Loading...
HomeMy WebLinkAboutC040_Sanitary-Sewer+Storm-Drain-Details 2021-03-191/4" BELOW TOP OF NEW PAVEMENT SURFACE 3'-0" (MIN) PAVED AREAS: INSTALL HEAVY DUTY MONUMENT BOX, SIMILAR TO CAIRD ENG. NO. 50608-1 LANDSCAPED AREAS: SEE DETAIL 2 ON THIS SHEET. PAVING & GRAVEL AS REQUIRED SEAL JOINT WITH RAM-NEK 8" x 3' ROUND CONCRETE SLAB SLIP HUB TO THREADED ADAPTER THREADED PLUG FROST EXPANSION SLEEVE CLEANOUT PIPE - 4" Ø PVC 45° BEND NON-SHRINK BACKFILL END OF TRENCH VERIFY PIPE SIZE PER PLAN DIMENSIONS END OF LINE CLEANOUT (IF REQUIRED) USE PLUG SLOPE SHELF AT 1" PER FOOT RADIUS OF MANHOLE SECTION A-A FRAME AND COVER TO BE EITHER D&L A-1172 RING & A-1178 COVER, EJIW 3771 / 3772 SERIES, OR APPROVED EQUAL. (COVERS SHALL BE STAMPED WITH THE WORDS "SANITARY SEWER" OR "STORM SEWER" AS APPROPRIATE AND HAVE TWO 1" PICK HOLES) MANHOLE RING AND COVER SHALL BE ADJUSTED TO GRADE OF PAVEMENT SURFACE AS REQUIRED USING VARIABLE LENGTH SECTIONS AS REQUIRED MANHOLE STEPS AT 16" ON CENTER 24" OR 27" OPENING ADJUSTABLE RINGS 4" MIN TO 12" MAX FLAT SLAB COVER CUTOUTS AS REQUIRED A A CHANNEL = 1/2 DIAMETER OF PIPE SHELF: SLOPE AT 1" PER FOOT TOWARDS CHANNEL SEE CHANNEL DETAIL PRECAST OR POURED-IN-PLACE BASE. POURED-IN-PLACE BASE, MINIMUM CONCRETE THICKNESS BELOW PIPE IS EIGHT INCHES (8"). PRECAST BASE, MINIMUM THICKNESS TO BE SIX INCHES (6"). POURED-IN-PLACE BASE TO EXTEND BEYOND OUTER EDGE OF MANHOLE WALL. NOTES: 1.ALL JOINTS BETWEEN MANHOLE SECTIONS, ADJUSTING RINGS, MANHOLE RING & TOP SECTION, AND AROUND PIPE INTO MANHOLE SHALL BE WATERTIGHT. JOINTING MATERIAL SHALL BE "RAM-NEK" OR APPROVED EQUAL FOR ALL JOINTS EXCEPT BETWEEN PIPE AND MANHOLE WALL. 2.ADJUSTING RINGS AND CASTING SHALL BE CENTERED ON MANHOLE. 3.REMOVE SHIMS AND GROUT ANY GAPS BETWEEN THE CASTING, ADJUSTING RINGS, AND BARREL. REMOVE EXCESS GROUT. 4.GROUT ALL LIFTING HOLES IN BARREL. 5.ALL LATERAL PIPES SHALL BE FINISHED FLUSH WITH INNER BARREL WALL. NOTE: STORM DRAIN MANHOLES SHALL NOT HAVE FORMED CHANNELS AND THE LOWEST PIPE INVERT SHALL BE NINE INCHES (9") HIGHER THAN THE BOTTOM OF THE MANHOLE. FRAME AND COVER TO BE EITHER D&L A-1172 RING A-1178 COVER, EJIW 3771 / 3772 SERIES, OR APPROVED EQUAL (COVERS SHALL BE STAMPED WITH THE WORDS "SANITARY SEWER" AND HAVE TWO ONE-INCH (1") PICK HOLES) NOTE:FURNISH ONE-HALF INCH BY ONE-HALF INCH (1/2" x 1/2") NON-CORROSIVE STEEL ROD STEPS, TWELVE-INCHES (12") IN WIDTH, ENCASED WITH POLYPROPYLENE. ENSURE STEPS WITHSTAND 400 POUND VERTICAL LOADS AND 1,000 POUND PULL-OUT RESISTANCE. STEPS SHALL LINE UP ABOVE THE MANHOLE OUTLET. MANHOLE STEPS ON 16" CENTERS PRECAST REINFORCED CONCRETE MANHOLE RISER AND ECCENTRIC CONE TOP MANUFACTURED IN ACCORDANCE WITH