HomeMy WebLinkAboutSHT A2.1 FIRST FLOOR PLAN 3_19_2020TYP
2
TYP
BO
Z
E
M
A
N
,
M
O
N
T
A
N
A
A
N
E
W
S
E
N
I
O
R
H
O
U
S
I
N
G
P
R
O
J
E
C
T
F
O
R
:
TI
M
B
E
R
R
I
D
G
E
A
P
A
R
T
M
E
N
T
S
19.136edinc Job #:
1535 liberty lane
suite 110b
missoula, montana
59808
phone: 406.540.4437
design
inc
THIS SHEET IS INTENDED TO BE PRINTED
IN COLOR TO FULLY UNDERSTAND THE
INFORMATION BEING PRESENTED.
01.08.20SITE PLAN SUBMITTAL:
27
6
9
T
S
C
H
A
C
H
E
L
A
N
E
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
-
-
-
-
-
-
-
-
-
-
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
-
-
-
-
-
-
-
-
-
-
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
March 19, 2020PRINT DATE
A2.1SCALE :1 First Floor Plan
1/8" = 1'-0"GROSS SQUARE FOOTAGE = 13,305 sqft
(not including decks or patios)
1 SCREENING AT ELECTRICAL AND GAS METERS. WOOD POSTS WITH HORIZONTAL WOOD
SLATS, STAIN/SEAL. SEE DETAIL 1/A1.2.
Keyed Notes - This Sheet
2 CONDENSING UNITS WITH CONCRETE PAD AND WOOD SCREENING, SEE DETAIL 2/A1.2.
LOCATE PAD AS REQUIRED TO ENSURE CONDENSING UNIT LOCATIONS DO NOT ENCROACH
ON REQUIRED 3'-0" MINIMUM CLEARANCE IN FRONT OF ALL EGRESS WINDOWS. ENSURE ALL
CONDENSING UNIT CLEARANCES ARE MEET. COORDINATE EXACT LOCATIONS IN FIELD. SEE
MECHANICAL AND CIVIL.
3 CONCRETE SIDEWALK, SEE CIVIL FOR FULL EXTENT.
4 NOT USED
5 NOT USED
General Notes - Building Plans
1.USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED,
CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
2.DIMENSIONS ARE FROM FACE OF STUD AT NEW WALLS. SEE WALL TYPES FOR ADDITIONAL
WALL ASSEMBLY INFORMATION.
3.SET DOOR ROUGH OPENINGS 6" FROM F.O.S., TYP. U.N.O. CENTER CLOSET DOOR ALONG
LENGTH OF CLOSET.
4.SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING & SHEAR WALLS.
5.COORDINATE ALL COLUMN LOCATIONS AND SIZES WITH STRUCTURAL DRAWINGS.
6.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE
RODS, ETC.
7.SEE RCP, ELECTRICAL & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS &
LIGHTING.
8.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS.
9.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR
FLOOR SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS.
10.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE
ADDITIONAL LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH,
UNIFORM FINISHED SURFACE FOR ENTIRE LENGTH OF WALL.
11.SEE CODE SHEET FOR FURTHER REQUIREMENTS.
12.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ OWNER.
13.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP.
14.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER
HEATER ROOMS, ETC). USE ADDITIONAL LAYERS OF GWB AS REQ'D TO NOT INTERRUPT
RATINGS OF WALLS.
15.SEE A5.1 & A5.2 FOR ALL ACCESSIBLE DETAILS & TYPICAL CASEWORK DIMENSIONS FOR THIS
FLOOR.
16.SEE A5.4 FOR BATHROOM AND KITCHEN INTERIOR ELEVATIONS.
17.SEE A7.1 FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS.
18.SEE A7.1 FOR DOOR AND WINDOW DETAILS.
19.ALL DOORS, WINDOWS, PLUMBING, ETC TO REMAIN SHALL BE PROTECTED AS REQUIRED
DURING CONSTRUCTION.
20.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES.
21.PROVIDE P.T. PLATES AT ALL WALLS ADJACENT TO CEMENTIOUS MATERIAL.
22.CONTRACTOR TO VERIFY IN EACH UNIT THAT THE CABINETRY LENGTH IS COORDINATED AND
VERIFIED WITH THE FRIDGE’S REQUIRED CLEAR SPACE PER THE INSTALLATION INSTRUCTIONS.
SEE A0.0a FOR ALTERNATE NOTES
Alternate Note
1.SEE CODE PLANS AND SECTIONS FOR RATED FLOOR, CEILING, AND ROOF ASSEMBLIES.
2.SEE CODE PLANS FOR FDC AND KNOX LOCATIONS.
Code Notes
Legend - Building Plans - This Sheet
SYMBOL DESIGNATION
ROOM NAME
ROOM NUMBER
DOOR TAG - SEE SCHEDULE
(NOTED THIS SHEET)
WINDOW TAG - SEE SCHEDULE
(NOTED THIS SHEET)
INTERIOR WALL TYPES - SEE
A0.2 FOR WALL ASSEMBLY
SECTION CUT
INDICATES ACCESSIBLE SPACEGRID LINE
42" GUARD RAIL
SEE DETAILS ON A8.4
I-A
EGRESS WINDOW, SEE
WINDOW SCHEDULE(E)
TEMPERED GLASS, SEE
WINDOW SCHEDULE(T)
EXTERIOR RATED WALL - SEE
A0.2 FOR WALL ASSEMBLY, SEE
ELEVATIONS FOR SIDING TYPE
E-#
24" DEEP SHELF W/ CLOSET ROD,
SEE SPEC.
