HomeMy WebLinkAbout2021-03-30_E0-1 - ELECTRICAL SYMBOLS & ABBREVIATIONSM M M SPD LA PFC M VFD G CB PNL A 208Y/120V3ø, 4W XX XJTV J PS-XXD-1 X X OS OS P LV OS LV OS LVP LC# LV S P S F S T H D SD SS CO D F FF SS WA CR RE DC ES EL MD GB C SC ELECTRICAL ABBREVIATIONS LEGEND A, AMP AMPERES AC ALTERNATING CURRENT A/C AIR CONDITIONING AF AMP FUSE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AL ALUMINUM AS AMP SWITCH ATS AUTOMATIC TRANSFER SWITCH BAS BUILDING AUTOMATION SYSTEM BKR BREAKER C RACEWAY/CONDUIT CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING C.O.RACEWAY/CONDUIT ONLY, WITH PULL STRING CNTRL CONTROL CU COPPER D EXISTING TO BE DEMOLISHED DISC DISCONNECT DIST DISTRIBUTION DPDT DOUBLE POLE DOUBLE THROW DWG DRAWING EA EACH EF EXHAUST FAN ELEC ELECTRIC EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EX, EXIST EXISTING FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FD FUSED DISCONNECT FLR FLOOR FO FIBER OPTIC FSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACP FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING GEC GROUNDED ELECTRODE CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPER GFI GROUND FAULT INTERRUPTER GFP GROUND FAULT PROTECTION GND GROUND GRC GALVANIZED RIGID CONDUIT HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSEPOWER HPS HIGH PRESSURE SODIUM HTR HEATER HVAC HEATING, VENTILATION & AIR CONDITIONING HZ HERTZ J-BOX JUNCTION BOX KVA KILOVOLT-AMPERES KW KILOWATTS LCP LIGHTING CONTROL PANEL LPW LUMENS PER WATT LTG LIGHTING LV LOW VOLTAGE MAG MAGNETIC STARTER MAN MANUAL MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MH METAL HALIDE MIN MINIMUM MSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADS N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFD NON-FUSED DISCONNECT NIC NOT IN CONTRACT NO NORMALLY OPEN #NUMBER OAE OR APPROVED EQUAL OC ON CENTER OCPD OVERCURRENT PROTECTIVE DEVICE OH OVERHEAD P POLE PB PUSHBUTTON PH PHASE PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT PWR POWER R EXISTING TO REMAIN RCPT RECEPTACLE RECEPT RECEPTACLE RGS RIGID GALVANIZED STEEL RM ROOM RVNR REDUCED VOLTAGE NON-REVERSING RVR REDUCED VOLTAGE REVERSING SP SINGLE POLE TOGGLE SWITCH SPD SURGE PROTECTIVE DEVICE (TVSS) SPEC SPECIFICATION SPST SINGLE POLE SINGLE THROW SSPB START-STOP PUSHBUTTON SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TB TELEPHONE BOARD TC TIME CLOCK TD TIME DELAY TEL TELEPHONE TSP TWISTED SHIELDED PAIR TTB TELEPHONE TERMINAL BOARD TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERES VFD VARIABLE FREQUENCY DRIVE W WATTS WP WEATHERPROOF W/O WITHOUT XFMR TRANSFORMER Y WYE-CONNECTED Δ DELTA-CONNECTED ø PHASE ELECTRICAL ONE-LINE LEGEND MOTOR SYMBOL CT AND CUSTOMER POWER METER UTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER) SURGE PROTECTION DEVICE LIGHTNING ARRESTOR STRESS RELIEF CONE POWER FACTOR CORRECTION CAPACITOR MOTOR STARTER SWITCH W/ THERMAL OVERLOADS CONTACTOR NORMALLY OPEN, NORMALLY CLOSED TRANSFORMER, 3-PH, 3-WIRE DELTA CONNECTION TRANSFORMER, 3-PH, 4-WIRE GROUNDED WYE CONNECTION AUTOMATIC TRANSFER SWITCH VARIABLE FREQUENCY DRIVE FIXED MOUNT LV BREAKER FUSED SWITCH ("XXAS/XXAF" - SW AND FUSE AMP RATING) GENERATOR WALL MOUNTED BREAKER THERMAL OVERLOAD ELEMENT DISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING) FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING) COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE) SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED ELECTRICAL POWER LEGEND PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER). BRANCH CIRCUIT WIRE SIZE IS #12, UNO. