HomeMy WebLinkAbout2021-03-30_ L5-04 - SECURITY DETAILSINTERIOR SECTIONGATE PLANCEDAR FENCE, REFER TO DETAIL 2/L5.04 FOR ADDITIONAL INFORMATION4" DIAMETER STEEL POLES FOR BRACINGNYLON ROLLERS WITHIN TRACKSEE CIVILS FOR PARKING LOT BUILD UPLIFTMASTER BASE TO BE IN INTERIOR OF PARKING LOT6' - 0"0' - 2"0' - 6"0' - 6" 10' - 0" TYP.2 3/8" SCHEDULE 40 GALVANIZED PIPE,WELDED TOGETHER6' - 0"8' - 0"0' - 4"3 HORIZONTAL BOARDS, 7/8" CEDAR BOARD4' - 5 1/4"INTERIOR SECTIONEXTERIOR ELEVATION2 3/8" SCHEDULE 40 GALVANIZED PIPE6 0 .0 0 °0' - 0 1/2" TYP.0' - 5 1/8" TYP.PLANTING SPP. TO BE SCREENING METHOD ON MAJORITY OF SURROUNDING FENCE, SEE PLAN0' - 2"IF REQUIRED, DIVISION OF BOARD LENGTHS TO BE CUT IN THE MIDDLEL5.044SimFASTEN PIPE TO RAIL WITH PIPE GRIP TIE,SIMPOSON STRONG-TIE PGT AND 1/4" LAG BOLTS, OR SIMILAR APPROVED ATTACHMENTIF REQUIRED, DIVISION OF BOARD LENGTHS TO BE CUT IN THE MIDDLEINTERIOR SECTIONGATE PLANCEDAR FENCE, REFER TO DETAIL 2/L5.04 FOR TYPICAL INFORMATION2 3/8" SCHEDULE 40 GALVANIZED PIPE,WELDED FOR BRACING4" DIAMETER STEEL POLES FOR BRACING, 4' POUNDED INTO GROUNDNOTE: AUTOMATED FIRE KNOX BOX ZINC PLATED 1-WAY LOCKABLE GATE LATCH BRACKET SET OR SIMILAR TO BE APPROVED BY LANDSCAPE ARCHITECTSEE CIVILS FOR PARKING LOT BUILD UPKNOX BOXEXTERIOR ELEVATIONKNOX BOX, TO BEATTACHED AS PER MANUFACTURERS INSTRUCTIONS0' - 4"5' - 5"GATE OPENINGFENCE STARTHEAVY DUTY GATE WHEELS TO BE ATTACHED PER MANUFACTURES INSTRUCTIONS, TO BE APPROVED BY LANDSCAPE ARCHITECT 0' - 8"0' - 6" 0' - 6"1' - 4 1/32"4" DIAMETER STEEL POLES 10' - 0"ZINC PLATED 1-WAY LOCKABLE GATE LATCH AND BRACKET SET OR SIMILAR TO BE APPROVED BY LANDSCAPE ARCHITECT6' - 0"2 3/8" SCHEDULE 40 GALVANIZED PIPE TO BE POUNDED INTO GROUND90.00°4' - 0"INTERIOR SECTIONGATE PLANCEDAR FENCE, REFER TO DETAIL 2/L5.04 FOR ADDITIONAL INFORMATION7/8" THICK, HORIZONTAL BOARDS2 3/8" SCHEDULE 40 GALVANIZED PIPEGATE CANE BOLT, 5/8" X 18", LOCKABLECEDAR FENCE, REFER TO DETAIL 2/L5.04 FOR ADDITIONAL INFORMATIONSEE CIVILS FOR PAVING BUILD UPFASTEN PIPE TO RAIL WITH PIPE GRIP TIE,SIMPSON STRONG-TIE PGT AND 1/4" LAG BOLTS, OR SIMILAR APPROVED ATTACHMENT0' - 6"0' - 6"3' - 3 7/16"PIPE TO EXTEND 4' INTO THE GROUND,NO CONCRETE NEEDED 5' - 0"6' - 0"4' - 2"1' - 9"0' - 7 29/32"0' - 3 3/4"TRUE NORTHREVISIONSNOTESREVISIONSNOTESSTAMP + SIGNATUREKEY PLANBuilding ABuilding BSP13/30/31As indicatedSECURITY DETAILSL5.04HAVENPond RowLot 3A, Van Horn SubdivisionBozeman, MT 59715MASS Design GroupPO Box 212Bozeman, MT 597711/2" = 1'-0"1G1 Survivors Parking Lot Gate1/2" = 1'-0"2F1 Fence Typical1/2" = 1'-0"3G2 Fire Department Gate1 1/2" = 1'-0"4Fence Typical Footing1/2" = 1'-0"5G3 Pedestrian GateNo. Description Date