ASTM DESIGNATION C-478 (TYPICAL FOR POURED-IN- PLACE BASES)SLOPE SHELF AT ONE INCH (1") PER FOOT TOWARD CHANNEL. POSITIVE SEAL PSX GASKETS FOR SANITARY SEWER PIPE CONNECTION REQUIRED. STORM DRAINS SHALL BE CONNECTED USING A RUBBER GROUTING RING. PRE-CAST CHANNEL FLOWLINE GROUT INVERT TO SPRINGLINE OF PIPE IF GAP BETWEEN PIPE AND CHANNEL IS GREATER THAN ONE-EIGHTH INCH (1/8") PRE-CAST OR POURED-IN-PLACE BASE NOTE: ·FOR POURED-IN-PLACE BASE, THE MINIMUM CONCRETE THICKNESS BELOW PIPE IS EIGHT INCHES (8"). ·FOR PRE-CAST BASE, THE MINIMUM THICKNESS BELOW PIPE IS SIX INCHES (6"). ·ALL BASES REINFORCED AS SHOWN. #4 BARS @ 1'-0" ON CENTER NOTE:ALL JOINTS BETWEEN MANHOLE SECTIONS, MANHOLE RING & TOP SECTION, AND AROUND SEWER PIPE INTO MANHOLE SHALL BE WATERTIGHT. JOINTING MATERIAL SHALL BE "RAM-NEK" OR APPROVED EQUAL FOR ALL JOINTS EXCEPT BETWEEN SEWER PIPE AND MANHOLE WALL. A A SLOPE SHELF AT 1" PER FOOT RADIUS OF MANHOLE SECTION A-A NOTE: STORM DRAIN MANHOLES SHALL NOT HAVE FORMED CHANNELS AND THE LOWEST PIPE INVERT SHALL BE NINE INCHES (9") HIGHER THAN THE BOTTOM OF THE MANHOLE. 9" 8"(MIN) DEPTH SCARIFIED, MOISTURE CONDITIONED, & RECOMPACTED SUBGRADE NOTES: 1.PRIOR TO PLACEMENT OF THE BASE COURSE, THE EXPOSED SUBGRADE SHALL BE SCARIFIED TO A MINIMUM DEPTH OF EIGHT INCHES (8") BELOW EXISTING GRADE, MOISTURE CONDITIONED, AND RECOMPACTED TO 95% (MINIMUM) OF MAXIMUM DENSITY AS DETERMINED BY ASTM D 698. 2.AGGREGATE SUB-BASE COURSE SHALL CONFORM TO SECTION 02234 OF THE MPWSS AND INCORPORATE A MAXIMUM PARTICLE SIZE OF THREE INCHES (3"). 3.AGGREGATE BASE COURSE SHALL CONFORM TO SECTION 02235 OF THE MPWSS AND INCORPORATE A MAXIMUM PARTICLE SIZE OF ONE AND ONE-HALF INCHES (1-1/2"). 4.AGGREGATE BASE COURSE SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D 698. NATIVE GROUND 3"MINIMUM DEPTH OF 1-1/2" MINUS CRUSHED BASE COURSE MINIMUM DEPTH OF 6" MINUS PITRUN Know what's below. before you dig.Call R NOT TO SCALE SANITARY SEWER & STORM DRAIN CLEANOUT DETAIL NOT TO SCALE STANDARD STRAIGHT MANHOLE DETAIL NOT TO SCALE ECCENTRIC MANHOLE DETAIL 02720-3 02720-4 PVC CLEANOUT 2" 3" MIN.GRADE PVC CLEANOUT WITH THREADED PLUG 10" ROUND VALVE BOX, GREEN, WITH LOCKING LID, CENTERED OVER CLEANOUT GRAVEL BEDDING & BACKFILL 2" 2" FINISHED NOT TO SCALE CLEANOUT BOX - LANDSCAPED AREAS NOT TO SCALE SEWER ALL WEATHER ACCESS REVIEWSUBMITTALDEVELOPMENTAPARTMENT UNITS IN BOZEMAN, MONTANAFARRAN REALTY PARTNERSBOZEMAN EAST MIXED-USE4202 BELTWAY DRIVE ADDISON, TX 75001hedk.com214.520.8878Engineering1800 RIVER DR. NO. • GREAT FALLS, MONTANA 59401406.761.3010 • tdhengineering.comNOT TO SCALE POND 2 OUTLET STRUCTURE WITH NEW ORIFICE PLATE NOT TO SCALE STEEL OUTLET ASSEMBLY 4