Loading...
HomeMy WebLinkAbout09-15-20 City Commission Packet Materials - A2. Cert of Appropriateness Deviation 423 S. Tracy App 2023120231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 1 of 22 20-231 Staff Report for the 423 S. Tracy Addition NCOA Certificate of Appropriateness Deviation Request Application Date: City Commission Public Hearing, September 15, 2020, 6:00pm Project Description: Certificate of Appropriateness to allow for a zoning deviation for the expansion of an existing carriage house/ dwelling-unit. The deviation specifically cited from the following Sections of the Bozeman Municipal Code (BMC): Section 38.320.030.C to allow an addition to an existing historic carriage house/ dwelling unit with 145 square feet within a front setback. Project Location: 423 S. Tracy Ave., FAIRVIEW ADD, S07, T02 S, R06 E BLOCK 1, LOT 10, BOZEMAN, MT. Recommendation: The application conforms to standards and is sufficient for approval. Recommended Motion for Deviation: “Having reviewed and considered the application materials, public comment, and all other information presented, I hereby find application 20- 231 meets the criteria required for approval and move to approve the 423 S. Tracy Addition application for a deviation request from Section 38.320.030.C of the Bozeman Municipal Code to allow for the construction of an addition to a carriage house/ dwelling unit with 145 square feet within a 15’ front setback, as shown in the application materials.” Report Date: Thursday, August 27, 2020 Staff Contacts: Phillipe Gonzalez, Associate Planner Agenda Item Type: Action (Quasi-judicial) EXECUTIVE SUMMARY Unresolved Issues None identified at this time Project Summary An applicant requested a zoning deviation from Section 38.320.030.C on July 17, 2020, the applicant Edwin Ugorowski and property owner Dave Scott, to allow the expansion of an existing carriage house/ dwelling unit within a 15’ front setback along West Story Street. The addition proposed will consist of additional living space on the first floor of the structure and increased front porch. The property is located in the R-2, Residential Zoning District and is a Contributing Property to the South Tracy/ South Black National Register Historic District as well as within the 239 Neighborhood Conservation Overlay District (NCOD). The property is located at the north corner of West Story Street and South Tracy Avenue. The property has two front setback requirements of 15’ per Section 38.320.030.C BMC. The property currently has two structures a primary residence that fronts along South Tracy and a carriage house, currently used as an additional dwelling unit, fronted along West Story Street in the rear of the lot. Pursuant to Section 38.200.010.A.1.k BMC, the City Commission retains to itself under all circumstances the review of any deviation request where the deviation is for more than 20% of the standard. The proposed work as mentioned includes the expansion of the existing carriage house along the first floor and expanded front porch. Addition is proposed to encroach at an additional 145 square feet, porch is proposed to encroach up to 1’-8” from south property line. No proposed construction will encroach into the public ROW. The proposed expanded carriage house requires a deviation more than 20% of the standard, and therefore requires review and decision by the City Commission. Section 38.340.050.A. BMC, Standards for certificates of appropriateness, states that all work performed in completion of an approved certificate of appropriateness must be in conformance with the most recent edition of the Secretary of the Interior's (SOI) Standards for the Treatment of Historic Properties with Guidelines for Preserving, Rehabilitating, Restoring and Reconstructing Historic Buildings, published by U.S. Department of the Interior, National Park Service, Cultural Resource Stewardship and Partnerships, Heritage Preservation Services, Washington, D.C. This application falls under the SOI Standards for Rehabilitation, defined as “the act or process of making possible a compatible use for a property through repair, alterations, and additions while preserving those portions or features which convey its historical, cultural, or architectural values.” For this application, staff evaluation of the SOI standards is in Section 7 of this report concludes that the rehabilitation of the historic property with additions meets the definition of Rehabilitation under the SOI and is supported by staff. Section 38.340.050.B BMC, lists the architectural design guidelines used to consider the appropriateness and compatibility of proposed alterations with original design features of existing structures or properties, and with neighboring structures or properties. The review authority must also be guided by the design guidelines for the neighborhood conservation overlay district to determine whether the proposal is compatible with any existing or surrounding structures. A description of the NCOD Guidelines review criteria and staff - evaluation is in Section 7 of this report. Staff finds that the proposed expansion of the existing historic carriage house meets the criteria in this section including height, proportions of doors and windows, relationship of buildings masses and spaces, roof shape, scale, directional expression, and materials. Additional criteria from Section 38.340.050 BMC including C, D, E, and F are detailed below in Section 7. 