Loading...
HomeMy WebLinkAbout01_MEP 0-00 - MEP SITE SUBMITTAL COVER SHEET (11X17)_11-13-20REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT,AND FIXTURE TYPE.ROUND LIGHT FIXTURE (BOLLARD/CANOPY FIXTURES)POLE LIGHT 1 HEAD WITH POLEINDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE.EQUIPMENT CABINET, SURFACE MOUNTEDPANELBOARD. SEE SCHEDULE FOR TYPE.PAD MOUNT TRANSFORMERTTBTELEPHONE TERMINAL BOARDMEP0.00MEP SITE SUBMITTAL COVER SHEETE1.00ELECTRICAL SITE PLANE1.01ELECTRICAL SITE PHOTOMETRIC PLANP1.00PLUMBING SITE UTILITY PLANXXXELECTRICAL LEGENDMEP SHEET INDEXAAMPERESAC6" ABOVE BACKSPLASHAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEAFAMP FRAMEAICAMPS INTERRUPTING CAPACITYATAMP TRIPATSAUTOMATIC TRANSFER SWITCHAWGAMERICAN WIRE GAUGEBDBOTTOM OF DECKBSBOTTOM OF STRUCTURECCEILING MOUNTEDCCONDUITCBCIRCUIT BREAKERCFCOMPACT FLUORESCENTCKTCIRCUITCOCONDUIT ONLY, PROVIDE PULL-LINECTCURRENT TRANSFORMERCTLCONTROLDCDIRECT CURRENT(D)DEMOLITIONDEMODEMOLITIONDETDETAILDTTDOUBLE TWIN TUBEEEMERGENCY(E)EXISTINGECELECTRICAL CONTRACTORELEMERGENCY LIGHTFFUSE(F)FUTUREFACPFIRE ALARM CONTROL PANELG/GNDGROUNDGFCIGROUND FAULT CIRCUIT INTERRUPTERGFIGROUND FAULT INTERRUPTERHHHAND HOLEHIDHIGH INTENSITY DISCHARGEHOAHAND-OFF-AUTOHPSHIGH PRESSURE SODIUMHVACHEATING, VENTILATION, & AIR CONDITIONINGIGISOLATED GROUNDIPCOIDAHO POWER COMPANYJ-BOXJUNCTION BOXKAKILOAMPKVAKILO VOLT-AMPKWKILOWATTKWHKILOWATT HOURLCPLIGHTING CONTROL PANELMBMAIN BREAKERMBRMAIN CIRCUIT BREAKERMCCMOTOR CONTROL CENTERMDPMAIN DISTRIBUTION PANELMLOMAIN LUGS ONLYMMCMODULAR METERING CENTERMHMETAL HALIDEMSBMAIN SWITCH BOARDMTGMOUNTINGNNEUTRAL(N)NEWNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENICNOT IN CONTRACTNLNIGHT LIGHTNONORMALLY OPENNTSNOT TO SCALEOHOVERHEADOSOCCUPANCY SENSORPPOLESPCPHOTO-CONTROLPVCPOLYVINYL CHLORIDEPWRPOWERRE:REFERENCERECRECEPTACLE(R)RELOCATEDSFSQUARE FEETTBDTO BE DETERMINEDTDRTIME DELAY RELAYTKTOE KICKTSPTWISTED SHIELDED PAIRTRTTRIPLE TUBETTBTELEPHONE TERMINAL BOARD(TYP.)TYPICALUCUNDERCABINETUGUNDERGROUNDU.N.O.UNLESS NOTED OTHERWISEVVOLTVAVOLT-AMPEREWWATTWGWIRE GUARDWPWEATHER PROOF/NEMA 3RELECTRICAL ABBREVIATIONSPROVIDED/ PROVIDE BY INSTALLED/ INSTALLPROVIDE AND INSTALL / PROVIDED AND INSTALLED BY / PROVIDE AND INSTALLNOTE:THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOMEOF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWINGPACKAGE.NOTE:THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL SYMBOLS. SOMEOF THE SYMBOLS SHOWN MAY NOT