Loading...
HomeMy WebLinkAboutSHT A2.1 FIRST FLOOR PLAN 3_19_2020TYP 2 TYP BO Z E M A N , M O N T A N A A N E W S E N I O R H O U S I N G P R O J E C T F O R : TI M B E R R I D G E A P A R T M E N T S 19.136edinc Job #: 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design inc THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. 01.08.20SITE PLAN SUBMITTAL: 27 6 9 T S C H A C H E L A N E NO T F O R C O N S T R U C T I O N - - - - - - - - - - - N O T F O R C O N S T R U C T I O N - - - - - - - - - - - N O T F O R C O N S T R U C T I O N March 19, 2020PRINT DATE A2.1SCALE :1 First Floor Plan 1/8" = 1'-0"GROSS SQUARE FOOTAGE = 13,305 sqft (not including decks or patios) 1 SCREENING AT ELECTRICAL AND GAS METERS. WOOD POSTS WITH HORIZONTAL WOOD SLATS, STAIN/SEAL. SEE DETAIL 1/A1.2. Keyed Notes - This Sheet 2 CONDENSING UNITS WITH CONCRETE PAD AND WOOD SCREENING, SEE DETAIL 2/A1.2. LOCATE PAD AS REQUIRED TO ENSURE CONDENSING UNIT LOCATIONS DO NOT ENCROACH ON REQUIRED 3'-0" MINIMUM CLEARANCE IN FRONT OF ALL EGRESS WINDOWS. ENSURE ALL CONDENSING UNIT CLEARANCES ARE MEET. COORDINATE EXACT LOCATIONS IN FIELD. SEE MECHANICAL AND CIVIL. 3 CONCRETE SIDEWALK, SEE CIVIL FOR FULL EXTENT. 4 NOT USED 5 NOT USED General Notes - Building Plans 1.USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 2.DIMENSIONS ARE FROM FACE OF STUD AT NEW WALLS. SEE WALL TYPES FOR ADDITIONAL WALL ASSEMBLY INFORMATION. 3.SET DOOR ROUGH OPENINGS 6" FROM F.O.S., TYP. U.N.O. CENTER CLOSET DOOR ALONG LENGTH OF CLOSET. 4.SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF BEARING & SHEAR WALLS. 5.COORDINATE ALL COLUMN LOCATIONS AND SIZES WITH STRUCTURAL DRAWINGS. 6.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE RODS, ETC. 7.SEE RCP, ELECTRICAL & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS & LIGHTING. 8.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS. 9.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR FLOOR SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS. 10.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE ADDITIONAL LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH, UNIFORM FINISHED SURFACE FOR ENTIRE LENGTH OF WALL. 11.SEE CODE SHEET FOR FURTHER REQUIREMENTS. 12.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ OWNER. 13.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP. 14.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER HEATER ROOMS, ETC). USE ADDITIONAL LAYERS OF GWB AS REQ'D TO NOT INTERRUPT RATINGS OF WALLS. 15.SEE A5.1 & A5.2 FOR ALL ACCESSIBLE DETAILS & TYPICAL CASEWORK DIMENSIONS FOR THIS FLOOR. 16.SEE A5.4 FOR BATHROOM AND KITCHEN INTERIOR ELEVATIONS. 17.SEE A7.1 FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS. 18.SEE A7.1 FOR DOOR AND WINDOW DETAILS. 19.ALL DOORS, WINDOWS, PLUMBING, ETC TO REMAIN SHALL BE PROTECTED AS REQUIRED DURING CONSTRUCTION. 20.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES. 21.PROVIDE P.T. PLATES AT ALL WALLS ADJACENT TO CEMENTIOUS MATERIAL. 22.CONTRACTOR TO VERIFY IN EACH UNIT THAT THE CABINETRY LENGTH IS COORDINATED AND VERIFIED WITH THE FRIDGE’S REQUIRED CLEAR SPACE PER THE INSTALLATION INSTRUCTIONS. SEE A0.0a FOR ALTERNATE NOTES Alternate Note 1.SEE CODE PLANS AND SECTIONS FOR RATED FLOOR, CEILING, AND ROOF ASSEMBLIES. 