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT CIRCUITING, SEE MEP COORDINATION SCHEDULE. "X" INDICATES TYPE: GFI - GROUND FAULT INTERRUPTER WP/GFI - EXTERIOR WEATHERPROOF GFI RECEPTACLE WITH WHILE-IN-USE COVER; COLE LIGHTING TL210-WCS-NK OAE. U - PROVIDE WITH (2) USB PORTS; (1) STANDARD & (1) USB C PANELBOARD OR LOAD CENTER JUNCTION BOX FLATSCREEN TV BOX: 2-GANG, RECEPTACLE & SINGLE GANG DATA PORT. COORDINATE EACH LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. SIMPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) DUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) QUADRUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) FLOOR BOX WITH QUADRUPLEX RECEPTACLE - WITH (2) TELE/DATA PORTS, WITHOUT TELE/DATA. INCLUDE ALL HARDWARE/ACCESSORIES AS REQUIRED. PROVIDE COVER (COORDINATE WITH ARCHITECT FOR FLOORING TYPE AND FINISH). SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO) "X" INDICATES TYPE: A - NEMA 5-20R, #12 CU; B - NEMA 5-30R, #10 CU; C - NEMA 5-50R, #8 CU; D - NEMA 6-20R, #12 CU; E - NEMA 6-30R, #10 CU; F - NEMA 6-50R, #8 CU; G - NEMA 14-20R, #12 CU; H - NEMA 14-30R, #10 CU; I - NEMA 14-50R, #8 CU DROP-DOWN RECEPTACLE SURFACE MOUNTED PLUGSTRIP "X" INDICATES TYPE: A - PLUGSTRIP, POWER ONLY, OUTLET EVERY 3' OC B - WIREMOLD SERIES 4000 POWER AND DATA C - WIREMOLD SERIES 5000 POWER AND DATA SURFACE MOUNTED RACEWAY RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACES RACEWAY BELOW FLOOR OR BELOW GRADE RACEWAY STUB-OUT WITH CAPPED END RACEWAY STUB-OUT WITH BRUSHED END GROUNDING BUS PUSHBUTTON (MOUNT AT +46", UNO) "X" INDICATES TYPE: EPO - EMERGENCY POWER OFF ADA - HANDICAPPED ACCESSIBLE DOOR (DEVICE BY OTHERS) ODO - OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS) "X" INDICATES TYPE: A - 4-GANG FLOOR BOX, CORROSION RESISTANT COATING FOR CONCRETE FLOORS (3" MIN. POUR DEPTH), UP TO 2" CONDUIT FEED (HUBBELL NO. CFB4G30CR, OAE) B - 4-GANG FLOOR BOX FOR RAISED ACCESS FLOORS, UP TO 2" CONDUIT FEED (HUBBELL NO. AFB4G50, OAE) C - FIRE RATED POKE-THROUGH FLOOR BOX FOR ELEVATED CONCRETE SLABS, 3" DIA. CORE (HUBBELL NO. PT7FSD, OAE) D - 8" DIA., FIRE RATED POKE-THROUGH FLOOR BOX FOR ELEVATED CONCRETE SLABS, UP TO 2" CONDUIT FEED (HUBBELL NO. S1R8PTFIT3, OAE) E - FLUSH, ROUND SINGLE SURFACE FLOOR BOX FOR CONCRETE FLOORS, UP TO 1" CONDUIT FEED (HUBBELL NO. B2506, OAE) F - TOMBSTONE PEDESTAL FLOOR BOX, 1" CONDUIT FEED (HUBBELL NO. 6301, OAE) ABOVE COUNTER RECEPTACLE - MOUNT AT +4" ABOVE BACKSPLASH ELECTRICAL PROJECT NOTES A. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET. C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG. D. DURING DEMOLITION, THE CONTRACTOR SHALL NOTE ALL EXISTING RACEWAY (BOTH SURFACE AND CONCEALED) TO THE EXTENT POSSIBLE. THESE RACEWAYS SHALL BE REUSED TO THE GREATEST EXTENT POSSIBLE TO INSURE A CLEAN FINISHED PRODUCT. WHERE PRACTICAL, AND ALLOWED PER CODE, FISHING THROUGH WALLS WITH MC CABLE IS PREFERRED TO SURFACE-MOUNTED CONDUIT. E. CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OF LAMPS AND BALLASTS OFF-SITE. IT IS ASSUMED THE THE BALLASTS DO NOT CONTAIN PCBs. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF IT IS SUSPECTED THAT BALLASTS CONTAIN PCBs. F. ALL POWER INTERRUPTIONS SHALL BE COORDINATED WITH OWNER. ANY DISRUPTION OF WORKERS IN THE SPACE SHALL BE KEPT TO A MINIMUM AND BE COORDINATED WITH THE OWNER PRIOR TO WORK COMMENCING IN THAT SPACE. G. CONTRACTOR SHALL EXTEND UNSWITCHED HOT LEG FROM EXISTING EMERGENCY FIXTURE LOCATION TO NEW EMERGENCY FIXTURES. AS NEEDED. SEE DEMO PLANS FOR AN APPROXIMATION OF EXISTING EMERGENCY FIXTURE LOCATIONS. FIELD VERIFY EXACT LOCATION PRIOR TO BID. H. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS. I. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE- RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES. J. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C. K. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3% OR LESS. