HomeMy WebLinkAboutC010_General-Notes+Legend+Abbreviations 12-18-2020HY DLEGEND
EXISTING FIRE HYDRANT
EXISTING WATER VALVE
EXISTING SANITARY SEWER MANHOLE
EXISTING STORM DRAIN FACILITIES
EXISTING FIBER/TELEPHONE FACILITIES
EXISTING ELECTRICAL FACILITIES
EXISTING GAS FACILITIES
EXISTING TRAFFIC SIGN
EXISTING WELL
EXISTING CMP CULVERT
EXISTING RCP CULVERT
ESD EXISTING STORM SEWER MAIN
ES EXISTING SAN SEWER MAIN
ESS EXISTING SAN SEWER SERVICE
F EXISTING FIBER OPTIC
EXISTING UNDERGROUND POWEREE
EXISTING UNDERGROUND TELEPHONET
C C EXISTING UNDERGROUND CABLE
G G EXISTING GAS LINE
EXISTING OVERHEAD POWER
OHT OHT EXISTING OVERHEAD TELEPHONE
P P EXISTING PETROLEUM LINE
EW EXISTING WATER MAIN
EWS EXISTING WATER SERVICE
SD SD
RD RD
PROPOSED STORM DRAIN INLET
PROPOSED STORM DRAIN MANHOLE
PROPOSED STORM DRAIN
PROPOSED ROOF DRAIN
PROPOSED SAN SEWER CLEANOUTS
WS WS
UTIL UTIL
PROPOSED DOMESTIC WATER SERVICE
PROPOSED UTILITY CONDUIT
EXISTING BUILDING
EXISTING BUILDING ROOF
EXISTING CONCRETE
EXISTING CURB FACE
EXISTING CURB FLOWLINE
EXISTING TOP BACK OF CURB
EXISTING PARKING STRIPE
EXISTING ASPHALT//////
EXISTING GRAVEL EDGE
EXISTING SIDEWALK
PROPOSED BUILDING
PROPOSED CONCRETE
PROPOSED CURB FLOWLINE
PROPOSED TOP BACK OF CURB
PROPOSED PARKING STRIPE
PROPOSED ASPHALT
PROPOSED GRAVEL EDGE
PROPOSED SIDEWALK
GRAPHICAL SIDEWALK JOINT
PROPOSED ASPHALT GRADE BREAK
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
4654
4653.50
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
4656
4655.50
PERF PERF PROPOSED PERFORATED DRAIN PIPE
IRRIG IRRIG PROPOSED IRRIGATION SLEEVE
PROPOSED GRAVITY SANITARY SERVICESS SVC
FIRE FIRE PROPOSED FIRE SERVICE
SLD SLD PROPOSED SLOTTED DRAIN
8W 8W PROPOSED 8" WATER MAIN
PROPOSED GRAVITY 8" SANITARY MAIN8S8S
PROPOSED PEDESTRIAN CORRIDOR EASEMENT
8W 8W PROPOSED 8" WATER MAIN
PROPOSED BUILDING SETBACK
PROPOSED SPECIAL RESIDENTIAL SETBACK
PROPOSED PEDESTRIAN CORRIDOR SETBACK
PROPOSED PUBLIC UTILITY EASEMENT
PROPOSED PARKING SETBACK
ABDN ABANDON
AC ASPHALTIC CONCRETE, ALUMINUM CAP
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJACENT, ADJUST
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECTURE, ARCHITECTURAL
ARCP ARCHED REINFORCED CONCRETE PIPE
ASPH ASPHALT
AVG AVERAGE
BC BUILDING CORNER
BFF BELOW FINISHED FLOOR
BH BOREHOLE
BLDG BUILDING
BLK BLOCK
BM BENCHMARK
BRG BEARING
BW BOTTOM OF WALL
CHK CHECK
CI CAST IRON
CIPC CAST IN-PLACE CONCRETE
CIRC CIRCULAR
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
CO CLEANOUT
COB CITY OF BOZEMAN
COMB COMBINATION
CONC CONCRETE
CONN CONNECT, CONNECTION
COORD COORDINATE
CP CONTROL POINT
CPP CORRUGATED PLASTIC PIPE
CSP CORRUGATED STEEL PIPE
CTR CENTER
CU CUBIC
CU FT, CF CUBIC FEET
CU IN CUBIC INCH
CULV CULVERT
CU YD CUBIC YARD
D & L D&L FOUNDRY AND SUPPLY
DBL DOUBLE
DI DUCTILE IRON, DRAIN INLET
DIA, Ø DIAMETER
DIM DIMENSION