2.SEE CODE PLANS FOR FDC AND KNOX LOCATIONS. Code Notes Legend - Building Plans - This Sheet SYMBOL DESIGNATION ROOM NAME ROOM NUMBER DOOR TAG - SEE SCHEDULE (NOTED THIS SHEET) WINDOW TAG - SEE SCHEDULE (NOTED THIS SHEET) INTERIOR WALL TYPES - SEE A0.2 FOR WALL ASSEMBLY SECTION CUT INDICATES ACCESSIBLE SPACEGRID LINE 42" GUARD RAIL SEE DETAILS ON A8.4 I-A EGRESS WINDOW, SEE WINDOW SCHEDULE(E) TEMPERED GLASS, SEE WINDOW SCHEDULE(T) EXTERIOR RATED WALL - SEE A0.2 FOR WALL ASSEMBLY, SEE ELEVATIONS FOR SIDING TYPE E-# 24" DEEP SHELF W/ CLOSET ROD, SEE SPEC. WALL LIGHT, SEE ELECTRICAL FD FLOOR DRAIN, SEE MECHANICAL HATCH DESIGNATION DOWN SPOUT, SEE A2.5DS HOSE BIB, SEE MECHANICALHB CONCRETE RAIN CHAIN, SEE A2.5RC CONSTRUCTION DESIGNATION 6" DIM. FROM FACE OF STUD TO INSIDE OF FINISH FRAME, TYP. AT ALL DOORS, U.N.O. CLEAR FLOOR SPACE REQUIRED FOR ACCESSIBILITY 1 HOUR CONSTRUCTION 1 HOUR CONSTRUCTION, SEE A0.2 ASSEMBLIES NEW CONSTRUCTION NOT REQUIRE TO BE RATED RATED DOOR & FRAME, SEE DOOR SCHEDULE TYPICAL CONSTRUCTION 0.5 HOUR CONSTRUCTION 0.5 HOUR CONSTRUCTION, SEE A0.2 ASSEMBLIES NEW CONSTRUCTION NOT REQUIRE TO BE RATED RATED DOOR & FRAME, SEE DOOR SCHEDULE 2 HOUR CONSTRUCTION 2 HOUR CONSTRUCTION, SEE A0.2 ASSEMBLIES NEW CONSTRUCTION NOT REQUIRE TO BE RATED RATED DOOR & FRAME, SEE DOOR SCHEDULE 1 X # # A#.# LANDSCAPING, SEE CIVIL WOOD DECKING A B C D E F G H I J 27 L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 K 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 A B C E F G H I J L K 18 19 20 21 22 23 24 25 26 22 30 31 32 33 34 35 36 37 38 39 40 41 42 43 AA BB CC EE FF GG AA BB CC EE FF GG 69'-0" 6'-0"5'-0"6'-0"8'-0"6'-0"7'-0"5'-0"4'-0"4'-0"12'-0"6'-0" 11 1 ' - 0 " 5'- 0 " 2' - 0 " 5'- 0 " 10 ' - 0 " 7'- 0 " 4' - 0 " 8' - 0 " 4' - 0 " 13 ' - 0 " 4' - 0 " 8' - 0 " 4' - 0 " 8' - 0 " 9'- 0 " 8' - 0 " 12 ' - 0 " 69 ' - 0 " 6'- 0 " 12 ' - 0 " 4'- 0 " 4'- 0 " 5' - 0 " 7' - 0 " 6'- 0 " 14 ' - 0 " 5' - 0 " 6'- 0 " 111'-0" 12'-0"8'-0"9'-0"8'-0"4'-0"8'-0"4'-0"13'-0"4'-0"8'-0"4'-0"7'-0"10'-0"5'-0"2'-0"5'-0" 8'-0 " 9'- 0 " 22 ' - 0 " 9'- 0 " 3 ' - 0 " 1 0 ' - 6 " 1 0 ' - 6 " 3 ' - 0 " 2 7 ' - 0 " 1 3 ' - 0 " 1' - 0 " 5' - 6 " 5 ' - 6 " 1' - 0 " 7'-0 " 1 3 5 ° 135° 135° 1 3 5 ° DD DD 8'-0 " 6'- 0 " 5 A4.1 1 A4.1 2 A4.1 6 A4.1 7 A4.1 8 A4.1 4 A4.1 4 A4.2 2 A4.2 3 A4.1 1 A4.2 9 A4.1 3 A4.2 G A S F I R E P L A C E D I R E C T I O N A L S I G N A G E EL E C T R I C A L ME T E R S GAS METERS ELE C F I R E P L A C E W/ T V A B O V E F O B TRASH CHUTE ABOVE RECESSED SLAB RECESSED SLAB RECESSED SLAB RECESSED SLAB MA I L F D C S FD BBQ FD FD FD FD SCREENING SC R E E N I N G UP UP UP ROOM NAME RM# ELEVATOR ELEV1 MACHINE ROOM ELEVATOR C1-7 RESTROOM C1-5 MAINTENANCE C1-6 WAITING C1-2 RECEPTION C1-3 OFFICE C1-4 STAIRS STR1 STAIRS STR2 STAIRS STR3 CHUTE ROOM MECH / GARBAGE C1-9 ROOM COMMUNITY C1-8 (TYPE B) 2 BEDROOM A101 (TYPE B) 1 BEDROOM A103 (TYPE B) 1 BEDROOM A102 (TYPE B) 1 BEDROOM A104 (TYPE A) 2 BEDROOM A105 (TYPE B) 2 BEDROOM A110 (TYPE B) 2 BEDROOM A106 (TYPE B) 1 BEDROOM A108 (TYPE B) 1 BEDROOM A107 E N T R Y C 1 - 1 (TYPE A) 1 BEDROOM A109 A U T O M A T I C D O O R S C R E E N I N G 1 ℄ ℄ 3 3 3 3 3 3 RECESSED SLAB FD FDFD FDFD FDFD FDFD FDFD FD FD FD FD FD FD FD FD FD FD 1 A2.5 1 A2.6 1 A2.7 1 A2.8 STORAGE C1-10 1 A2.9 1 SIM A2.9 4 A2.9 1 A2.10 2 1 S C R E E N I N G