HomeMy WebLinkAboutE1.00 - ELECTRICAL SITE PLAN (11X17)_11-13-20ZONE 1WATERCOURSESETBACK, TYP.ZONE 2WATERCOURSESETBACK, TYP.ZONE 1WATERCOURSESETBACK, TYP.ZONE 2WATERCOURSESETBACK, TYP.ZONE 1WATERCOURSESETBACK, TYP.ZONE 2WATERCOURSESETBACK, TYP.ccccTTSCHACHE LANETccccccccccc810117799111111997786111010111199977811569119835688101010289101011101058859cc7465ccc474Tcccc10cccccccccccccccccccPL2PL2PL2PL2PL2PL1PL1PL1PL2PL2PL1PL1PL2PL1PL1PL1PL1PL1PL1PL1PL1PL1'MMCA''MMCC1''MMCC2''MMCC3''MMCD'333333344444442222PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1PL1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1B1'MMCB1''MMCB2'SL25(TYP.)SL25(TYP.)SL25(TYP.)SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL25(TYP.)SL2SL2SL2SL2SL2SL2SL2SL25(TYP.)SL2SL2SL2SL2SL2SL25(TYP.)SL2SL2SL2SL2SL25(TYP.)SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL25(TYP.)5(TYP.)SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL25(TYP.)5(TYP.)5(TYP.)SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL2SL25(TYP.)5(TYP.)5(TYP.)10' Clearence (typical)SL2SL2SL2SL2SL2SL2SL2SL2SL203030303030303SL603REVIEW
SUBMITTAL
DEVELOPMENTDATE05-29-1916206SHEET NUMBERAPARTMENT UNITS IN BOZEMAN, MONTANA
FARRAN REALTY PARTNERSPROJECTBOZEMAN EAST MIXED-USE
4202 BELTWAY DRIVE ADDISON, TX 75001
hedk.com214.520.8878
Engineering
1800 RIVER DR. NO. • GREAT FALLS, MONTANA 59401
406.761.3010 • tdhengineering.com
TD&H PROJECT NO: 16-268
REV DATE
02.14.20
REVISION
CITY COMMENTS01
07.31.20 CITY COMMENTS02
11.13.20 CITY COMMENTS03PLANE1.00ELECTRICAL SITESCALE: 1"=40'-0"ELECTRICAL SITE PLAN118"~2"#4 BARE COPPER BOND FROM BOLT TOREBAR WITH EXOTHERMIC WELD ORCOMPRESSION FITTINGBASE COVER TO MATCH POLE WITH STAINLESSSCREWSSCHEDULE 40PVC (1") TOHANDHOLE OR NEXTFIXTURE AS SHOWN.NUMBER OF FIXTURE HEADSVARY WITH TYPE OF FIXTURESEE FIXTURE SCHEDULECONCEALED WELDED STEEL TENONWITH STAINLESS STEEL BOLTS (ALLWITH POLE)POLE PER SCHEDULENON-SHRINK GROUT UNDER BASEPLATE PACKED TIGHT AFTERLEVELING30" MINCURBLENGTH OF ANCHOR BOLTS PERMANUFACTURERS RECOMMENDATIONS. INSTALLPER FACTORY TEMPLATE. DOUBLE LUGS WITHFLAT WASHERS AT BASE PLATE. CLEAN BOLTTHREADS AND SURFACES TO PROVIDEGROUNDING CONTINUITY TO POLE.#4 REBAR CAGE AT 6"O.C. EACH WAY TOP TO BOTTOM.INSTALL (3)#4 HORIZONTAL TIES WITHIN TOP 6" OF BASE.CONTRACTOR MAY USE PRE-CAST POLEBASE. SUBMIT PRE-CAST DRAWING TOENGINEER FOR APPROVAL.HANDHOLE WITH GROUNDING LUGRUBBED BASE TO 12" BELOW GRADE. RUBCORNERS ROUND AND SIDES SMOOTHLANDSCAPED SURFACE FINALGRADE6'-0" MINIMUM24" ROUND FORMEDSITE LIGHTING POLE BASE DETAILNTSDETAIL GENERAL NOTES:1.INCREASE THE SPECIFIED HEIGHT OF THE POLE BY 2'-0" TO ENSURE UNIFORM FIXTUREMAINTAIN HEIGHT WHERE THE 6" BASE IS USED.2.PROTECTED AREA IMPLIES THE POLE IS INSTALLED AT LEAST 30" FROM PARKING ORDRIVE AREAS.POLE: 20'BASE: 6"NON-SHRINK GROUT: ~2"TOTAL HEIGHT: 20'-8"A.CONTRACTOR SHALL COORDINATE WITH AN UNDERGROUND LOCATING SERVICE PRIORTO COMMENCING WORK. COORDINATE WITH OTHER SITE DISCIPLINES.B.ROUTE CONDUITS IN COMMON TRENCH WHERE POSSIBLE REFER TO TRENCHINGDETAIL. RE:TRENCHING DETAIL.C.SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.D.SITE LIGHTING AND UTILITY EQUIPMENT SHOWN IN APPROXIMATE LOCATION.COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS, PROPERTY LINES, AND UTILITYCOMPANIES PRIOR TO ROUGH-IN.E.PROVIDE PULL-LINE IN ALL EMPTY CONDUITS.GENERAL NOTES:SYMBOL USED FOR NOTE CALLOUT.KEYED NOTES:1.ROUTE CIRCUIT THROUGH LIGHTING CONTROL PANEL. RE:LIGHTING CONTROL PANELDETAIL.2.(1)4" CONDUIT FOR PHONE SERVICE, (1)2" CONDUIT FOR CATV SERVICE AND (1)4"CONDUIT FOR FIBER OPTIC CABLE SERVICE. COORDINATE INSTALLATIONSREQUIREMENTS WITH UTILITIES. STUB CONDUITS 12" ABOVE FLOOR AT 'TTB' AND STUBCONDUITS TO NEAREST TELEPHONE UTILITY PEDESTAL. COORDINATE UTILITYLOCATION PRIOR TO ROUGH-IN. PROVIDE CONDUIT AS REQUIRED. MARK LOCATIONWITH MONUMENT MARKER. PROVIDE PULL-LINE WITH EACH CONDUIT.3.PAD MOUNTED TRANSFORMER AND PAD BY UTILITY.4.UNDERGROUND SECONDARY. RE:ONE-LINE DIAGRAM.5.CANOPY LIGHTING TO BE AN ADD ALTERNATE. COORDINATE WITH ARCHITECT.6.PROVIDE AND INSTALL 1" CONDUIT FROM FIXTURE/JUNCTION BOX ACROSS THESTREET TO THE ADJACENT DEVELOPMENT FOR CONNECTION TO THE STREETLIGHTING CIRCUITS SERVING THE STREET LIGHTS IN THAT DEVELOPMENT.#030303