HomeMy WebLinkAbout38_AA-111_LEVEL 3 FLOOR PLAN AND ROOF PLAN -BUILDING A_11.04.2020RE
F
RE
F
RE
F
A1
A4
A3
A2
AB AA AC AD
B3
AA-300
B3
AA-300
A3
AA-300
A3
AA-300
AA -200
B1
AA -201
B3
AA -400
B3
A-191
A3
A-191
A3
A-191
A3
A-191
A3
1-BR TYPE B
31
1-BR TYPE B
32 1-BR TYPE B
33
1-BR TYPE B
34
CORRIDOR
3-C1
RESIDENT
STORAGE
3-S1
STAIR 1
3-ST1
3-ST1
3-S1
DO
W
N
S
P
O
U
T
,
T
Y
P
TYP
D02
TYP
G10
E30 G30
G30
G30 G30
G30 G30 G30
G30
G30
G30
G30
E45
E30
E30
E21 E21
E21
E30
E45
E30
E30
D02
E30
E30
A-540
B5 TYP
A-540
B6
TYP
G10
G-052
B3
DN
D06
D06 D06
G10
D06
G10
C
D
G
H
G
C
D
D D
C
D
G
G
C
D
DD
G30
G10
G10
G10
G10
G10
G10
G10
G30
G10
U0
1
U0
1
U0
1
U0
1
U0
2
U0
2
U0
2
U0
2
GENERAL APARTMENT FLR PLAN NOTES
1. PLAN DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE WALL, CENTERLINE OF
COLUMN, OR CENTERLINE OF ROUGH OPENINGS, UON. CONTACT ARCHITECT FOR
CLARIFICATIONS.
2. DOORS AND CASED OPENINGS INDICATED ADJACENT TO WALL INTERSECTIONS SHALL BE
LOCATED WITH THE EDGE OF FINISH OPENING SIX INCHES FROM THE ADJACENT WALL AT THE
EXTERIOR AND FOUR INCHES FROM THE ADJACENT WALL.
3. TYPICAL EXTERIOR STUD WALL D02, UON
4. TYPICAL EXTERIOR CLADDING G10, UON
5. SEE SHEET A -620 & A -540 FOR WINDOW LEGEND AND DETAILS.
6. SEE SHEET A -610 & A -545 FOR DOOR SCHEDULE AND DETAILS.
7. SEE SHEET A -605 FOR WALL ASSEMBLIES.
8. INSTALL BLOCKING FOR GRAB BARS IN ALL BATHROOM WALLS SURROUNDING WATER CLOSET,
BATHTUB AND SHOWER. REF A -500.
9. HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL BE
CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT OR RAMP RUN -PER IBC 1014.
10. CONTRACTOR SHALL INSTALL FURRING, SHIMS AND ADDITIONAL LAYERS OF GYPSUM BOARD
AS NECESSARY TO ACHIEVE FLUSH FINISH WHERE SURFACES OF ADJACENT WALL OR SHAFT
ASSEMBLIES ARE NOT, BUT ARE INTENDED TO BE, ALIGNED.
A1
A4
A3
A2
AB AA AC AD
B3
AA-300
B3
AA-300
A3
AA-300
A3
AA-300
AA -200
B1
AA -201
B3
4:12 4:12
9:1
2
9:
1
2
9:1
2
9:1
2
9:1
2
9:
1
2
GUTTER, TYP
ROOF AREA A:
1,856 SF
ROOF AREA B:
2,092 SF
DASHED LINE
FACE OF EXTERIOR WALL, TYP
CONTINOUS
RIDGE VENT, TYP
DOWNSPOUT, TYP
2'-
0
"
TYPICAL ROOF
OVERHANG UON
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
D.S. D.S.
D.S.
D.S.
D.S. G-052
B3
9:1
2
9:
1
2
TYP
2'-0"
TYP
26'-0"
GENERAL ROOF PLAN NOTES
1. SEE DETAIL FOR VENT PIPE PENETRATIONS.
2. SEE XX/A -XXX FOR SATELLITE CONDUIT.
3. PLACE FALL PROTECTION ANCHORS AT SPECIFIED INTERVALS PER MFR INSTRUCTIONS, SEE
PROJECT MANUAL SECTION XXXXX.
/B5 A-513
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
COPYRIGHT GGLO. ALL RIGHTS RESERVED.
ORIGINAL SHEET SIZE IS 24"x36"
SHEET NO.
SHEET TITLE
GGLO PROJECT MANAGER:
GGLO PRINCIPAL IN CHARGE:
PROJECT NO.:
OWNER APPROVAL:
MARK DATE DESCRIPTION
ISSUE INFORMATION
REVISIONS
PROJECT:
OWNER:
PROJECT ADDRESS:
PL
O
T
D
A
T
E
/
T
I
M
E
:
A 11.04.2020 FORMAL SITE PLAN SUBMITTAL
1301 First Avenue, Suite 301
Seattle, WA 98101
http://www.gglo.com
11
/
4
/
2
0
2
0
1
0
:
2
9
:
3
3
A
M
CONNIE ST. GEORGE
TOM SHELDON
2019111.01
COTTONWOOD SUBDIVISION
5500 S COTTONWOOD RD
BOZEMAN, MT 59718
AA-111
LEVEL 3 FLOOR PLAN
AND ROOF PLAN -
BUILDING A
THE COTTONWOOD
PROJECT
COTTONWOOD PROJECT LLC
3112 LOS FELIZ BLVD
LOS ANGELES CA 90039
1/8" = 1'-0" A1 LEVEL 3 FLOOR PLAN - BUILDING A 0'4'8'16'
4
7
1
KEY PLAN -PACKAGE A
6
5
3
2
1/8" = 1'-0" A3 ROOF PLAN - BUILDING A
MARK DATE DESCRIPTION