HAVE BEEN USED IN THIS DRAWINGPACKAGE.BEGINNING OF INDIVIDUALCIRCUIT(S), CIRCUIT NUMBER(S)INDICATED.EMERGENCY SOURCEEXISTINGCONDUIT DOWNCONDUIT UP6NEUTRAL CONDUCTORSGROUNDING CONDUCTORSIZEQUANTITY1"-4#10,1#10GPANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO)RACEWAYDESIGNATES CIRCUIT ON CONDUIT, STUBBED, CAPPED AND MARKEDWITH PULL CORD AS SPECIFIEDA-2,4,6PANEL NAMECIRCUIT #EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED.EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUALDEDICATED NEUTRAL CONDUCTOR.CONCEALED INFLOOR ORUNDERGROUNDEMNOTE:JJJJJJCIRCUITING SYMBOLSUNMARKED CIRCUITIS CONCEALED IN CEILING OR WALL.MAINTAIN CONDUIT AND CONDUCTORSIZE THROUGHOUT ENTIRE CIRCUIT.CURRENT CARRYINGCONDUCTORSMECHANICAL AND PLUMBING DRAWINGSLEGENDFLEXIBLE DUCTWORKTHREE WAY CONTROL VALVEDUCTWORKTWO WAY CONTROL VALVEDUCTWORK BREAKPRESSURE REDUCING VALVEDUCTWORK OR PIPING RISEGATE VALVECONCENTRIC SQUARE TO ROUNDTRANSITIONREDUCERMOTORIZED DAMPERGLOBE VALVEMANUAL VOLUME DAMPERBALL VALVESPIN-IN FITTING W/ AIR EXTRACTOR ANDHAND DAMPERBUTTERFLY VALVEHIGH EFFICIENCY FITTING W/ HAND DAMPERBALANCE VALVESWITCHCHECK VALVETHERMOSTATFLOOR CLEANOUTHUMIDISTATWALL CLEANOUTTEMPERATURE SENSORGRADE CLEANOUTCARBON DIOXIDE SENSORWATER HAMMER ARRESTORCARBON MONOXIDE SENSORFLOOR DRAINNITROUS OXIDE SENSORFLOOR SINKDUCT SMOKE DETECTORGAS PRESSURE REGULATOR W/ GAS COCKCOMBINATION SMOKE/FIRE DAMPERPRESSURE RELIEF VALVEFIRE DAMPERVENT-THROUGH-ROOFSMOKE DAMPERVENTEQUIPMENT CALLOUTSOIL, WASTE, OR SANITARY SEWERTURNING VANESACID WASTE LINEINTAKE OR EXHAUSTACID VENT LINEDIRECTION OF AIRFLOWSTORM DRAINSUPPLY DIFFUSERROOF DRAIN LINERETURN GRILLEOVERFLOW DRAIN LINEEXHAUST GRILLECONDENSATE DRAIN LINEFLOOR GRILLEDOMESTIC COLD WATER (CW)CEILING EXHAUST FANDOMESTIC HOT WATER (HW)TEMPERATURE GAUGEDOMESTIC HOT WATER RETURN (HWR)PRESSURE GAUGE (LIQUID FILLED W/ISOLATION VALVE)TEMPERED WATER (TW)TEMPERATURE SENSOR (DUCT OR PIPING)MEDIUM PRESSURE NATURAL GASFLOW SWITCHLOW PRESSURE NATURAL GASSTAINLESS STEEL BRAIDED FLEXCONNECTIONFIRE SPRINKLER LINEELASTOMETRIC FLEX CONNECTORGEOTHERMAL WATER SUPPLYSUCTION DIFFUSERGEOTHERMAL WATER RETURNY TYPE STRAINER (1 1/2" OR LARGERPROVIDED W/ BLOW DOWN VALVE)CHILLED WATER SUPPLYFLOW DIRECTIONCHILLED WATER RETURNDEMOLITION / EQUIPMENT TO BE REMOVEDCONDENSER WATER SUPPLYNEW TO EXISTING CONNECTION POINTCONDENSER WATER RETURN(E)EXISTINGHEATING WATER SUPPLY(F)FUTUREHEATING WATER RETURN(N)NEWLIQUID REFRIGERANT LINEREDUCED PRESSURE BACKFLOWPREVENTERSUCTION