HomeMy WebLinkAboutA8-14 BUILDING 'A' ROOF PLAN 11-13-20 ROOF LEGEND: REVISIONS
CONDENSER PENETRATION DRAFT STOP W/ACCESS
SEE 3/A7-26
2-HR FIREWALL
BIDS SCUPPER/DOWNSPOUT
® INDICATES HVAC -
CONDENSING UNIT
4'AREA ADJACENT TO
ROOF WALKING MAT FIRE WALL WHERE
FOR CONDENSER ACCESS PENETRATIONS PROHIBITED
GENERAL NOTES:
-DOWNSPOUT LOCATIONS ARE CONCEPTUAL IN NATURE AND MUST BE
COORDINATED BY THE CONTRACTOR ON SITE WITH THE LANDSCAPING, ■ ■ ■
RETAINING WALLS,SIDEWALKS AND INDIVIDUAL BUILDING W
ORIENTATION AND DRAINAGE TO INSURE THAT OUTFLOW FROM
DOWNSPOUTS DOES NOT CROSS WALKING OR DRIVING SURFACES.IT
IS THE INTENT OF THE ARCHITECT THAT GUTTER DOWNSPOUTS v,
TERMINATE IN UNDERGROUND DRAINAGE PIPING AND CARRIED AWAY
FROM THE BUILDING AND OTHER FINISHED SURFACES WHERE POSSIBLE.
-ROOF TRUSS LAYOUT,PROFILES AND DESIGN ARE TO BE PROVIDED BY
THE TRUSS MANUFACTURER BY WAY OF SHOP DRAWINGS,AND ARE TO
BE SIGNED AND SEALED BY A REGISTERED ENGINEER. z
�/
•REFER TO ELEVATIONS FOR HEEL HEIGHTS. I..I_
•ROOF VENT CALCULATIONS HAVE BEEN PROVIDED TO SHOW THE Q UJ
REQUIRED NFVA. 1 1 1 z
-ROOF PENETRATIONS PROHIBITED WITHIN 4'47 EA.SIDE OF 2 HOUR ■ ■
FIRE WALL. X Q
a-
W
(� DO
/ �V _
z J
cn Q
Lu
w z
z zz
2Q
METAL CANOPY METAL CANOPY METAL CANOPY METALCANOPY I- cl�BELOW BELOW BELOW BELOW
36"PARAPET L6"PARAPET ��"-PAR&ET 36"PARAPET 72"PARAPET UJ Q Q
------- 72"PARAPET 56"PARAPET 56"PARAPET LL
16"PARAPET D.S. 16"PARAPET D.S. 6"PARAPET 16"PARAPET 16"PARAPET 16"PARAPET 16"PARAPET 16"PARAPET _____
E.O.S. y 8= _- D.S. y D.S. _
E,O.S, LL H N N LL E.O.S. E.O.S. O
>� y ❑o❑o❑o❑o ❑o❑o❑o❑o❑o❑o❑o mono
0 0 ¢o MM
zwi o F � ❑O❑OO ❑0❑O❑O❑O ❑O ❑❑❑ F o
¢m O T T T ❑O❑O ❑O ❑°❑O T noun o z
a
�=o
w
F
H
� I ❑O UEO
w
° ❑°❑O ❑O ❑O ❑O O O ❑O ❑O F a w w
❑oo ❑o ❑o❑o❑o❑oo ❑0 0 00 ❑0❑000 0 00 0 ❑o❑o 000o ❑o ❑o mLu a a w
o > �
� frm
GO
o O O o o
CV
a D..
F FN 0�� Lj N 0 F ® 00 X N M NNi=<l\ E.O.S. 00
oU
.O.S.
Jill
T. T a
❑O o
> ai no no ❑O❑O❑O ❑O❑O O O ❑O❑00 O m w o
Z ROOF TOP HVAC UNIT o ~
FUTURE LOCATION FOR ETAIL ROOF TOP H AC UNIT ROOF TOP HVAC UNIT ❑O❑O O o
U AT LEVEL 1 REF.M -� FUTURE L TIO FOR RETAIL FUT RE LOCATION FOR AIL "2
w o i 7AT LEVEL 1 P VEL 1 REF.MEP ❑❑ U
❑°❑O
o0 0(o y y y y b- 16"
sile) SF �i s)(e)16"PARAPET ❑EMOO �❑°� 0 ❑o❑o❑o F � 0 ❑UD.S. E.O.S. D.S. S72"PARAPET 16"PARAPET - D.S. PARAPET 72"PARAPET o DATE
T EOS S.
16"PARAPET 16"PARAPET STAIR A3 16"PARAPET 16"PARAPET 02-14-20
6'PARAPET 56"PARAPET
56"PARAPET 36"PARAPET 120 pgRgp� 36 PARAPET s PROJECT
56"PARAPET
'16206
226'-8" o SHEET NUMBER
`u
A8- 14
BUILDING'A'
1 BUILDING 'A' ROOF PLAN
SCALE: 1/16"=1'-O" a ROOF PLAN
V