DIR DIRECTION
DTL DETAIL
DWG DRAWING
E EAST
EA EACH, EDGE OF ASPHALT
EC EDGE OF CONCRETE
EG EDGE OF GRAVEL, EXISTING GROUND
EJIW EAST JORDAN IRON WORKS
EL, ELEV ELEVATION
ELEC ELECTRIC, ELECTRICAL
ENGR ENGINEER
EP EDGE OF PAVEMENT
EXC EXCAVATE
EX EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FES FLARED END SECTION
FET FLARED END TERMINAL
FF FINISHED FLOOR
FG FINISHED GRADE
FHYD FIRE HYDRANT
FL FLOWLINE
FLR FLOOR
FT FOOT, FEET
FTG FOOTING
GA GAGE, GAUGE
GAL GALLON
GB GRADE BREAK
GFA GROSS FLOOR AREA
GND GROUND
GSP GALVANIZED STEEL PIPE
GVL GRAVEL
HC HANDICAP
HDPE HIGH DENSITY POLYETHYLENE
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
HWY HIGHWAY
HYD HYDRANT
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN INCH
INSUL INSULATE
INT INTERIOR
INV INVERT
LAT LATITUDE
LF LINEAR FEET
LONG LONGITUDE, LONGITUDINAL
LT LEFT
LVL LEVEL
MATL MATERIAL
MAX MAXIMUM
MDT MONTANA DEPARTMENT OF
TRANSPORTATION
MECH MECHANICAL
MFD MANUFACTURED
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
N NORTH
NE NORTHEAST
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
NW NORTHWEST
OC ON CENTER
OD OUTSIDE DIAMETER
OHP OVERHEAD POWER
PC POINT OF CURVE
PI POINT OF INTERSECTION
PL PROPERTY LINE
PRELIM PRELIMINARY
PROP PROPERTY
PT POINT, POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
RACET ROAD APPROACH CULVERT END
TERMINAL
R, RAD RADIUS
RC REINFORCED CONCRETE
RCP REINFORCED CONCRETE PIPE
RD ROAD, ROOF DRAIN
REF REFERENCE
REQD REQUIRED
RT RIGHT
R/W RIGHT-OF-WAY
S SOUTH
SAN SANITARY
SCH SCHEDULE
SD STORM DRAIN
SE SOUTHEAST
SEC SECTION
SPEC SPECIFICATION
SQ SQUARE
SQ FT, SF SQUARE FOOT
SQ IN SQUARE INCH
STA STATION
SS SANITARY SEWER
STD STANDARD
SVC SERVICE
SW SIDEWALK, SOUTHWEST
TB THRUST BLOCK
TBC TOP BACK OF CURB
TEMP TEMPORARY, TEMPERATURE
TOC TOP OF CONCRETE
TRANS TRANSITION
TW TOP OF WALL
TYP TYPICAL
UG UNDERGROUND
UTIL UTILITY
VERT VERTICAL
VOL VOLUME
VPD VEHICLES PER DAY
W WEST
W/WITH
W/O WITHOUT
WL WATERLINE
TR WATER
WSEL WATER SURFACE ELEVATION
WV WATER VALVE
XFMR TRANSFORMER
YD YARD
NOTE:
FOR ABBREVIATIONS NOT LISTED, CONTACT THE
ENGINEER.
GENERAL NOTES:
1.STANDARD SYMBOLS AND LINE TYPES ARE SHOWN IN THE LEGEND. SOME SYMBOLS OR LINE TYPES SHOWN MAY NOT BE SHOWN ON THE PLANS.
2.IN GENERAL, EXISTING STRUCTURES AND FACILITIES ARE NOTED AS "EXISTING" AND ARE SHOWN IN LIGHT LINE WEIGHTS OR AS SCREENED BACKGROUND. NEW STRUCTURES OR FACILITIES
ARE SHOWN IN HEAVY LINE WEIGHTS.
CONSTRUCTION NOTES:
1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, SIXTH EDITION DATED APRIL 2010 (MPWSS);
THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECT SPECIFICATIONS.
2.CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE DIVISION OF INDUSTRIAL REGULATIONS (OSHA) SAFETY STANDARDS. IF REQUESTED BY THE INSPECTOR, THE CONTRACTOR SHALL
PROVIDE PROOF OF A PERMIT FROM SAID DIVISION.