REFRIGERANT LINEDOUBLE CHECK BACKFLOW PREVENTERSLOPE PIPE IN DIRECTION OF ARROWUNIONPIPE ANCHORAIR VENTPIPE GUIDETRIPLE DUTY VALVECAPNOTE:THIS IS A LIST OF COMMONLY USED MECHANICAL AND PLUMBING SYMBOLS. SOME OF THE SYMBOLS SHOWN ABOVEMAY NOT BE USED IN THIS DRAWING PACKAGE.MAIRFLOWAIRFLOWSTFCOHWCOSGCOCO2CONOSD--#AWAVSDD-XCFMX"ØRDR-XX"ØODR-XCFMX"ØCDG-XCFMX"ØTWTSMPGFSGFGWSGWRCWSCWRCSCRHWSHWRLSMECHANICAL GENERAL NOTES1.ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED INACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE (IMC) LATESTEDITION, AND ALL LOCAL & STATE CODES.2.ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE INSTALLED INACCORDANCE WITH THE LATEST ADOPTED PLUMBING CODE, AND ALL LOCAL& STATE CODES.3.ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER THEMANUFACTURER'S RECOMMENDATIONS.4.MECHANICAL CONTRACTORS SHALL RECEIVE PRIOR APPROVAL FROM THESTRUCTURAL ENGINEER BEFORE MAKING CUTS THROUGH ANY STRUCTURALMEMBER.5.MECHANICAL CONTRACTORS SHALL COORDINATE INSTALLATION WITHCONSTRUCTION SUPERVISOR AND WITH ALL OTHER TRADES TO AVOIDCONFLICTS.6.THE MECHANICAL CONTRACTORS SHALL VERIFY MOTOR VOLTAGES WITHTHE ELECTRICAL DRAWINGS BEFORE ORDERING MOTORIZED EQUIPMENTAND CONTROLS.7.SEE MECHANICAL SCHEDULE SHEET FOR SCHEDULED CAPACITIES OF ALLMECHANICAL EQUIPMENT AND MATERIALS SPECIFIED.8.DOMESTIC WATER SERVICE IS PROVIDED WITH A DOUBLE CHECK BACKFLOWPREVENTER.9.ALL MECHANICAL EQUIPMENT TO BE PROPOSED MUST BE ON THE APPROVEDLIST PRIOR TO SUBMITTALS. ALL APPROVED MANUFACTURERS MUST BECAPABLE OF MEETING THE REQUIREMENTS OF THE SPECIFIED EQUIPMENT.10.RUNOUT AND HOOKUP SIZES TO INDIVIDUAL PLUMBING FIXTURE CAN BEFOUND ON THE PLUMBING FIXTURE SCHEDULE.11.PROVIDE REMOTE CEILING ACCESS BALANCE DAMPERS WITH CONCEALEDCHROME PLATE COVERS FOR BALANCE DAMPERS LOCATED ABOVE HARDCEILINGS.12.PAINT ALL VTR'S, FLUES, EXHAUST CAPS, AND OTHER MECHANICAL ITEMS ONTHE ROOF TO MATCH THE ROOF COLOR.13.INSULATED FLEXIBLE DUCTWORK MAY BE USED FOR RUNOUTS TO GRILLESAND DIFFUSERS, IN LENGTHS OF 6'-0" OR LESS.14.MAINTAIN MINIMUM OF 10'-0" DISTANCE BETWEEN ALL FRESH AIR INTAKESAND EXHAUST OR GAS FLUE DISCHARGES.15.THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL BACKFLOW DEVICESTO BE INSPECTED BY A CERTIFIED BACKFLOW TECHNICIAN BEFORE THE USEOF THE BUILDING POTABLE WATER SYSTEM.16.LOCATE ACCESS HATCHES SO AS TO PROVIDE OPTIMUM SERVICEABILITY TOEQUIPMENT AND/OR VALVING. SEE ARCHITECTURAL SPECIFICATION FORTYPE AND COLOR. COORDINATE