Loading...
HomeMy WebLinkAboutL1.15-LANDSCALE DETAILS_11-13-20 NOTES: PROVIDE 2 AGRI-FORM FlNISH GRADE, LAWN H H H NOTES: TABLETS PER SHRUB. z z z dU PLANT ALL TREES SO ROOT FLARE IS VISIBLE *PLANTING PIT SHALL BE g g g ABOVE THE GROUND. 2X THE DIAMETER OF THE \ LOCALLY AVAILABLE BOULDER, q *PLANTING PIT SHALL BE 2X THE DIAMETER OF ROOT BALL. BURY Y3 OF DIAMETER BELOW ZO O O O THE ROOT BALL. VIT %FINISH THE SURFACEPROVIDE 3 AGRI-FORM TABLETS PER TREE. PRUNE ALL DAMAGED OR DEAD � i'',� - ,I* STAKING IS MANDATORY. SUBMIT A SHOP WOOD IMMEDIATELY PRIOR TO VARIES 1 S'-4' ADRAWING OF STAKING PROCEDURE FOR PLANTING -APPROVAL BY THE OWNER'S REPRESENTATIVE. _DO NOT INSTALL WEED BARRIER AROUND 3" MULCH, PER LANDSCAPE II N N cV 8" STAPLES TO ANCHOR WEEDTREES PLANTEDIN LAWN AREAS, PROVIDE WEED PLANS. PULL MULCH 2" H i2 BARRIER AROUND TREES PLANTED IN SHRUB AWAY FROM TRUNK. - -';` - BARRIER AT 3' O.C.; 12"O.C. >BEDS, CUT TO ALLOW FUTURE GROWTH. WEED BARRIER FABRIC AT SEAMS AS REQUIRED004" HIGH WATER SAUCER _ MULCH, PER LANDSCAPE PLANSO OPLANTING MIX, WATER THOROUGHLY - WEED BARRIER FABRIC,DO NOT CUT LEADER, PRUNE TO SERLEAND REMOVE AIR POCKETS. TYPAR 3201 OR 3301 DAMAGED OR DEAD WOOD GUY TREE PER DIAGRAM PROVIDE 6" MIN. CLEARANCE BETWEEN METAL EDGING, PRO STEEL BY wIMMEDIATELY PRIOR TO PLANTING PREVAILINGo /1 BALL& PIT WALLS. ALL WALLS COL-MET, SIZE 1/8" X 4" X 10' ���2 STRAND 12 GAUGE GAL. WIRE WIND SHALL BE FRACTURED & UNGLAZED COLOR TO BE GREEN, OR /� �& GROMMET NYLON STRAPS. APPROVED EQUAL, � � �U8' STEEL T-POSTS DRIVEN NDISTURBED SOIL OUTSIDE(OF PLANTINGM IT INTO MESHREMOVANDL CONITAINRS (INRE, TWINE, CLUDIG FIBER MANUACTURERSURLAP INSTALL INSPECIFICATIONSBEFORE BACKFILLING, STAKE ABOVE FIRST CONTAINERS) PRIOR TO PLANTING \/\/ -I - BRANCHES OR AS NECESSARY FOR FIRM SUPPORT. -III-III- D -I III I, SET ROOT BALL ON 5 METAL EDGING DETAIL 6 BOULDER PLACEMENT 3" DEPTH MULCH; PER LANDSCAPE PLANS, KEEP 2" UNDISTURBED NATIVE SOIL U) F�CALRUNK; BARK MULCH IN LAWN AREAS; LOCAL SHRUB PLANTING Q� ORIGIN OF CHIPS; HEALTHY TREES ONLY, 3'-0" DIA., 4" WATER SAUCER (OMIT IN LAWN AREAS) 1.50' 1°X 1°CHAMFER,TYP. <Z POURED IN PLACE CONC,WALL FINISH NOTES:. WITH REINFORCEMEM, .4" Z GRADE PROVIDE 6" MIN. CLEARANCE BETWEEN BALL& PIT *PROVIDE 1 AGRI-FORM TABLETS