3.THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED WITHIN THE PROJECT LIMITS. MATERIALS AND EQUIPMENT SHALL BE STORED ON THE PROJECT SITE WHERE APPROVED BY THE
OWNER. IT SHALL BE UNDERSTOOD THAT THE RESPONSIBILITY FOR PROTECTION AND SAFEKEEPING OF EQUIPMENT AND MATERIALS ON OR NEAR THE SITE WILL BE ENTIRELY THAT OF THE
CONTRACTOR AND THAT NO CLAIM SHALL BE MADE AGAINST THE OWNER BY REASON OF ANY ACT OF AN EMPLOYEE OR TRESPASSER.
4.CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND ARE TO BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO
COMMENCEMENT OR CONTINUATION OF CONSTRUCTION ACTIVITIES.
5.REFERENCE ALL SURVEY MONUMENTS, SECTION CORNERS, 1/4 CORNERS, AND PROPERTY CORNERS PRIOR TO BEING DISTURBED BY CONSTRUCTION. ANY MONUMENTS AND CORNERS
DISTURBED DURING CONSTRUCTION SHALL BE REPLACED BY A PROFESSIONAL LAND SURVEYOR (PLS) REGISTERED IN THE STATE OF MONTANA.
6.A PRE-CONSTRUCTION MEETING (AS REQUIRED) SHALL BE HELD WITH THE GENERAL CONTRACTOR, SITE SUBCONTRACTOR,CITY OF BOZEMAN, OWNER, AND MORRISON-MAIERLE, INC. PRIOR
TO THE START OF CONSTRUCTION.
7.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE CITY, COUNTY, AND/OR STATE INSPECTOR 48 HOURS PRIOR TO COMMENCING CONSTRUCTION AND 24 HOURS IN ADVANCE OF
SPECIFIC INSPECTION NEEDS DURING THE COURSE OF THE WORK. ALL WORK SHALL BE PERFORMED DURING NORMAL WORKING HOURS AND SUBJECT TO THE AVAILABILITY OF AN
INSPECTOR AND APPROVED BY THE ENGINEER. THE CONTRACTOR WILL BE BILLED FOR SAID INSPECTION SERVICES AS PROVIDED IN THE MOST RECENTLY ADOPTED FEES FOR SUCH
SERVICES.
8.THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION ACTIVITIES IN A MANNER TO MINIMIZE INCONVENIENCE TO THE ADJACENT BUSINESSES.
9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL PUBLIC AND PRIVATE PROPERTY INSOFAR AS IT MAY BE AFFECTED BY THESE OPERATIONS, ALL COSTS FOR PROTECTING,
REMOVING, AND RESTORING EXISTING IMPROVEMENTS SHALL BE BORNE SOLELY BY THE CONTRACTOR.
10.THE CONTRACTOR SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN
ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS.
11.THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ON EXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS-OF-WAY AND
MAKE SURE STREETS AND WALKWAYS ARE CLEANED AT THE END OF EACH WORKING DAY.
12.CONSTRUCTION WORK ZONE TRAFFIC SIGNS SHALL BE FURNISHED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE REGULATORY AGENCIES
HAVING JURISDICTION. A TRAFFIC CONTROL PLAN, PREPARED BY THE CONTRACTOR, MAY BE REQUIRED BY THE CITY OR STATE. "CONSTRUCTION AHEAD" WARNING SIGNS ARE TO TO BE
INSTALLED ALONG ADJACENT ROADS OR DRIVEWAYS. FLASHERS WITH CAUTION TAPE ARE TO BE INSTALLED WHERE ANY CONSTRUCTION ACTIVITY CROSSES A SIDEWALK OR PEDESTRIAN
PATH IN ACCORDANCE WITH THE SPECIFICATIONS AND ANY OR ALL LOCAL REGULATIONS.
13.AREAS ON THE SITE TO BE GRADED SHALL BE CLEARED AND GRUBBED OF ALL VEGETATION AND DEBRIS. THESE MATERIALS SHALL BE REMOVED FROM THE SITE BY THE CONTRACTOR.
