (gpm) 67 13 57 11 149 42 191  * See detailed water use estimates organized by phase and buildings based on actual use areas in Appendix. The previously constructed Phase 1 sewer network consists of both 8” and 10” SDR 35 PVC sewer mains. 8” SDR 35 PVC sewer mains installed at the minimum slope of 0.4% have a flow capacity of 312.8 gpm using 75% of the flow depth of the pipe as required by the City of Bozeman Design Standards and Specifications Policy. 10” SDR 35 PVC sewer mains installed at the slope of 0.3% have a flow capacity of 491.2 gpm using 75% of the flow depth of the pipe. See Table 2 below for the parameters used in the flow calculation. Table 2: Capacity of 8” and 10” SDR 35 PVC Sewer Main Capacity of 8" and 10" SDR 35 PVC Sewer Pipe  Status Existing &Proposed Proposed  Location Cannery District Cannery District  Pipe Material 8" SDR 35 PVC 10" SDR 35 PVC  Pipe Diameter (in) 8 10  Minimum Pipe Slope (ft/ft) 0.004 0.003  Coefficient of Roughness (n) 0.013 0.013  Depth in Pipe at 75% Full (in) 6 7.5  Depth of Flow (ft) 0.5 0.625  Pipe Radius (in) 4 5  Pipe Radius (ft) 0.33 0.42  Wetted Perimeter 1.40 1.75 Area of Flow (ft2) 0.28 0.44 Hydraulic Radius 0.20 0.25 Velocity (ft/sec) 2.48 2.49 Maximum Pipe Flowrate (gpm) 312.8 491.2  Peak Hour Flow (gpm) 191 191  Peak Flow % of Max Capacity 61.13% 38.93%  Sewer Engineer’s Report 5 4/8/2019 The existing 8” and 10” sewer mains constructed in previous phases has enough capacity to convey the peak flows from all four phases of the Cannery District, as well as flows from the existing Northside PUD. 11.13 Impact on Existing Wastewater Facilities The majority of the sewer network for the Cannery District was completed during previous phases. The proposed Phase 3 does not include any main extensions, but requires new and relocated sewer services. During construction of Phase 3, existing sewer services within the Cannery District and Northside PUD will remain in service. 11.14 Project Description Cannery District Phase 3 is the fourth of four phases within the development. It consists of the construction of two new buildings (Buildings ‘L’ and ‘M’ as shown in Figure 2). The construction of Phases 1 and 2 has provided the majority of the infrastructure needed to serve the remaining phases. Sewer services will be connected to the previously-installed 10” main that flows from west to east along the north side of the proposed buildings. Building ‘L’ will be a mixed-use building containing office and residential units; it will have an 8” sewer service line and connect to the adjacent 10” main. Building ‘M’ will be an office building and connect to the existing 4” sewer service line currently being utilized by Building ‘D’ (within the Northside PUD). Building ‘D’ will get a new, re-routed 4” sanitary service connecting into the same 10” sewer main, approximately 70 feet east of its current connection point (see Figure 2). 11.15 Design Criteria The Cannery District sewer main extensions were designed in accordance with Montana Department of Environmental Quality Circular 2, Montana Public Works Standards and Specifications, City of Bozeman Modifications to Montana Public Works Standards and Specifications, the Uniform Plumbing Code, and the City of Bozeman Wastewater Facility Plan. 11.16 Site Information A Geotechnical Report was prepared by Allied Engineering Services, Inc. for the Cannery District site. The report identified the site to contain fine grained soils overlying gravel deposits. Geotechnical borings have determined the general soil profile consists of 1.5 to 7.0 feet of fine grain silt and clay overlying alluvial gravel. Estimated depth to groundwater obtained from the Sewer Engineer’s Report 6 4/8/2019 geotechnical borings is 6.5 -11 feet. If mains are installed during high groundwater times dewatering may be required. 