PER SHRUB. ARCHITECTURALLY FINISHED, P. O WALLS. ALL WALLS SHALL BE FRACTURED & *PLANTING PIT SHALL BE 2X THE DIAMETER LENGTH PER PLANS o UNGLAZED OF THE ROOT BALL. FINISH PRUNE ALL DAMAGED OR DEAD S C z REMOVE ALL WIRE, TWINE, BURLAP, MESHWOOD IMMEDIATELY PRIOR TO FINISH GRADE, ¢ G Q AND CONTAINERS FROM ENTIRE ROOT BALLPLANTING SLOPE AWAY FROM P ^ WALL, BOTH SIDES - AND TRUNK. 3" DEPTH MULCH PER PLANS. PULL °el °I" w W -IIII - PLANTING SOIL MIX, WATER TO SETTLE AND REMOVE AIRMULCH 2"AWAY FROM TRUNK. ° N POCKETS - DO NOT COMPACT SOIL WEED BARRIER FABRIC, IN PLANTING BEDS 0 " I- - 1=1=1=ll=1=1 - -I -- -I I- 0] —I - SET ROOT BALL ON UNDISTURBED SUBSOIL SAUCERIII III III III III m e e ° e IIII \/J PLANTI G MI4" HIGH XER WATER THOROUGHLY II III III ill Illllllll1 J II II I- Q DECIDUOUS TREE TO SETTLE AND REMOVE AIR _ 1 POCKETS. PROVIDE 8 MIN. 1 ZLu FINISH*CLEARANCE BETWEEN BALL& PIT 11 III-III II IILII- /� LIJ WALLS. ALL WALLS SHALL BE FRACTURED & UNGLAZED =III=1 1L 111=1 111 1= 11=1i- III Illd _. =11 "' zZ REMOVE ALL WIRE, TWINE, BURLAP BASE COARSE D AGG. z NOTES: MESH AND CONTAINERS (INCLUDING FIBER *PLANT ALL TREES SO ROOT FLARE HAS THE SAME CONTAINERS) PRIOR TO PLANTING 95%COMPACTED Q RELATIONSHIP TO FINISH GRADE AS ORIGINALLY - NOTES: SUBGRADE,TYP. GROWN IN THE NURSERY. SET ROOT BALL ON *� *PLANTING PIT SHALL BE 2X THE DIAMETER OF THE I-III-III-I PRIOR TO BEGINNING THE <rr UNDISTURBED NATIVE SOIL FABRICATION OF THE WALL,THE Q ROOT BALL. pp CONTRACTOR SHALL SUBMIT SHOP n *PROVIDE 3 AGRI-FORM TABLES PER TREE. ORNAMENTAL GRASS & PERENNIAL PLANTING DRAWINGS FOR APPROVAL. Q�f * STAKING IS MANDATORY. SUBMIT A SHOP DRAWING < OF STAKING PROCEDURE FOR APPROVAL BY THE OWNER'S REPRESENTATIVE. DETAIL IS MEANT TO SHOW DESIGN INTENT, FINAL SELECTION OF SITE *DO NOT INSTALL WEED BARRIER AROUND TREES FURNITURE WILL BE DETERMINED AT TIME OF INSTALLATION PLANTED IN LAWN AREAS, PROVIDE WEED BARRIER CONCRETE UNIT PAVERS, 12"x24"VANCOUVER BAY SLAB CIP CONC SEATWALL PLANTER AROUND TREES PLANTED IN SHRUB BEDS, CUT TO EXPANSION JOINT, BY MUTUAL MATERIALS, COLOR ALLOW FUTURE GROWTH. SEE CIVIL TO BE 25% CHARCOAL, TOOLED CONTROL 75% GRAY, FILL JOINTS DO NOT CUT LEADER, LOCATION PER, WITH SAND PRUNE DAMAGED OR DEAD JOINT WOOD IMMEDIATELY PRIOR GUY TREE