14.SURFACE SOILS WITHIN THE PROJECT LIMITS CONTAINING ROOTS AND ORGANIC MATTER SHALL BE STRIPPED DOWN AND STOCKPILED OR DISCARDED AS DIRECTED BY THE OWNER OR
ENGINEER. SOIL TEST PIT INFORMATION IS PROVIDED IN THE GEOTECHNICAL INVESTIGATION BY RAWHIDE ENGINEERING, INC. DATED AUGUST 2016. DEEPER STRIPPING WHERE REQUIRED
TO REMOVE WEAK SOILS OR ACCUMULATIONS OR ORGANIC MATTER, SHALL BE PERFORMED WHEN DETERMINED BY THE ENGINEER OR OWNER'S AUTHORIZED REPRESENTATIVE. STRIPPING
SHALL BE REMOVED FROM THE SITE OR STOCKPILED AT A LOCATION DESIGNATED BY THE OWNER.
15.THE GROUND SURFACE EXPOSED BY STRIPPING SHALL BE SCARIFIED TO A MINIMUM DEPTH OF EIGHT INCHES (8"), MOISTURE CONDITIONED TO THE PROPER MOISTURE CONTENT FOR
COMPACTION, AND COMPACTED AS REQUIRED FOR COMPACTED FILL. RECOMPACTION SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACING FILL.
16.NO STOPPING, PARKING, OR STORING OF CONSTRUCTION MATERIALS IN THE PUBLIC STREETS /ROADS, RIGHTS-OF-WAY, OR ANY DRIVEWAY IS ALLOWED.
17.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR
ENGINEER.
18.ASPHALT AND CONCRETE SHALL BE SAW CUT OR NEAT CUT AS APPROVED BY THE ENGINEER.
19.THE CONTRACTOR SHALL UTILIZE COMPACTION EQUIPMENT SUITABLE FOR THE SOIL TYPES AND SURFACE MATERIALS ENCOUNTERED ON THE PROJECT.
20.SUBGRADE, SUB-BASE, BASE, AND SURFACE COURSE COMPACTION SHALL CONFORM TO ALL APPLICABLE SPECIFICATIONS NOTED IN THE MPWSS; CITY OF BOZEMAN MODIFICATIONS TO THE
MPWSS; AND/OR THE GEOTECHNICAL INVESTIGATION BY RAWHIDE ENGINEERING INC. DATED MAY 4, 2018.
21.CONCRETE SHALL BE CLASS M-4000 UNLESS OTHERWISE SPECIFIED.
22.CONTRACTION JOINTS SHALL BE CONSTRUCTED BY SAWING OR SCORING. WHEN SCORING, A TOOL SHALL BE USED THAT WILL LEAVE CORNERS ROUNDED AND TO DESTROY AGGREGATE
INTERLOCK FOR SPECIFIED MINIMUM DEPTH.
23.GRADE ELEVATIONS INDICATED BY "XX.XX" ON PLANS ARE +4700' TO PROJECT DATUM.
24.SIDE SLOPES FROM DRIVE AND PARKING AREAS SHALL BE 4:1 MAX UNLESS OTHERWISE SPECIFIED.
25.CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THERE IS A CONSTRUCTION PERMIT APPROVED BY THE MONTANA DEPARTMENT OF ENVIRONMENTAL QUALITY (MDEQ) OR LOCAL
GOVERNING AGENCY AS APPROPRIATE FOR THE CONTROL OF STORM WATER RUNOFF. IF THERE IS NOT AN APPROVED PERMIT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING
THE NECESSARY APPROVALS FROM MDEQ OR THE LOCAL GOVERNING AGENCY.
26.CONTRACTOR IS RESPONSIBLE FOR PROJECT DUST CONTROL.
27.ACCESSIBLE ROUTES SHALL HAVE A MAXIMUM. RUNNING SLOPE OF 5%.
GENERAL UTILITY NOTES:
1.THE LOCATION, DEPTH, AND SIZE OF EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTENCE,
LOCATION, DEPTH, SIZE, LINE, AND GRADE OF EXISTING UTILITY CONNECTIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR PROVIDE PROPER PROTECTION WHEN LOCATION IS KNOWN.
2.LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY GENERAL CONTRACTOR AND THE UTILITY COMPANY PROVIDING SERVICE. ANY PROPOSED
ADJUSTMENTS TO DRY UTILITY LOCATION SHALL BE COORDINATED WITH UTILITY COMPANIES.