240 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 3 of 22 The application must also meet the standards for granting deviations in Section 38.340.070, BMC. A description and staff evaluation of these standards is in Section 7 of this report. Staff concludes that the rehabilitation work on the historic property meets all criteria for granting a deviation and that the modifications are more historically appropriate for the building and site in question and the adjacent properties, as determined by the standards in section 38.340.050 BMC, than would be achieved under a literal enforcement of Chapter 38. No public comment has been received as of writing this staff report. Conditions of Approval 1. None Alternatives 1. Approve the application with the following motion: “Having reviewed and considered the application materials, public comment, and all other information presented, I hereby find application 20-231 meets the criteria required for approval and move to approve the 423 S. Tracy Addition application for a deviation request from Section 38.320.030.C of the Bozeman Municipal Code to allow for the construction of an addition to a carriage house/ dwelling unit with 145 square feet within a 15’ front setback, as shown in the application materials.” 2. Open and continue the public hearing on the application, with specific direction to staff or the applicant to study additional information or to address specific items. 3. Deny the application after making alternative findings regarding the application’s lack of compliance with standards. 241 TABLE OF CONTENTS EXECUTIVE SUMMARY .............................................................................................................. 1 Unresolved Issues ............................................................................................................... 1 Project Summary ................................................................................................................. 1 Conditions of Approval ....................................................................................................... 3 Alternatives ......................................................................................................................... 3 TABLE OF CONTENTS................................................................................................................. 4 SECTION 1 - MAP AND PLAN SERIES ......................................................................................... 5 SECTION 2 – EXISITNG AND PROPOSED SITE PLAN .................................................................. 6 SECTION 3 – PHOTO ELEVATIONS ........................................................................................... 10 SECTION 4 – PROPOSED ELEVATIONS ..................................................................................... 11 SECTION 5 - REQUESTED DEVIATION(S) .................................................................................. 14 SECTION 6 - RECOMMENDATION AND FUTURE ACTIONS ...................................................... 14 SECTION 7 - STAFF ANALYSIS AND FINDINGS ......................................................................... 14 Applicable Plan Review Criteria ........................................................................................ 15 APPENDIX A – PROJECT SITE ZONING AND GROWTH POLICY ................................................ 20 APPENDIX B – DETAILED PROJECT DESCRIPTION AND BACKGROUND ................................... 21 APPENDIX C – NOTICING AND PUBLIC COMMENT ................................................................. 21 APPENDIX D – OWNER INFORMATION AND REVIEWING STAFF ............................................ 21 FISCAL EFFECTS ....................................................................................................................... 22 ATTACHMENTS ........................................................................................................................ 22 242 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 5 of 22 Section 1- MAP AND PLAN SERIES 243 SECTION 2 – EXISITNG AND PROPOSED SITE PLAN Figure 2. Existing Site Plan 244 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 7 of 22 Figure 3. Proposed Site Plan 245 Figure 4. Proposed Site Plan 246 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 9 of 22 Figure 5. Existing and Proposed Floor Plan 247 SECTION 3 – PHOTO ELEVATIONS Figure 6. Existing South Elevation Figure 7. Existing East Elevation 248 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 11 of 22 Figure 8. Existing West Elevation Figure 9. Existing North Elevation 249 SECTION 4 – EXISITNG AND PROPOSED ELEVATIONS Figure 10. Proposed South Elevation Figure 11. Proposed East Elevation 250 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 13 of 22 Figure 12. Proposed North Elevation 251 SECTION 5 – REQUESTED DEVIATION(S) The