HomeMy WebLinkAbout037-Cottonwood_Ida--L6.00-Lighting Diagram-2019.01.25SP1
Submittal
01-17-2019
12
-
2
0
-
2
0
1
8
1” = 20’-0”
LIGHTING
DIAGRAM
L6.00
1” = 20’-0”
LIGHTING DIAGRAM
Type A - Street Lighting
Type B - Catenary Lighting
Type C - Residential Lighting
Type D - Plaza Lighting
General notes
1. Site lighting to conform with BMC division 38.570:
A. Illumination levels (footcandles) to conform to tables 38.570.040-1 Thru 38.570.040-3.
B. Provide minimum 1 footcandle at walking surface along all egress paths
2. Per bmc ordinance 1925, lighting design will implement best dark-sky lighting practices.
3. See Lighting sheets
A
A
A
B
C C
C
C
D