Loading...
HomeMy WebLinkAboutA10 BLDG F G H & I ELEVATIONS 8-14-20COMPOSITE ROOF SHINGLES CEMENTITIOUS BOARD & BATTEN CEMENTITIOUS SHAKE SIDING SW7643 "PUSSYWILLOW GRAY" CEMENTITIOUS LAP SIDING -7" EXPOSURE SW7031 "MEGA GRIEGE" MATERIAL LEGEND CEMENTITIOUS LAP SIDING -7" EXPOSURE SW7032 "WARM STONE" CEMENTITIOUS PANEL SW 7643 "PUSSYWILLOW GRAY" STANDING SEAM METAL ROOF CONCRETE SPLIT -FACE CMU BLOCK B U I L D I N G H E I G H T 1 5 '-7 " 4" 1'-0" 4" 1'-0" 4" / 1 ' - 0 " 01 11 10 03 10 10 12 37 B U I L D I N G H E I G H T 1 5 '-7 " 4" 1'-0" 4" 1'-0" 4" / 1 ' - 0 " 37 12 03 10 01 11 10 B U I L D I N G H E I G H T 1 5 '-7 " 4" 1'-0" 4" 1'-0" 4" / 1 ' - 0 " 37 12 10 03 01 10 11 B U I L D I N G H E I G H T 1 5 '-7 " 4" 1'-0" 4" 1'-0" 4" / 1 ' - 0 " 28 10 37 01 03 10 11 10 12 B U I L D I N G H E I G H T 1 1 '-7 1 /8 " 1 1 / 2 " / 1 ' - 0 " 5.21 4.5 34 37 B U I L D I N G H E I G H T 1 1 '-6 " 1 1/2" 1'-0" 4.5 34 37 B U I L D I N G H E I G H T 1 1 '-6 " 1 1/2" 1'-0" 4.5 34 37 B U I L D I N G H E I G H T 1 1 '-6 " 8.12 34 4.5 37 42 45 43 42 45 43 1/4" 1'-0" 42 45 43 1/4" 1'-0" 42 43 43 B U I L D I N G H E I G H T 1 7 '-0 " 01 11 10 03 10 37 B U I L D I N G H E I G H T 1 7 '-0 " 11 01 12 03 01 11 10 03 10 37 B U I L D I N G H E I G H T 1 7 '-0 " B U I L D I N G H E I G H T 1 7 '-0 " 37 01 11 12 03 2555 WALNUT STREET DENVER, COLORADO 80205 www.kephart.com K E P H A R T community planning architecture CO P Y R I G H T © Project Architect Project Designer Date Job Number Drawn By Checked By Title Sheet Number 8/ 2 1 / 2 0 2 0 9 : 5 8 : 4 8 A M C: \ R e v i t L o c a l F i l e s \ 2 1 8 0 5 2 _ G r a f S t _ A p a r t m e n t s _ j e s s e g .r v t 21 3 1 G R A F 21 3 1 G R A F S T . BO Z E M A N , M T 5 9 7 1 8 20 2 0 DVL A10 DVL 30 AUGUST 2020 218052 SET SET BLDG F, G, H & I ELEVATIONS KEYNOTES NO. NOTE 01 COMPOSITE ASPHALT ROOF SHINGLES - OWENS CORNING "ESTATE GRAY" 03 CEMENTITIOUS BOARD & BATTEN SIDING (HARDIE PANEL HL5 AS BASIS OF DESIGN) - SHERWIN WILLIAMS SW7047 "PORPOISE" 4.5 8X8X16 CONCRETE MASONRY UNIT 5.21 STANDING SEAM METAL ROOF. 3N22 OR EQUIV. GALV. ROOF DECK ON 8X4X3/8 HSS PERIMETER BEAMS WELDED TO HSS6X6X1/4 CONCRETE FILLED STEEL COLUMNS 8.12 METAL PAN DECK - PRIMED AND PAINTED DARK BRONZE ON 3" SQUARE STEEL TUBE GATE FRAME W/ 3 PAIR STEEL HINGES 10 CEMENTITIOUS TRIM - SHERWIN WILLIAMS SW7516 "KESTREL WHITE" 11 PRE-MANUFACTURED METAL GUTTER - BERRIDGE "CHARCOAL GRAY" 12 PRE-MANUFACTURED METAL DOWNSPOUT - BERRIDGE "CHARCOAL GRAY" 34 CONCRETE CAP 37 CEMENTITIOUS ROOF FASCIA - SHERWIN WILLIAMS SW7516 "KESTRAL WHITE" 42 STEEL COLUMN - PER DESIGN BUILD 43 METAL CANOPY - PER DESIGN BUILD 45 METAL BEAM - PER DESIGN BUILD 1/8" = 1'-0" 1 PAVILLION FRONT ELEVATION - BLDG F 1/8" = 1'-0" 2 PAVILLION LEFT ELEVATION - BLDG F 1/8" = 1'-0" 3 PAVILLION RIGHT ELEVATION - BLDG F 1/8" = 1'-0" 4 PAVILLION REAR ELEVATION - BLDG F 1/8" = 1'-0" 8 TRASH ENCLOSURE - REAR ELEVATION - BLDG G 1/8" = 1'-0" 7 TRASH ENCLOSURE - RIGHT ELEVATION - BLDG G 1/8" = 1'-0" 6 TRASH ENCLOSURE - LEFT ELEVATION - BLDG G 1/8" = 1'-0" 5 TRASH ENCLOSURE - FRONT ELEVAVTION - BLDG G 1/8" = 1'-0" 9 CARPORT FRONT ELEVATION - BLDG H 1/8" = 1'-0" 10 CARPORT LEFT ELEVATION - BLDG H 1/8" = 1'-0" 11 CARPORT RIGHT ELEVATION - BLDG H 1/8" = 1'-0" 12 CARPORT REAR ELEVATION - BLDG H No. Date Issue 07.25.19 SDP SET 1 02.18.20 SDP RESUBMITTAL 2 08.14.20 SITE PLAN RESUBMITTAL 2 1/8" = 1'-0" 13 PAVILLION FRONT ELEVATION - BLDG I 1/8" = 1'-0" 14 PAVILLION LEFT ELEVATION - BLDG I 1/8" = 1'-0" 15 PAVILLION REAR ELEVATION - BLDG I 1/8" = 1'-0" 16 PAVILLION RIGHT ELEVATION - BLDG I 2