applicant has submitted a zoning deviation request for Section 38.320.030.C BMC to allow for an expansion of the historic carriage house/ dwelling unit. The proposed work along the east and south facades will be competed along the first floor only. The expansion of the living area and front porch within the front setback of 15’ will total 145 square feet. The expanded front porch will lay 1’-8” from the southern property line. The applicant argues that the proposed additions will create better flexibility with the existing structure while maintaining the historic structure commonly seen throughout the neighborhood, completed in similar architectural details to the existing porch and structure. The applicant argues that the addition is limited in size by following the first floor in order to minimize the addition. SECTION 6 – RECOMMENDATIONS AND FUTIRE ACTIONS The proposed application and associated deviation request requires the review and decision of the City Commission. The City Commission retains to itself under all circumstances the review of any deviation request where the deviation is for more than 20% of the standard. Staff’s position is that the application conforms to standards and is adequate for approval. Staff has made positive findings for all deviation criteria and believes the proposed additions are historically appropriate as they are elements that are seen within the Historic District and do not detract or minimize the significance of the historic carriage house. The City Commission will consider the proposal on September 15, 2020. The meeting will EITHER be held in person in the City Commission Room, City Hall, 121 N. Rouse Avenue Bozeman, MT, OR be held using WebEx, an online video conferencing system. The agenda for the meeting will specify location of the meeting. SECTION 7 – STAFF ANALYSIS AND FINDINGS Staff’s analysis and resulting recommendations are based on the entirety of the application materials, municipal codes, standards, and plans, public comment, and all other materials available during the review period. Collectively this information is the record of the review. The analysis in this report is a summary of the completed review. Historic Context & Architectural Description 423 S. Tracy was inventoried in the 1983/84 architecture survey in Bozeman completed by James R. McDonald Architects PC. The single detached house is 2 stories built and occupied by Fred C. Jacobs, 1904-1912. The house and carriage-house both are recorded on Sanborn Maps starting in 1912. The footprint of the carriage house shows the historic original form prior to 252 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 15 of 22 the non-historic addition currently seen as the one story addition and porch. The Sanborn map shows the carriage house with a large ‘X’ illustrating it operated as a stable. In 1999 the property owners applied for a Deviation COA to construct the existing addition along the eastern façade, a 1-1/2 story addition with a porch facing the south. The Deviation was approved July 30, 1999 and the addition constructed as seen today. Applicable Plan Review Criteria The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or State law. In considering applications for plan approval, the review authority and advisory bodies evaluate the following criteria. This application must be reviewed for compliance with all applicable requirements of this BMC chapter including overlay district requirements. The staff findings are analyzed under the following: Code Standard Meets Standards? Secretary of Interior’s (SOI) Standards for Restoration of Historic Properties Yes BMC 38.340.050 Standards for Certificate of Appropriateness Yes BMC 38.340.070 Criteria for Granting Deviations Yes Secretary of Interior’s Standards for The Treatment of Historic Properties – Guidelines for Restoration The National Park Service guidelines for working on historic structures provides standards for Rehabilitation as a treatment that should be followed when the expressed goal of the project is to make compatible uses for a property through repair, alterations and additions. The guidelines list 10 standards for rehabilitation; these have been evaluated individually by staff below: 1. A property will be used as it was historically or be given a new use that requires minimal change to its distinctive materials, features, spaces and spatial relationships. Not Applicable, the use has not changed. 2. The historic character of a property will be retained and preserved. The removal of distinctive materials or alterations of features, spaces, and spatial relationships that characterize a property will be avoided. The proposed additions will be constructed along the non-historic portion of the structure. 253 3. Each property will be recognized as a physical record of its time, place and use. Changes that create a false sense of historical development, such as adding conjectural features or elements from other historic properties, will not be undertaken. Additions will mimic historic style architectural features that are present on the existing structure. 