Loading...
HomeMy WebLinkAbout2021-03-30_C9.4 STORM DRAIN DETAILSSHEETOFDATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 ADVANCED DRAINAGE SYSTEMS, INC. REV DRW CHK DESCRIPTION SB #1 HAVEN Bozeman, MT 03/03/2021 JZ Tool5 5--- 70 INWOOD ROAD, SUITE 3 | ROCKY HILL | CT | 06067 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water QualityPART #STUBABCSC310EPE06T /SC310EPE06TPC6" (150 mm)9.6" (244mm)5.8" (147 mm)---SC310EPE06B / SC310EPE06BPC---0.5" (13 mm)SC310EPE08T / SC310EPE08TPC8" (200 mm)11.9" (302 mm)3.5" (89 mm)---SC310EPE08B / SC310EPE08BPC---0.6" (15 mm)SC310EPE10T / SC310EPE10TPC10" (250 mm)12.7" (323 mm)1.4" (36 mm)---SC310EPE10B / SC310EPE10BPC---0.7" (18 mm)SC310EPE12B12" (300 mm)13.5" (343 mm)---0.9" (23 mm)ALL STUBS, EXCEPT FOR THE SC310EPE12B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OFTHE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT1-888-892-2694.* FOR THE SC310EPE12B THE 12" (300 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 0.25" (6 mm).BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.NOTE: ALL DIMENSIONS ARE NOMINALNOMINAL CHAMBER SPECIFICATIONSSIZE (W X H X INSTALLED LENGTH)34.0" X 16.0" X 85.4" (864 mm X 406 mm X 2169 mm)CHAMBER STORAGE14.7 CUBIC FEET (0.42 m³)MINIMUM INSTALLED STORAGE*31.0 CUBIC FEET (0.88 m³)WEIGHT35.0 lbs.(16.8 kg)*ASSUMES 6" (152 mm) ABOVE, BELOW, AND BETWEEN CHAMBERSSTUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"34.0"(864 mm)16.0"(406 mm)90.7" (2304 mm) ACTUAL LENGTH85.4" (2169 mm) INSTALLED LENGTHACCEPTS 4" (100 mm) SCH 40 PVCPIPE FOR INSPECTION PORT. FORPIPE SIZES LARGER THAN 4" (100 mm)UP TO 10" (250 mm) USE INSERTA TEECONNECTION CENTERED ON ACHAMBER CREST CORRUGATIONOVERLAP NEXT CHAMBER HERE(OVER SMALL CORRUGATION)BUILD ROW IN THIS DIRECTIONSTART ENDAABCSC-310 TECHNICAL SPECIFICATIONNTS9.9"(251 mm)45.9"(1166 mm)15.6"(396 mm)INSERTA TEE DETAILNTSINSERTA TEECONNECTIONCONVEYANCE PIPEMATERIAL MAY VARY(PVC, HDPE, ETC.)PLACE ADS GEOSYNTHETICS 315 WOVENGEOTEXTILE (CENTERED ON INSERTA-TEEINLET) OVER BEDDING STONE FOR SCOURPROTECTION AT SIDE INLET CONNECTIONS.GEOTEXTILE MUST EXTEND 6" (150 mm)PAST CHAMBER FOOTINSERTA TEE TO BEINSTALLED, CENTEREDOVER CORRUGATIONSIDE VIEWSECTION A-AAADO NOT INSTALLINSERTA-TEE ATCHAMBER JOINTSNOTE:PART NUMBERS WILL VARY BASED ON INLET PIPE MATERIALS.CONTACT STORMTECH FOR MORE INFORMATION.CHAMBERMAX DIAMETER OFINSERTA TEEHEIGHT FROM BASE OFCHAMBER (X)SC-3106" (150 mm)4" (100 mm)SC-74010" (250 mm)4" (100 mm)DC-78010" (250 mm)4" (100 mm)MC-350012" (300 mm)6" (150 mm)MC-450012" (300 mm)8" (200 mm)INSERTA TEE FITTINGS AVAILABLE FOR SDR 26, SDR 35, SCH 40 IPSGASKETED & SOLVENT WELD, N-12, HP STORM, C-900 OR DUCTILE IRON(X)INTENTIONALLYLEFT BLANKTRUE NORTHREVISIONSNOTESREVISIONSNOTESSTAMP + SIGNATUREKEY PLANNo.DescriptionDateSanderson StewartBozeman,MT 59715Building ABuilding BSP103/30/2021HAVEN SITE PLANSUBMITTAL106 East Babcock, Suite L1Pond RowLot 3A, Van Horn SubdivisionBozeman, MT 59715STORM DRAINDETAILSC9.4