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AMG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED. L. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT. ELECTRICAL LIGHTING CONTROL LEGEND OCCUPANCY SENSOR - CEILING MOUNT, WALL MOUNT. CRESTRON GLS-ODT-C-CN, OR EQUAL TOGGLE SWITCH (MOUNT AT +46", UNO) "X" INDICATES TYPE: BLANK - SINGLE POLE 3 - INDICATES THREE-WAY 4 - INDICATES FOUR-WAY D - INDICATES DIMMER SWITCH PHILIPS SUNRISE - ON/OFF K - INDICATES KEYED SWITCH T - INDICATES TIMER P - INDICATES PILOT LIGHT OCC - INDICATES WALL SWITCH OCC SENSOR CRESTRON GLA-DT-VS-1-W, OR EQUAL a - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a b - INDICATES SINGLE POLE LIGHTING SIWTCH ZONE FOR ZONE b ab - INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES OCCUPANCY SENSOR - CEILING MOUNT, WALL MOUNT CRESTRON GLS-ODT-C-CN, OR EQUAL PHOTOCELL - CEILING MOUNT CRESTRON GLA-LDL-PC-0-10, OR EQUAL PHOTOCELL - CEILING MOUNT, CRESTRON GLA-LDL-PC-0-10, OR EQUAL STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS DIGITAL LIGHTING CONTROLS: ROOM CONTROLLERS AND LOW VOLTAGE DEVICES ON/OFF ROOM CONTROLLER WITH (4) RELAYS CRESTRON GREEN LIGHT GLPAC-DIMFLV4, OR EQUAL LOW VOLTAGE SWITCH CRESTRON GLPPA-KP-W-S, OR EQUAL LC-#TAG COORDINATING THE ROOM CONTROLLER ASSOCATED TO PARTICULAR LIGHT FIXURE. ELECTRICAL LIGHTING FIXTURE LEGEND RECESSED LED FIXTURE - "a" & "b" DESIGNATES SWITCH EXIT SIGN - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. RECESSED EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE WALL MOUNT LED FIXTURE LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG EMERGENCY LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG POLE MOUNTED FIXTURE LIGHTED BOLLARD PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE DUAL HEAD EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR CEILING MOUNT WALL MOUNTED SCONCE SURFACE DOWNLIGHT SURFACE EMERGENCY DOWNLIGHT RECESSED CAN DOWNLIGHT RECESSED CAN EMERGENCY DOWNLIGHT RECESSED CAN WALL WASHER TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTING PLANS. ELECTRICAL LOW VOLTAGE LEGEND FIRE ALARM SYSTEM TELEPHONE/DATA SYSTEM SPRINKLER PRESSURE SWITCH SPRINKLER FLOW SWITCH SPRINKLER TAMPER SWITCH HEAT DETECTOR DUCT SMOKE DETECTOR SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND MONITOR AT FACP VIA RELAY. CARBON MONOXIDE DETECTOR DOOR HOLDER MANUAL STATION (MOUNT AT +46", UNO) STROBE - WALL MOUNT (+90"), CEILING MOUNT HORN/STROBE - WALL MOUNT (+90"), CEILING MOUNT SPEAKER STROBE - WALL MOUNT (+90"), CEILING MOUNT DUAL TEL/DATA DROP (MOUNT AT +18", UNO). SEE NOTE. SINGLE TEL/DATA DROP (MOUNT AT +18", UNO). SEE NOTE. FLATSCREEN TV BOX; 2-GANG, FLUSH IN WALL, HUBBELL RACO NSAV62M WITH NSAV6C COVER. DUPLEX RECEPTACLE AND SINGLE GANG DATA PORT. (MOUNT AT +72" AFF. UNO.) WIRELESS ACCESS POINT (TO BE PROVIDED WITH POWER) CABLE TRAY OR BASKET TRAY - LENGTH AND HEIGHT PER PLAN SECURITY SYSTEM CARD READER - SEE ELECTRICAL DETAILS FOR ROUGH-IN (MOUNT AT +46", OR MATCH ADJACENT DOOR ACCESS CONTROL) REQUEST TO EXIT MOTION DETECTOR DOOR CONTACTS ELECTRIC STRIKE ELECTRIC LOCK MOTION DETECTOR GLASS BREAK DETECTOR CCTV CAMERA - CEILING MOUNT OR WALL MOUNT. SEE NOTE. NOTE: PROVIDE ROUGH-IN ONLY. SINGLE GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE. NOTE: PROVIDE ROUGH-IN ONLY. 2-GANG BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE. COMBO SMOKE DETECTOR & CARBON MONOXIDE DETECTOR - PHOTO-ELECTRIC. UL 268 TV REVISIONS NOTES REVISIONS NOTES STAMP + SIGNATURE KEY PLAN Building A Building B SP1 03/30/2021 Energy 1 2042 Stadium Dr Suite 2 Bozeman, MT 59715 +1 406 587 2917 12" = 1'-0"ELECTRICAL SYMBOLS & ABBREVIATIONS E0.1HAVENPond Row Lot 3A, Van Horn Subdivision Bozeman, MT 59715 No. Description Date