3.PRIOR TO SUBMITTING PIPING DRAWINGS FOR ANY NEW PIPE THAT IS TO CONNECT TO AN EXISTING PIPE OR STRUCTURE, THE CONTRACTOR SHALL EXPOSE
THE EXISTING PIPE OR STRUCTURE TO VERIFY ITS EXACT LOCATION, SIZE, MATERIALS, INVERT ELEVATIONS, AND GRADE.
4.THE CONTRACTOR SHALL NOTIFY THE MONTANA ONE CALL CENTER @ 811 OR (800) 551-8344 FOR ON-SITE UTILITY LOCATION. ALL KNOWN EXISTING
UTILITIES SHALL BE MARKED BEFORE DIGGING.
5.SITE TO BE ROUGH GRADED PRIOR TO INSTALLATION OF UTILITIES TO ASSURE 6.5 FEET (78 INCHES) OF MINIMUM COVER ON BURIED WATER PIPING OR
DEEPER AS SPECIFIED. IF 6.5 FEET OF MINIMUM COVER CANNOT BE OBTAINED, INSULATION OF BURIED WATER PIPING MAY BE REQUIRED.
6.GENERAL CONTRACTOR SHALL HAVE APPROVAL OF ALL GOVERNING AGENCIES HAVING JURISDICTION OVER ANY UTILITY SYSTEM PRIOR TO INSTALLATION.
7.CONTRACTOR TO COORDINATE WITH CITY ENGINEER PRIOR TO CONNECTING TO EXISTING WATER LINES OWNED AND MAINTAINED BY THE CITY OF
BOZEMAN.
8.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATED BY CITY OF BOZEMAN PUBLIC WORKS DEPARTMENT
PERSONNEL ONLY.
9.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER.
10.GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL TAP AND TIE-IN FEES REQUIRED, AS WELL AS THE COST OF UNDERGROUND SERVICE CONNECTIONS
TO THE BUILDING.
11.ALL GRAVITY SANITARY SEWER PIPING SHALL BE SDR 35 PVC IN ACCORDANCE WITH ASTM D 3034, UNLESS OTHERWISE NOTED.
12.FIRE SERVICE PIPE MATERIAL SHALL BE CLASS 51 DUCTILE IRON MEETING AWWA C151.
13.DOMESTIC WATER SERVICE PIPE MATERIAL SHALL BE CLASS 51 DUCTILE IRON MEETING AWWA C151, UNLESS OTHERWISE NOTED.
14.DIMENSIONS SHOWN ARE TO CENTERLINE OF PIPE OR FITTING.
15.THE PIPE GRADES SHOWN ARE CALCULATED FROM ACTUAL DISTANCES, EDGE-OF-MANHOLE TO EDGE-OF-MANHOLE FOR BOTH SANITARY SEWER AND
STORM DRAIN AS APPLICABLE. THE DISPLAYED PIPE LINEAL FEET REFLECTS THE DISTANCE FROM CENTER-OF-MANHOLE TO CENTER-OF-MANHOLE ON ALL
GRAVITY PIPING.
16.LAY PIPE TO UNIFORM GRADE BETWEEN INDICATED ELEVATION POINTS.
17.SIZE OF FITTINGS SHOWN ON DRAWINGS SHALL CORRESPOND TO ADJACENT STRAIGHT RUN OF PIPE, UNLESS OTHERWISE INDICATED. TYPE OF JOINT AND
FITTING MATERIAL SHALL BE THE SAME AS SHOWN FOR ADJACENT STRAIGHT RUN OF PIPE.
18.THRUST BLOCKS ARE NOT GENERALLY SHOWN ON THE DRAWINGS. ALL FITTINGS, INCLUDING BENDS EQUAL TO OR GREATER THAN TWENTY-TWO AND
ONE-HALF DEGREES (22.5°), TEES, AND PLUGS, SHALL BE THRUST BLOCKED IN CONFORMANCE WITH MPWSS, CITY OF BOZEMAN MODIFICATIONS TO THE
MPWSS, OR MUST HAVE MECHANICALLY RESTRAINED JOINTS WHERE INDICATED ON THE PLANS.
19.ALL VALVES SHALL BE INSTALLED WITH THRUST BLOCKING AND VALVE BOXES IN ACCORDANCE WITH MPWSS AND CITY OF BOZEMAN STANDARDS.
20.VALVE BOXES ARE REQUIRED FOR ALL VALVES IN A BURIED SERVICE.
22.REFER TO BUILDING PLAN FOR LOCATION OF SEWER, DOMESTIC, FIRE, ROOF DRAIN (AS APPLICABLE), AND IRRIGATION CONNECTIONS.