WALL LIGHT, SEE ELECTRICAL
FD FLOOR DRAIN, SEE MECHANICAL
HATCH DESIGNATION
DOWN SPOUT, SEE A2.5DS
HOSE BIB, SEE MECHANICALHB
CONCRETE
RAIN CHAIN, SEE A2.5RC
CONSTRUCTION DESIGNATION
6"
DIM. FROM FACE OF
STUD TO INSIDE OF
FINISH FRAME, TYP. AT
ALL DOORS, U.N.O.
CLEAR FLOOR
SPACE
REQUIRED FOR
ACCESSIBILITY
1 HOUR CONSTRUCTION
1 HOUR
CONSTRUCTION,
SEE A0.2
ASSEMBLIES
NEW
CONSTRUCTION
NOT REQUIRE TO
BE RATED
RATED DOOR
& FRAME,
SEE DOOR
SCHEDULE
TYPICAL CONSTRUCTION 0.5 HOUR CONSTRUCTION
0.5 HOUR
CONSTRUCTION,
SEE A0.2
ASSEMBLIES
NEW
CONSTRUCTION
NOT REQUIRE TO
BE RATED
RATED DOOR
& FRAME,
SEE DOOR
SCHEDULE
2 HOUR CONSTRUCTION
2 HOUR
CONSTRUCTION,
SEE A0.2
ASSEMBLIES
NEW
CONSTRUCTION
NOT REQUIRE TO
BE RATED
RATED DOOR
& FRAME,
SEE DOOR
SCHEDULE
1
X
#
#
A#.#
LANDSCAPING,
SEE CIVIL
WOOD DECKING
A B C D E F G H I J
27
L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
K
29 30 31 32 33 34 35 36 37 38 39 40 41 42 43
A
B
C
E
F
G
H
I
J
L
K
18
19
20
21
22
23
24
25
26
22
30 31 32
33 34 35 36 37 38 39 40 41 42 43
AA
BB
CC
EE
FF
GG
AA
BB
CC
EE
FF
GG
69'-0"
6'-0"5'-0"6'-0"8'-0"6'-0"7'-0"5'-0"4'-0"4'-0"12'-0"6'-0"
11
1
'
-
0
"
5'-
0
"
2'
-
0
"
5'-
0
"
10
'
-
0
"
7'-
0
"
4'
-
0
"
8'
-
0
"
4'
-
0
"
13
'
-
0
"
4'
-
0
"
8'
-
0
"
4'
-
0
"
8'
-
0
"
9'-
0
"
8'
-
0
"
12
'
-
0
"
69
'
-
0
"
6'-
0
"
12
'
-
0
"
4'-
0
"
4'-
0
"
5'
-
0
"
7'
-
0
"
6'-
0
"
14
'
-
0
"
5'
-
0
"
6'-
0
"
111'-0"
12'-0"8'-0"9'-0"8'-0"4'-0"8'-0"4'-0"13'-0"4'-0"8'-0"4'-0"7'-0"10'-0"5'-0"2'-0"5'-0"
8'-0
"
9'-
0
"
22
'
-
0
"
9'-
0
"
3
'
-
0
"
1
0
'
-
6
"
1
0
'
-
6
"
3
'
-
0
"
2
7
'
-
0
"
1
3
'
-
0
"
1'
-
0
"
5'
-
6
"
5
'
-
6
"
1'
-
0
"
7'-0
"
1
3
5
°
135°
135°
1
3
5
°
DD
DD
8'-0
"
6'-
0
"
5
A4.1
1
A4.1
2
A4.1
6
A4.1
7
A4.1
8
A4.1
4
A4.1
4
A4.2
2
A4.2
3
A4.1
1
A4.2
9
A4.1
3
A4.2
G
A
S
F
I
R
E
P
L
A
C
E
D
I
R
E
C
T
I
O
N
A
L
S
I
G
N
A
G
E
EL
E
C
T
R
I
C
A
L
ME
T
E
R
S
GAS METERS
ELE
C
F
I
R
E
P
L
A
C
E
W/
T
V
A
B
O
V
E
F
O
B
TRASH
CHUTE
ABOVE
RECESSED SLAB
RECESSED SLAB
RECESSED SLAB
RECESSED SLAB
MA
I
L
F
D
C
S
FD
BBQ
FD
FD
FD
FD
SCREENING
SC
R
E
E
N
I
N
G
UP
UP
UP
ROOM NAME
RM#
ELEVATOR
ELEV1
MACHINE ROOM
ELEVATOR
C1-7
RESTROOM
C1-5
MAINTENANCE
C1-6
WAITING
C1-2
RECEPTION
C1-3
OFFICE
C1-4
STAIRS
STR1
STAIRS
STR2
STAIRS
STR3
CHUTE ROOM
MECH / GARBAGE
C1-9
ROOM
COMMUNITY
C1-8
(TYPE B)
2 BEDROOM
A101
(TYPE B)
1 BEDROOM
A103
(TYPE B)
1 BEDROOM
A102
(TYPE B)
1 BEDROOM
A104
(TYPE A)
2 BEDROOM
A105
(TYPE B)
2 BEDROOM
A110
(TYPE B)
2 BEDROOM
A106
(TYPE B)
1 BEDROOM
A108
(TYPE B)
1 BEDROOM
A107
E
N
T
R
Y
C
1
-
1
(TYPE A)
1 BEDROOM
A109
A
U
T
O
M
A
T
I
C
D
O
O
R
S
C
R
E
E
N
I
N
G
1
℄
℄
3
3
3
3
3
3
RECESSED SLAB
FD
FDFD
FDFD
FDFD
FDFD
FDFD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
1
A2.5
1
A2.6
1
A2.7
1
A2.8
STORAGE
C1-10
1
A2.9
1 SIM
A2.9
4
A2.9
1
A2.10
2
1
S
C
R
E
E
N
I
N
G