HomeMy WebLinkAboutS3.01 - STRUCTURAL - EXISTING CMU WALL ELEVATIONS04 05 INFILL EXISTING OPENING 8'-5" (V) NEW OPENING 16'-0" (V) 3/S3.01 SEE FOR LINTEL 3/S3.01 SEE FOR LINTEL INFILL W/ 6002162 -43 @ 16" OC W/ 1/2" SHTHG. PROVIDE X -GNP @ 6" OC EDGE FASTENING & 12" OC FIELD FASTENING. BLOCK ALL PANEL EDGES PROVIDE HSS6x2x3/16 AT TOP & SIDE OF INFILL WALL W/ 3/4" DIAM EPOXY ANCHOR INTO GROUTED ADJACENT CELLS (ASSUMED 32" OC) PROVIDE 54 -MIL BOTTOM TRACK W/ 5/8" TITEN HD @ 32" OC / 5" EMBED NEW OPENING 16'-0" (V) JAMB TYPE A, SEE 9/S3.01 JAMB TYPE A, SEE 9/S3.01 1 1 1 ABC EXISTING OPENINGS TO REMAIN EXISTING OPENINGS TO BE REMOVED NEW OPENING 5'-0" (V) NEW OPENING 5'-4" (V) NEW OPENING 10'-0" (V) SEE FOR LINTEL 1/S3.01 SEE FOR LINTEL 3/S3.01 SEE FOR LINTEL 1/S3.01 SEE FOR LINTEL 2/S3.01 SEE FOR LINTEL 2/S3.01 NEW OPENING 13'-0" (V) NEW OPENING 10'-0" (V) NEW OPENING 11'-2" (V) JAMB TYPE A, SEE 9/S3.01 JAMB TYPE A, SEE 9/S3.01 JAMB TYPE D, SEE 9/S3.01 JAMB TYPE A, SEE 9/S3.01 JAMB TYPE C, SEE 9/S3.01 JAMB TYPE C, SEE 9/S3.01 1 SEE FOR LINTEL 2/S3.01 2 SEE FOR LINTEL 1/S3.01 JAMB TYPE A, SEE 9/S3.01 NEW OPENING 5'-0" 2 SECTION A-A (E) CMU WALL THICKNESS L6x4x3/8 LINTEL 5/8"Ø ANCHOR W/ EPOXY & SCREEN TUBE NOTE: 1. SAWCUT HEAD HORIZ, OVERSAW 4" EA SIDE 2. INSTALL DESIGNATED STEEL ANGLE 3. SAWCUT VERT SIDES OF OPENING 4. REMOVE CMU WALL SECTION 5. INSTALL JAMB SECTION EA SIDE OF OPENING 6. INSTALL BOLTS A -A SE C T I O N HSS OR CHANNEL JAMB, SEE ELEV & 5'-4" MAX 6" TYP 9/S3.01 SECTION A-A (E) CMU WALL THICKNESS L8x4x7/16 LINTEL 5/8"Ø ANCHOR W/ EPOXY & SCREEN TUBE NOTE: 1. SAWCUT HEAD HORIZ, OVERSAW 4" EA SIDE 2. INSTALL DESIGNATED STEEL ANGLE 3. SAWCUT VERT JAMBS 4. REMOVE CMU WALL SECTION 5. INSTALL JAMB SECTION EA SIDE OF OPENING 6. INSTALL BOLTS A -A SE C T I O N HSS OR CHANNEL JAMB, SEE ELEV & 12'-0" MAX 8" TYP 9/S3.01 6'-0" MAX SECTION A-A (E) CMU WALL THICKNESS L8x4x3/4 LINTEL 5/8"Ø ANCHOR W/ EPOXY & SCREEN TUBE NOTE: 1. SAWCUT HEAD HORIZ, OVERSAW 4" EA SIDE 2. INSTALL DESIGNATED STEEL ANGLE 3. SAWCUT VERT SIDES OF OPENING 4. REMOVE CMU WALL SECTION 5. INSTALL JAMB SECTION EA SIDE OF OPENING 6. INSTALL BOLTS A -A SE C T I O N HSS OR CHANNEL JAMB, SEE ELEV & 16'-0" MAX 8" TYP 9/S3.01 6'-0" MAX B-B SECTION JAMB - TYPE A HSS OR CHANNEL JAMB. PROVIDE 5/8"Ø ANCHOR W/ EPOXY & SCREEN TUBE @ 48" OC AND AT (E) BOND BEAM AT TOP & BOTTOM OF WALL. C8x18.7 CHANNEL 5/8" ⌀ANCHOR W/ EPOXY & SCREEN TUBE @ 48" OC. 6" TYP LINTEL PER ELEV JAMB - TYPE B MC8x22.8 CHANNEL 5/8" ⌀ANCHOR W/ EPOXY & SCREEN TUBE @ 48" OC. JAMB - TYPE C MC10x33.6 CHANNEL 5/8" ⌀ANCHOR W/ EPOXY & SCREEN TUBE @ 48" OC. JAMB - TYPE D MC10x41.1 CHANNEL 5/8" ⌀ANCHOR W/ EPOXY & SCREEN TUBE @ 48" OC. IF (E) CELLS AT SIDES OF OPENING ARE REINFORCED AND GROUTED FULLY VERTICALLY CONTACT DCI FOR ALT DETAIL ©Copyright D'Amato Conversano Inc. All Rights Reserved This document, and the ideas and designs may not be reused, in whole or in part, without written permission from D'Amato Conversano Inc. D'Amato Conversano Inc. disclaims any responsibility for its unauthorized use. www.dci-engineers.com CIVIL / STRUCTURAL ®1060 Fowler Ave, Suite 202 Bozeman, Montana 59718 P: (406) 556-8600 BIM FILE PATH: SHEET NO.: TITLE: copyright 2018 SMA, P.C. REVISIONS: KEYMAP: HELENA 920 Front Street | Suite 101 Helena | MT | 59601 P| 406/442.4933 www.architects-sma.com ARCHITECT SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: CONSULTANT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: PROJECT NUMBER: Plo t D a t e : BOZEMAN 109 East Oak Street | Suite 2E Bozeman | MT | 59715 P| 406/219.2216 www.architects-sma.com LOGO: C:\Users\jlovgren\Desktop\Local Revit\STRUCT_20151-0023_Gibson Guitar_R20 JAL.rvt 12 / 8 / 2 0 2 0 1 1 : 2 5 : 5 0 A M S3.01 1620 10/9/2020 STRUCTURAL -EXISTING CMU WALL ELEVATIONS JGM JAL GIBSON ACOUSTIC 1620 1894 ORVILLE WAY BOZEMAN, MT 59715 PERMIT SET -SHELL PACKAGE SCALE: 3/16" = 1'-0" 11 EXISTING SOUTH CMU WALL ELEVATION SCALE: 3/16" = 1'-0" 5 EXISTING EAST CMU WALL ELEVATION SCALE: 3/4" = 1'-0" 1 (N) OPENING IN (E) CMU WALL - TYPE 1 SCALE: 3/4" = 1'-0" 2 (N) OPENING IN (E) CMU WALL - TYPE 2 SCALE: 3/4" = 1'-0" 3 (N) OPENING IN (E) CMU WALL - TYPE 3 SCALE: 3/4" = 1'-0" 9 STEEL JAMB AT (N) OPENING NO. DATE REVISION DESCRIPTION 1 11.13.20 Addendum 1 2 12.8.20 Revision 2 / AHJ Review 2