23.GENERAL CONTRACTOR SHALL TRENCH FOR DRY UTILITIES (NATURAL GAS, POWER, CABLE, PHONE, ETC.). DRY UTILITIES ARE TO BE INSTALLED AS NOTED IN
AGREEMENT(S) WITH THE UTILITY COMPANY OR COMPANIES.
24.THE CONTRACTOR SHALL ADJUST ALL NEW AND EXISTING VALVE BOXES, CURB BOXES, AND MANHOLES TO FINAL GRADE UPON COMPLETION OF ALL
CONSTRUCTION. ANY BOXES OR MANHOLES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR OR ANY SUBCONTRACTOR SHALL BE REPAIRED AT
THE EXPENSE OF THE CONTRACTOR. THIS WORK SHALL BE INCIDENTAL TO THE PROJECT. SEPARATE PAYMENT WILL NOT BE MADE.
DETAIL AND SECTION DESIGNATION
A
-X-X
SECTION (LETTER) OR
DETAIL (NUMERAL)
DESIGNATION
DRAWING NUMBER
(OR SAME DRAWING)
ON DRAWING WHERE SECTION
OR DETAIL IS TAKEN:
DRAWING NUMBER
WHERE SHOWN
ON DRAWING WHERE SECTION
OR DETAIL IS SHOWN:
DRAWING NUMBER(S)
WHERE TAKEN
Know what's below.
before you dig.Call
R
ENTITY
POWER & GAS
PROJECT CONTACT LIST
FIRM OR AGENCY ADDRESS CONTACT PHONE & EMAIL
NORTHWESTERN ENERGY 121 EAST GRIFFIN
BOZEMAN, MT 59715 CAMMY DOOLEY (406) 539-2359
Cammy.Dooley@northwestern.com
TELEPHONE CENTURYLINK 2707 WEST MAIN STREET
BOZEMAN, MT 59718 LANCE HOLJE (406) 585-2353
william.holje@centurylink.com
BROADBAND CABLE CHARTER
COMMUNICATIONS
511 WEST MENDENHALL STREET
BOZEMAN, MT 59715 ANDY MOLENDA (406) 586-1837
amolenda@cablevision.com
BROADBAND
FIBER OPTIC MONTANA OPTICOM 144 QUAIL RUN ROAD
BOZEMAN, MT 59718 TRENT FROST (406) 579-5224
tfrost@mt-opticom.com
CITY
ENGINEERING
CITY OF BOZEMAN
ENGINEERING DIVISION
20 EAST OLIVE STREET
BOZEMAN, MT 59715 LANCE LEHIGH (406) 582-2284
llehigh@bozeman.net
CITY PLANNING
& ZONING
CITY OF BOZEMAN
PLANNING DEPARTMENT BRIAN KRUEGER (406) 582-2259
bkrueger@bozeman.net
WATER &
SANITARY SEWER
CITY OF BOZEMAN
WATER & SEWER DIVISION
121 NORTH ROUSE AVENUE
BOZEMAN, MT 59715
JOHN ALSTON
(SUPERINTENDENT)
(406) 582-3200
jalston@bozeman.net
ENGINEER OF
CONTENT MORRISON-MAIERLE, INC.
2880 TECHNOLOGY BLVD W
PO BOX 1113
BOZEMAN, MT 59771-1113
MATT EKSTROM (406) 587-0721
mekstrom@m-m.net
LANDSCAPE
ARCHITECT TD&H 1800 RIVER DRIVE N.
GREAT FALLS, MT 59401 JANA COOPER (406) 761-3010
jana.cooper@tdhengineering.com
20 EAST OLIVE STREET
BOZEMAN, MT 59715
PROJECT
ARCHITECT BGO ARCHITECTS 4202 BELTWAY DR
ADDISON, TX 75001 MIKE MCCARTHY (214) 520-8878
mmccarthy@bgoarchitects.com REVIEWSUBMITTALDEVELOPMENTAPARTMENT UNITS IN BOZEMAN, MONTANAFARRAN REALTY PARTNERSBOZEMAN EAST MIXED-USE4202 BELTWAY DRIVE ADDISON, TX 75001hedk.com214.520.8878Engineering1800 RIVER DR. NO. • GREAT FALLS, MONTANA 59401406.761.3010 • tdhengineering.comGENERAL NOTES,
LEGEND,
& ABBREVIATIONS