Loading...
HomeMy WebLinkAboutSP104 Fourth Level Floor Plan 12-21-20DN DN 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 B B C C E D H J L L F G K 11 11 10 10 A A LINEN/ STORAGE 495 QUEEN/QUEEN CONN. 419 QUEEN/QUEEN CONN. 417 QUEEN/QUEEN 415 QUEEN/QUEEN MOD 413 QUEEN/QUEEN MOD 411 QUEEN/QUEEN 409 QUEEN/QUEEN 407 QUEEN/QUEEN 405 QUEEN/QUEEN 403 QUEEN/QUEEN 401 QUEEN/QUEEN 402 QUEEN/QUEEN 404 QUEEN/QUEEN 406 QUEEN/QUEEN 408 QUEEN/QUEEN 410 QUEEN/QUEEN 412 QUEEN/QUEEN 414 QUEEN/QUEEN 416 KING SUITE ADA TUB 418 KING 422 KING 424 KING 426 KING 428 KING 430 KING 432 KING 434 KING 436 KING 438 KING ACC. 439 QUEEN/QUEEN CONN. 437 QUEEN/QUEEN 435 QUEEN/QUEEN 433 QUEEN/QUEEN 431 QUEEN/QUEEN 429 QUEEN/QUEEN 423 QUEEN/QUEEN INLINE 421 ELEVATOR LOBBY 491 STAIR 2 452 STAIR 1 450 SP202 3 SP202 1 SP202 2 SP202 4 SP301 2 22 22 8' - 2 " 15 ' - 0 " 25 ' - 7 " 6' - 5 1 / 2 " 28 ' - 6 3 / 4 " 12 ' - 3 " 8' - 2 " 15 ' - 0 " 8' - 0 " 4' - 3 " 28 ' - 6 3 / 4 " 6' - 5 1 / 2 " 25 ' - 7 " 278'-10 1/2" 14'-2 1/4" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 27'-10" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 14'-2 1/4" 278'-10 1/2" 14'-2 1/4" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 13'-11" 14'-2 1/4" 96 ' - 0 1 / 4 " 96 ' - 0 1 / 4 " ELECTRICAL/DATA 493 BUILDING SQ. FT. MAIN LEVEL 20,468 SQ. FT. SECOND LEVEL 17,237 SQ. FT. THIRD LEVEL 17,445 SQ. FT. FOURTH LEVEL 17,866 SQ. FT. TOTAL 73,016 SQ. FT. THE GRAPHIC MATERIAL AND DESIGN ON THIS SHEET ARE INSTRUMENTS OF SERVICE AND REMAIN AT ALL TIMES THE PROPERTY OF THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. REPRODUCTION OR REUSE OF THE MATERIAL AND DESIGN CONTAINED HEREIN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. © DR A W N B Y : PR O J E C T # : CH E C K E D B Y : OWNER: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. 2019 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. ALL RIGHTS RESERVED PROJECT: SHEET # DATE DESCRIPTION 12/6/19 CITY DESIGN SUB. 12/21/20 CITY RESPONSE 12 / 2 1 / 2 0 2 0 2 : 0 9 : 5 9 P M C: \ U s e r s \ p j a c o b s e n \ D o c u m e n t s \ C o u r t y a r d B o z e m a n ( v 2 0 ) _p j a c o b s e n @ t r d p . c o m . r v t SP 1 0 4 4T H L E V E L F L O O R PL A N 18 -16 3 . 0 1 Au t h o r Ch e c k e r 21 6 8 B O O T H I L L C O U R T BO Z E M A N , M T 5 9 7 1 5 BO Z E M A N CO U R T Y A R D HO T E L L L C SI T E S U B M I T T A L CO U R T Y A R D H O T E L B Y MA R R I O T T 3/32" = 1'-0" SP104 LEVEL 4 FLOOR PLAN 1 ROOM TYPE MATRIX UNIT TYPE LEVEL 1 LEVEL 2 LEVEL 3 TOTAL KING 5 25 17 58 2 38 QUEEN QUEEN IN LINE SUITE QUEEN QUEEN CONNECTING - - - 1 - 4 3 10 - - - 1ADA KING SUITE TUB ADA QUEEN QUEEN ROLL-IN 2 - - 2 ADA LEVEL 1 LEVEL 2 LEVEL 3 TOTAL MOBILITY FEATURES (ACCESSIBLE) 2 1 2 7 COMMUNICATION FEATURES (HEARING IMPAIRED) 2 4 3 12 QUEEN QUEEN 9 36 36 117 TOTALS LEVEL 4 9 1 3 1 - LEVEL 4 2 3 36 4 11 21 - 1 1 3ADA KING TUB (CONNECTING) 1 -2KING CONNECTING - 2 - - 1 1-2KING SUITE - QUEEN QUEEN IN LINE SUITE ADA TUB - - -1 QUEEN QUEEN IN LINE CONNECTING - 1 - 1- 1 GENERAL NOTES 1. DO NOT SCALE DRAWINGS 2. ALL EXTERIOR DIMENSIONS ARE GRID, FACE OF FOUNDATION WALL (U.N.O.). 3. ALL EXTERIOR FRAMED WALLS ARE LOCATED WITH EXTERIOR FACE OF SHEATHING ALIGNED TO THE EXTERIOR FACE OF CONCRETE AND GRID (U.N.O.). 4. REFER TO ENLARGED UNIT PLANS SHEETS FOR DETAILED NOTES ON FINISHES AND EQUIPMENT. 5. ALL GYP. BOARD WALLS AND CEILINGS ARE TO BE PAINTED (U.N.O.). 6. ALL INTERIOR HOLLOW METAL DOORS AND WINDOW FRAMES SHALL BE PAINTED. 7. ALL DOOR OPENINGS ARE LOCATED WITH THE HINGE SIDE 4" OFF THE CORNER (U.N.O.). 8. FIRE SPRINKLER LOCATIONS ARE NOT INDICATED. 9. ALL INTERIOR DIMENSIONS ARE TO FACE OF STUD FRAMING (U.N.O.) 10. FIRE STOPPING MATERIAL FOR NON-FERROUS PIPE, CONDUIT AND OTHER SYNTHETIC MATERIALS SHALL BE COMPATIBLE WITH EACH OTHER. 11. PENETRATION OF SMOKE BARRIERS AND PARTITIONS SHALL BE PROVIDED WITH AND APPROVED FIRE/SMOKE SYSTEM OF A MINIMUM OF 1 HOUR FIRE RATED MATERIALS WHICH HAVE BEEN TESTED AND APPROVED BY THE AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) E 814. 12. CABINET WIDTH DIMENSIONS ARE FOR BID PURPOSES ONLY AND MUST BE FIELD VERIFIED. 13. MAX. HEIGHT OF OUTLETS ON KITCHEN COUNTERS TO BE 44". OTHER OUTLETS MUST BE A MIN. OF 15" OFF FLOOR TO A MAX. OF 48" UNLESS LOCATED IN ADA ACCESSIBLE ROOMS. 14. PROVIDE GRAB BAR BLOCKING AT ALL ADA UNITS. 15. REFER TO ENLARGED UNIT PLANS FOR DIMENSIONS AND ADDITIONAL DETAILS. 16. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND THE BUILDING IS DRIED IN. 17. PROVIDE FULL HEIGHT CORNER GUARDS AT ALL OUTSIDE CORNERS.