HomeMy WebLinkAboutC1.1ZONEAGRICULTURESUBURBANZONE M-2ZONEAGRICULTURESUBURBANZONE B-2ZONE PLIZONE R-4CP#52CP#51CP#50CP#53PROJECT SURVEY CONTROLPoint #50515253Northing134845.53135164.94135463.41135757.35Easting373324.39372868.41372476.46372086.59Elevation4643.614641.274640.064638.06DescriptionCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONPROJECT DATUM: THE BASIS OF BEARING FOR THIS SURVEY HAS BEENDERIVED FROM GPS OBSERVATIONS AND IS BASED ON A NAD 83,LAMBERT CONFORMAL CONIC, SINGLE PARALLEL, LOW DISTORTIONPROJECTION FOR THE CITY OF BOZEMAN; HAVING A POINT OF ORIGINAT 46°15'00" N LATITIUDE AND 111°15'00" W LONGITUDE WITH ASCALE FACTOR OF 1.000185. THE GRID TO GROUND COMBINED SCALEFACTOR IS 1.00000765; THE CONVERGENCE ANGLE IS 0°07'34".DISTANCES ARE INTERNATIONAL FEET (IFT). FOR THIS SURVEY GRIDDISTANCE IS ESSENTIALLY EQUAL TO GROUND DISTANCE.SURVEYED: 1/10/2019 BY: KSELECTRIC JUNCTION BOXTELEPHONESTORM DRAIN MANHOLECATCH BASINSIGNSANITARY SEWERSTORM DRAINPOWER POLEWATER VALVEFIRE HYDRANTFOUND CORNER MONUMENT AS NOTEDLEGENDGASPOWEROVERHEAD POWER LINETYPICALSET CORNER MONUMENT, REBAR WITH CAPBOLLARDBUSHCURB STOPFIRE DEPT. CONNECTIONGUYWIRESANITARY SEWER MANHOLESANITARY SEWER CLEAN OUTTELEPHONE PEDESTALTRANSFORMERCONIFEROUS TREEDECIDUOUS TREECOMMUNICATIONS BOXCOMMUNICATIONS PEDESTALEX. WELLEX. YARD HYDRANTFIBER OPTICWATEREXISTING GRADE CONTOURSDEMO AREA030SCALE:1:30_XREF601530SP-1 SUBMITTALNORTHNOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THEENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BESTRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OFBOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011, WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED INTHE STATE WHERE THE PROJECT IS LOCATED AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES ASARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTIONDESTINATION CENTER - PHASE 1
TOWNSHIP 1 S., RANGE 5 E., SECTION 26, P.M.M.
EXISTING TOPOGRAPHY AND DEMO PLAN
BILLINGS CLINIC BOZEMAN AMBULATORY
LOT 2A-1, MINOR SUBDIVISION 221F
BOZEMAN, MONTANAC1.1-
15063_02_EX_PROD.DWG
LMH
06/23/20 SP-1 SUBMITTAL
07/28/20
08/25/20
09/04/20
-
-
-
60% CD'S
90% CD'S
RESPONSE TO CITY
-
-
-
--
15063.03
P:\15063_03_Billings_Clinic_Ambulatory_Dest_Ctr\CADD_C3D\PRODUCTION_DWG\15063_02_EX_PROD.dwg, 9/4/2020 16:34:16, ARCH full bleed D (24.00 x 36.00 Inches), 1:1