PER DIAGRAM SHEET L3.01 Z� w TO PLANTING FINISH GRADE 1" SAND BASE PREVAILING,� /1 CONCRETE SIDEWALK, US 10ONW FILTER FABRIC, 3 2 STRAND O GAUGE GAL. WIND ���� WIRE & GROMMET NYLON SEE CIVIL LEVEL OR APPROVED EQUAL STRAPS 8' STEEL T-POSTS DRIVEN (MIN N FIRMLY INTO UNDISTURBED SOIL OUTSIDE OF PLANTING PR ------ � BEFORE BACKFILLING, STAKE ABOVE FIRST �o --. •• - z Lu BRANCHES OR AS NECESSARY FOR FIRM SUPPORT. 6"CRUSHED GRAVEL 4 _ H 3" DEPTH MULCH; PER LANDSCAPE PLANS, SUBBASE LEVELING COURSE, -III III III III III III-III = d LLI KEEP 2" FROM TRUNK; BARK MULCH IN LAWN SEE CIVIL 1 III it III III III AGGREGATE BASE, O LU m AREAS; LOCAL ORIGIN OF CHIPS; HEALTHYIII Ii=III III III III i- COMPACTED TO 95% LLJ TREES ONLY, 3'-0" DIA., TYPICAL i- 1-1 �= 95% COMPACTED SUBGRADE _.40 :> (/D 4" WATER SAUCER (OMIT IN LAWN AREAS) NOTES: ea FINISH PROVIDE 6" MIN. CLEARANCE BETWEEN 1.APPLY'JOINT STABILIZING SEALER' BY SUREBOND#SB-1300-1370 TO CONC. UNIT PAVERS PER MFR'S GRADE _ _/'/"% \\ BALL& PIT WALLS. ALL WALLS SHALL BE RECOMMENDATIONS. FRACTURED & UNGLAZED - EE REMOVE ALL WIRE, TWINE, BURLAP, MESH CONCRETE UNIT PAVERS �� � AND CONTAINERS FROM ENTIRE ROOT BALL w^ -II I AND TRUNK. -I L U PLANTING SOIL MIX, WATER TO SETTLE 4.00' =AND REMOVE AIR POCKETS - DO NOT DURNI ITl1REMW NT BTO SHOW E DETERMINED NEDIGATITMETOF NNSTALL4TON SELECTION OF SITE C COMPACT SOIL IS SET ROOT BALL ON UNDISTURBED SUBSOIL CONIFEROUS TREE u W IIII((IIIIII((II IIII((IIIIIIrrIIIIIIrrI o TREEGRATE o ���0000UU����000UUU�� - - j! < q w �< m w CONCRETE SIDEWALK, - - w PER ARCH. �rr 48-INCH SQUARE, ADA, - "7 x o o TREEGRATE, BY � r o IRONSMITH MODE # 36 - - Q 5 29 19 1.33. L 48 .. .....,, .. . .. _ DATE o o o - o -III III-III- III I- o o CENTER TREE IN TREEGRATE Q PROJECT s 11 111 II-I III -II o o III-III-III -III-III- �0000a00000000aaao �- -- - - = 16206 I_I-III=flh=H 1-III- - I I I o AJDACENT CONCRETE, SEE DETAIL IS MEANT TO SHOW DESIGN INTENT, FINAL SELECTION OF SITE Q SHEET NUMBER -I-III- - SEE DTL 1 L1.D5 FOR 00o0000D000000000000000000000�000000�I= NCH FURNITURE WILL BE DETERMINED AT TIME OF INSTALLATION Q —I1I, 1II - PLANTING INSTRUCTIONS _ EXPANSION JOINT (TYP.) L1 .15 ,� ,� PAVILION SHELTER 3 PARKLAND SEATING SECTION SEE CIVIL CD TREE GRATE LANDSCAPE O PLAN DETAILS 0