LOCATION WITH STRUCTURAL & LIGHTING.17.WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZESHOWN ON THE PLANS AND THAT SHOWN IN THE SCHEDULE, ALWAYS USETHE LARGER OF THE TWO DUCT SIZES.MECHANICAL ABBREVIATIONSA/C or ACAIR CONDITIONINGKWKILOWATTAFFABOVE FINISHED FLOORKWHKILOWATT HOURAHUAIR HANDLING UNITASHRAEAMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIRCONDITIONING ENGINEERSLATLEAVING AIR TEMPERATURELAVLAVATORYBTUBRITISH THERMAL UNITSLEEDLEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGNBTUHBTUS PER HOURLWTLEAVING WATER TEMPERATURECACOMBUSTION AIRMAXMAXIMUMCCCOOLING COILMCAMINIMUM CIRCUIT AMPSCFMAIR FLOW RATE (CUBIC FEET PER MINUTE)MOCPMAXIMUM OVERCURRENT PROTECTIONCHWRCHILLED WATER RETURNMINMINIMUMCHWSCHILLED WATER SUPPLYCLGCEILINGNCNOISE CRITERIACWCOLD WATERNFPANATIONAL FIRE PROTECTION ASSOCIATIONNTSNOT TO SCALEDEG or °DEGREEDIA or ØDIAMETEROSAOUTSIDE AIRDBDRY BULBPDPRESSURE DROPEAEXHAUST AIRPH or ØPHASEEATENTERING AIR TEMPERATUREPRVPRESSURE REDUCING VALVEEERENERGY EFFICIENCY RATIOESPEXTERNAL STATIC PRESSURERARETURN AIREWTENTERING WATER TEMPERATURERPMREVOLUTIONS PER MINUTERTUROOFTOP UNITFCOFLOOR CLEANOUTFDFIRE DAMPERSASUPPLY AIRFLAFULL LOAD AMPSSEERSEASONAL ENERGY EFFICIENCY RATIOFLRFLOORSFDCOMBINATION SMOKE/FIRE DAMPERFPMFEET PER MINUTESPSTATIC PRESSUREFTFEETSYMSYMBOLGAGAUGET & PTEMPERATURE AND PRESSUREGCOGRADE CLEANOUTTEMPTEMPERATUREGPMWATER FLOW RATE (GALLONS PER MINUTE)TYPTYPICALHCHEATING COILUMCUNIFORM MECHANICAL CODEHPHORSE POWERUPCUNIFORM PLUMBING CODEHVACHEATING, VENTILATING, AIR CONDITIONING URLURINALHWHOT WATERHWRHOT WATER RETURNVTRVENT THROUGH ROOFHWSHOT WATER SUPPLYVVOLTSIBCINTERNATIONAL BUILDING CODEW/WITHIEECINTERNATIONAL ENERGY CONSERVATION CODEWBWET-BULBIFCINTERNATIONAL FIRE CODEWCWATER CLOSETIFGCINTERNATIONAL FUEL GAS CODEWCOWALL CLEANOUTIMCINTERNATIONAL MECHANICAL CODEWHWATER HEATERIPCINTERNATIONAL PLUMBING CODENOTE:THIS IS A STANDARD LIST OF COMMONLY USED MECHANICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOTBE USED IN THIS DRAWING PACKAGE.REVIEW SUBMITTAL DEVELOPMENTDATE05-29-1916206SHEET NUMBERAPARTMENT UNITS IN BOZEMAN, MONTANA FARRAN REALTY PARTNERSPROJECTBOZEMAN EAST MIXED-USE 4202 BELTWAY DRIVE ADDISON, TX 75001 hedk.com214.520.8878 Engineering 1800 RIVER DR. NO. • GREAT FALLS, MONTANA 59401 406.761.3010 • tdhengineering.com TD&H PROJECT NO: 16-268 REV DATE 02.14.20 REVISION CITY COMMENTS01 07.31.20 CITY COMMENTS02 11.13.20 CITY COMMENTS03MEP0-00SUBMITTALCOVER SHEETMEP SITE