11.17 Environmental Impacts Continued use and new extensions of City of Bozeman municipal sewer mains has the least environmental impact. No new environmental impacts will be caused by these sewer main extensions. Figure 2 Sewer Site Plan OAK STREETSTORMWATERRETENTION BASIN/SNOW STORAGESDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS30 SPACES40 SPACES15 SPACES22 SPACES22 SPACES20 SPACES9 SPACES6 SPACES8 SPACES23 SPACES13 SPACES 11 SPACESSDSDSD SDSDSDWATERTOWERBLDG OBLDG HBLDG NBLDG GBLDG FBLDG KBLDG JBLDG CBLDG DBLDG BBLDG A32 SPACES29 SPACESPARKING PLAZA14 SPACESEXISTINGFAIRGROUNDSACCESS ROUSE AVE RAIL TRAILTRASHTRASHTRASH20' ROW FOR OAKSS SS SS SS SS SS SS SS SS SD SD SD SD SD SD SD SD SD 8''W8''W8''W8''W8''W8''W8''W8''WSDSDSTORIESSS SS SSUSE DESIGNATIONGROSSAREA(SF)PHASE 4BLDG N5,412210,296OFFICESSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSBLDG ESD SD SD SD SD SD SD SD SD SD SD SD SDSDSDSDSDSDSDSD SD SD SD SD SDSDSDSD 10 SPACESSS SS SS SS SSSS5 SPACES 25 SPACESTOWER TRAIL TRASHSD8 SPACES17 SPACESSS SS STORMWATER BIOSWALE/SNOW STORAGEPHASE/BUILDINGPHASE 1BLDG E9,231428,333RETAIL, RESTAURANT, OFFICEBLDG F12,0201&215,751RETAIL, BREWERY, OFFICEBLDG G13,7601&219,324OFFICEBLDG H1,6001&22,100OFFICEFOOT-PRINT(SF)PHASE 2BLDG K8,9621+MEZZ11,838MEDICAL & OFFICENORTHSIDE PUD(EXISTING)SD SD SD SDBIOSWALEBIOSWALE PATIOPATIO PATIOBIOSWALEBIOSWALE MAINT. SSC LANED LANE A LANE B LANEG LANEA LANE C LANE E LANESD SD SDSDSDSDSDSDSSSD SD SD109 E. OAK1285 N. ROUSESS SS SS SS SS SS105 E. OAK107 E. OAK115 E. OAK111 E. OAK117 E. OAK1237 N. ROUSE1251 N. ROUSEPROPERTY LINE1203 N. ROUSE113 E. OAKPROPERTY LINE 211 E. OAKPROPERTY LINEPROPERTY LINESS SS SS SDSDPATIO12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W 12''W 12''W 12''W 12''W<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<SSSDSDSDPROPERTY LINESSSDSDSDOAK STREETBLDG J11,9001+MEZZ13,400HEALTH & EXERCISESSSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<TRASHBLDG M11 SPACESBLDG L13 SPACES16 SPACES11 SPACES13 SPACES9 SPACES9 SPACES27 SPACESRAIL TRAILLOADINGRAIL TRAILPHASE 3BLDG L17,946461,621OFFICE w/RESIDENTIAL ABOVEBLDG M8,1652+BSMT22,176OFFICE w/BASEMENT STORAGEPARKING PLAZA20 SPACESE LANEF LANE231 E. OAK221 E. OAK5 SPACES10 SPACESRESERVED RESIDENTIALCOVERED PARKING RESERVED RES.COVERED PARKINGRESERVED RES.COVERED PARKINGRESERVED RESIDENTIALCOVERED PARKINGRESERVED RES.COMPACT. COV. PARKINGLOADINGBLDG O8,9501&318,524OFFICE, RESTAURANTTOTAL97,946203,363PH 1 SEWER MAINSAND SERVICES30' WIDE WATER-SEWER EASEMENTSBLDG M TO CONNECT TOBLDG D SERVICE. BLDG DTO GET RELOCATEDSERVICE AS SHOWN(DASHED GREEN)30' WIDE WATER-SEWER EASEMENTS30' WIDE WATER-SEWER EASEMENTSPROPOSED PHASE 3SERVICE (DASHED GREEN)CANNERY DISTRICTPHASE 3 EXTENTSIN FEETPROFESSIONALENGINEERS &SURVEYORSCANNERY DISTRICTPHASE 3 STAHLYENGINEERING& ASSOCIATESCANNERY DISTRICTPARTNERS, LLCSEWER SITEPLANFIGURE 2 Appendix TABLE 1:  Detailed Cannery District Water Usage 4/3/2019 Cannery District Phase 1 Area **Peak Hr Flow Use by Building (gsf)gpd/1000 sf GPD (ac‐ft/yr)(gpm) Cannery Building (Bldg E) Office/Retail 16,897 30 507 0.57 3.5 Restaurant/Bar 7,663 500 3,832 4.29 26.6 Building Common Area 3,773 30 113 0.13 0.8 Subtotal 28,333 4,452 4.99 30.9 Cannery Complex (Bldg F) Office/Retail 7,621 30 229 0.26 1.6 Restaurant/Bar 7,505 500 3,753 4.20 26.1 Building Common Area 625 30 19 0.02 0.1 Subtotal 15,751 4,000 4.48 27.8 Canning Warehouse (Bldg G) Office/Retail 14,041 30 421 0.47 2.9 Restaurant/Bar 1,365 500 683 0.76 4.7 Building Common Area 3,066 30 92 0.10 0.6 Subtotal 18,472 1,196 1.34 8.3 Boiler House (Bldg H) Office 2,100 30 63 0.07 0.44 Total of Phase 1 9,710 10.88 67.43 Cannery District Phase 2 Area **Peak Hr Flow Use by Building (gsf)gpd/1000 sf GPD (ac‐ft/yr)(gpm) Building J Office 1,500 30 45 0.05 0.3 Gym 11,900 100 1,190 1.33 8.3 Subtotal 13,400 1,235 1.38 8.6 Building K Office 3,245 30 97 0.11 0.7 Gym 4,607 100 461 0.52 3.2 Building Common Area 3,391 30 102 0.11 0.7 Subtotal 11,243 660 0.74 4.6 Total of Phase 2 1,895 2.12 13.2 Cannery District Phase 4 Area **Peak Hr Flow Use by Building (gsf)gpd/1000 sf GPD (ac‐ft/yr)(gpm) Bldg  N Office/Retail 8,712 30 261 0.29 1.8 Building Common Area 1,584 30 48 0.05 0.3 Subtotal 10,296 309 0.35 2.1 Bldg  O Office/Retail 14,378 30 431 0.48 3.0 Restaurant/Bar 1,642 500 821 0.92 5.7 Building Common Area 2,504 30 75 0.08 0.5 Subtotal 18,524 1,327 1.49 9.2 Total of Phase 4 1,636 1.83 11.4 Cannery District Phase 3 Area **Peak Hr Flow Use by Building (gsf)gpd/1000 sf GPD (ac‐ft/yr)(gpm) Bldg L Office/Retail 14,926 30 448 0.50 3.1 *Residential 7,142 8.00 49.6 Subtotal 7,590 8.50 52.7 Bldg M Office 21934 30 658 0.74 4.6 Total of Phase 3 8,248 9.24 57.3 TOTAL ALL PHASES 21,489 24.07 149.2 * Residential Use calculated using 89 gal/person/day, 80.25 estimated people ** Peaking Factor used for Avg Day to Peak Hour 10 Average Water Use Average Water Use Average Water Use Average Water Use