Loading...
HomeMy WebLinkAboutCURTAIN WALL GLAZING INFORMATION 10-07-2020The Reliance™ Curtain Wall zone-glazed system is easy to install and features exceptional water control and outstanding thermal performance. 1" and 1-1/4" typical infill systems are offered with snap-in glazing adaptors to accommodate 1/4" spandrel glazing. In addition, a complete system for 1/4” infill is available. Reliance™ provides two gasket options: EPDM dense gaskets on both the interior and exterior, or EPDM sponge gaskets on the interior to accommodate molded corners. Other installation features include roll-over and roll-under horizontals to simplify typical field stick erection. Reliance™ Curtain Wall is thermally broken utilizing an EPDM push-in isolator, and an FRP pressure plate is available for the 1" and 1-1/4" systems to take thermal performance to the next level. R E L I A N C E T M C U R T A I N W A L L Reliance™ Curtain Wall—outside glazed, high performance pressure equalized curtain wall system by Oldcastle BuildingEnvelope® Features n Tubular stick built system with heavy-duty vertical options in order to meet higher design criteria n Overall system dimensions: 2-1/2” sightlines in the following system depths: – 1/4" infill: 5-1/4" & 6-1/2" – 1" infill: 6”, 7-1/4" & 10-1/8" (add 1/4" to depth for FRP pressure plate option) – 1-1/4" infill: 7-1/2" (add 1/4" to depth for FRP pressure plate option) n Front set, outside glazed configuration n Captured and SSG (structural silicone glazed) vertical mullions n Thermally broken system n Integrated Solar Eclipse™ sunshade and Solar Shelf™ light shelf n Accommodates 1/4", 1" and 1-1/4" typical infills n Available as a veneer system with 1/4" or 1" typical infill n Accommodates glazed in projected and casement vents n Accommodates low profile or flush door frames for entrance doors n Factory-painted Kynar 500®/Hylar 5000® finishes, meeting all provisions of AAMA 2605 n Factory-anodized finishing Granite Park III, Plano, TX Architect: BOKA Powell 5005 LBJ Freeway, Suite 1050 n Dallas, TX 75244 1-866-OLDCASTLE (653-2278) n obe.com R E L I A N C E T M C U R T A I N W A L L n Air Infiltration: <.06 CFM/SQ FT @ 6.24 PSF per ASTM E283 n Static Water: 15 PSF per ASTM E331 n Dynamic Water: 15 PSF per AAMA 501.1 n Deflection Load: 40 PSF per ASTM E330 n Structural Load: 60 PSF per ASTM E330 n Seismic: Three levels of deflection per AAMA 501.4 n STC per ASTM E90: 37 with laminated glass 33 with clear glass n OITC per ASTM E90: 30 with laminated glass 28 with clear glass Performance n Thermal Performance per AAMA 1503 for clear 1" insulating glass: Aluminum pressure plate U-factor = 0.63 Captured / .61 SSG CRF = 66 Captured / 70 SSG FRP pressure plate U-factor = 0.44 Captured CRF = 68 Captured n Thermal Performance per AAMA 1503 for Low-E 1" insulating glass: Aluminum pressure plate U-factor = 0.44 Captured and 0.37 SSG CRF = 68 Captured and 73 SSG FRP pressure plate U-factor = 0.34 Captured CRF = 78 Captured n NFRC Certified and Thermal Performance Characteristics per AAMA 507 Standard Details