HomeMy WebLinkAbout2021-03-30_E5-2 - EXTERIOR LUMINAIRE SCHEDULE & DETAILSBase Cap Rotation lock set screws 180 degress apart, quantity two (2). Dual O-Ring Seal. Make sure sealing surface is kept clean. Grease o-rings with silicone grease. To allow for easy rotation and extended life of o-ring.Stability Plate Attachment Method Driver Slope surface to allow for run off Pea gravel back fill below and around sides of direct burial junction box for drainage. Recommended re-enterable potting seal material - 3M High Gel 4442 Recessed Direct Burial Junction Box Stability Plate Conduit plug. Recommed using gray duct sealing compund to completely seal wires inside conduit and conduit entries P CKT PER LTG PLAN CKT PER LTG PLAN ZONE 1 EMERGENCY LIGHTING EM INVERTER OUTDOOR NOTE: PROGRAM LIGHTING CONTACT FOR ALL EXTERIOR LUMINAIRES TO SWITCH ON/OFF VIA PHOTOCELL AND TIMECLOCK. COORDINATE TIMECLOCK SCHDULE WITH OWNER. LIGHTING CONTROL PANEL WITH PHOTOCELL AND INTEGRAL SYSTEM CLOCK WATTSTOPPER LC8-120/277V, OAE ZONE 2 ZONE 3 ZONE 4 BASE SIZE SEE SCHED.2'-6"HEIGHT AFGSEE SCHED.DEPTH *** - SEE SCHED. CONCRETE BASE SCHEDULE ***** POLE HT.BASE SIZE VERT. REINF. HORIZ. REINF. DEPTH *** HEIGHT AFG 0' TO 14' 15" SQ.(4) #6 *#3@10"O.C. 4'-0" 0'-6" 18" RND.(6) #5 **** #3@10"O.C. 4'-0" 0'-6" 14' TO 30' 20" SQ. (4) #7 * #3@12"O.C. 7'-0" 2'-6" 24" RND. (6) #6 **** #3@12" O.C. 7'-0" 2'-6" 35' TO 40'24" RND. (6) #6**** #3@12" O.C. 8'-6" 2'-6" ANCHOR BOLTS FROM POLE MANF. NOTE: HORIZ. REINF. SEE SCHEDULE HANDHOLE - 4" X 6" (NOMINAL) THWN CONDUCTOR AS SHOWN ON PLANS PROVIDE 1' OF COILED SLACK ON CONDUCTOR FEED THRU PROJECT ANCHOR BOLTS 3" MIN. ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). PROVIDE NON-SHRINK GROUT IN VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE, LEAVING DRAIN HOLE. HAND FINISH. CONNECT GROUND TO POLE BASE W/ BOUNDRY #GB4C PROVIDE FUSE(S) IN CKT. TO BALLAST. FUSE(S) SHALL BE BUSS TYP. BBS. FUSE HOLDERS SHALL BE BUSS "TRON" HEB WATERPROOF. SIZE OF FUSE SHALL BE AS REQUIRED BY LUMINAIRE MANUFACTURER. BASE COVER BUSH CONDUITS REINFORCED CONC. BASE BY ELECTRICAL CONTRACTOR 1" CHAMFER SEE SITE PLAN FOR CONDUIT SIZE FINISH GRADE. COMPACT SOIL IN 6" MAX LIFTS IN EXCAVATED AREA AROUND POLE FOUNDATION VERT. REINF. SEE SCHEDULE NOTE: • CONTRACTOR SHALL GRIND EXPOSED CONCRETE SMOOTH. EXPOSED CONCRETE SHALL HAVE NO SONOTUBE MARKINGS. • CONTRACTOR SHALL PREP EXPOSED BASE FOR EUCLID VERTICOAT. APPLY PER MANUFACTURER INSTRUCTIONS TO PROVIDE A FINSIHED APPEARANCE * PROVIDE VERTICAL BARS AT EACH CORNER OF SQ. PIER. ** PROVIDE SPACING OF S/3 AT TOP 1'-0" OF PIER. *** DEPTH BELOW FINISHED GRADE. **** SPACE VERTICAL BARS EVENLY AROUND PERIMETER. *****PROVIDE REINF. CLEARANCE PER ACI 318. 40' TO 55' 36" RND. (8) #6**** #3@12" O.C. 9'-0" 2'-6"20' - 0"E2 REVISIONS NOTES REVISIONS NOTES STAMP + SIGNATURE KEY PLAN Building A Building B SP1 03/30/2021 Energy 1 2042 Stadium Dr Suite 2 Bozeman, MT 59715 +1 406 587 2917 As indicated EXTERIOR LUMINAIRE SCHEDULE & DETAILS E5.2HAVENPond Row Lot 3A, Van Horn Subdivision Bozeman, MT 59715 E5.2 SCALE: 12" = 1'-0" EXTERIOR LIGHTING CONTROL DIAGRAM - LCP WITH INVERTER1 E5.2 SCALE: 1/2" = 1'-0" LIGHTED BOLLARD BASE DETAIL3 E5.2 SCALE: 1/8" = 1'-0" POLE LIGHT BASE DETAIL4 1. ALL EXTERIOR FIXTURES ARE REQUIRED TO BE FULL CUTOFF. B.U.G - U LEVEL TO BE 0. 2. ALL EXTERIOR FIXTURES TO BE 0-10V DIMMABLE AND HAVE A COLOR TEMP. OF 4000K.... EXTERIOR LUMINAIRE SCHEDULE Type Mark Wattage DESCRIPTION MANUFACTURER & MODEL E1 9 W EXTERIOR 2FT TALL PATHWAY LIGHT COOPER-303-P1-LEDB1-4000K-UNV-T2-DIM10-BZ-24-EDGE E2 54 W EXTERIOR POLE MOUNT AREA LIGHT COOPER - PRV-PA1-A-740-U-T3--BK-HSS E2H 54 W SAME AS E2 WITH HOUSE SIDE SHEILD LITHONIA-DSX1 LED -P1-40K-T3M-MVOLT-SPA-DMG-HS-DDBXD E4 8 W EXTERIOR LANDSCAPE ACCENT LIGHT COOPER-203-FL-8LED-40K-45-12-KZ-LVR EM1 EMERGENCY BATTERY INVERTER SURE-LITE - INV-600-SD-CA EX1 25 W EXTERIOR RECESSED DOWN LIGHT COOPER-LDSQ4B-30-D010 EX1E 25 W SAME AS EX1 TIED TO EMERGENCY BATTERY INVERTER COOPER-LDSQ4B-30-D010 EX2 12 W WALL MOUNTED CYLINDER UP/DOWN LIGHT (TO BE LOCATED UNDER EAVES ONLY) COOPER-9003-W1-RW-LED4080-W-BZ-L1-UNV-WRR-DIM10 EX2E 12 W SAME AS EX2 TIED TO EMERGENCY BATTERY INVERTER COOPER-9003-W1-RW-LED4080-W-BZ-L1-UNV-WRR-DIM10 EX3 12 W WALL MOUNTED CYLINDER DOWN LIGHT COOPER-9003-W2-RW-LED4080-W-M-BZ-L1-UNV-WRR-DIM10 E5.2 SCALE: 1/4" = 1'-0" POLE HEIGHT DETAIL2 No. Description Date