4. Changes to a property that have acquired historic significance in their own right will be retained and preserved. Not Applicable, only modification is to the non-historic portion of the structure. 5. Distinctive materials, features, finishes and construction techniques or examples of craftsmanship that characterize the restoration period will be preserved. Not applicable, the historic structure had been previously rehabilitated and is not part of the scope of this project. 6. Deteriorated historic features will be repaired rather than replaced. Where the severity of deteriorating requires replacement of a distinctive feature, the new feature will match the old in design, color, texture, and, where possible, materials. Replacement of missing features will be substantiated by documentary and physical evidence. Not applicable, the historic portion of the structure is not part of the scope of this project. 7. Chemical or physical treatments, if appropriate, will be undertaken using the gentlest means possible. Treatments that cause damage to historic materials will not be used. Not applicable, no chemical or physical treatments are being undertaken. 8. Archeological resources will be protected and preserved in place. If such resources must be disturbed, mitigation measures will be undertaken. Not applicable, underground archaeological resources do not apply to this project. 9. New additions, exterior alterations, or related new construction will not destroy historic materials, features, and spatial relationships that characterize the property. The new work will be differentiated from the old and will be compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment. The new addition proposed has been designed to attach to the non-historic portion of the structure, protecting the historic façade from losing historic materials and features. The addition will continue along the single story and will maintain the spatial relationship between the historic form and non-historic additions. 10. New Additions and adjacent or related new construction will be undertaken in such a manner that, if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired. If the addition where to be removed it would have a minimal impact on the historic structure as it is connected by a non-historic portion. In summary, staff finds that the proposed addition do not significantly impact the historic carriage house, the addition is designed to replicate the previous addition and will integrate into the architectural style of the carriage-house, existing home and the South Black/ South Tracy Historic District. The additions will result in a no loss of historic materials, no character 254 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 17 of 22 defining features will be destroyed, obscured or damaged. Additionally the additions are proposed on a secondary or non-character defining elevation and limited in size and scale to the historic structure. Standards for Certificate of Appropriateness In compliance with Section 38.340.050 BMC – Standards for certificates of appropriateness. The staff review considered criteria A-F when reviewing the COA application for the carriage house addition, staff has individually evaluated the criteria below: A. All work performed in completion of an approved certificate of appropriateness must be in conformance with the most recent edition of the Secretary of the Interior's (SOI) Standards for the Treatment of Historic Properties with Guidelines for Preserving, Rehabilitating, Restoring and Reconstructing Historic Buildings, published by U.S. Department of the Interior, National Park Service, Cultural Resource Stewardship and Partnerships, Heritage Preservation Services, Washington, D.C. (available for review at the community development department). The proposed additions meet the SOI Standards for Rehabilitation. B. Architectural appearance design guidelines used to consider the appropriateness and compatibility of proposed alterations with original design features of subject structures or properties, and with neighboring structures and properties, must focus upon the following: 1. Height; Carriage house addition is proposed to be shorter in height than the historic structure, respecting the original form minimizing the visual impacts. 2. Proportions of doors and windows; Proposed windows and doors on new construction continues the existing architectural style and proportions of windows on the historic home and neighborhood. 3. Relationship of building masses and spaces; Carriage house addition is smaller in mass from the historic carriage house, breaking up the mass of the structure and allowing the carriage house to maintain its historic form. 4. Roof shape; Proposed roof shapes continue existing cross gabled roof shapes seen on the non-historic addition and commonly seen within the historic district. 5. Scale; Carriage house addition maintains a building scale is small and seen throughout the Historic District. 6. Directional expression, with regard to the dominant horizontal or vertical expression of surrounding structures; Carriage house addition maintains the existing directional expression of the historic structure continuing a similar footprint and horizontal orientation. 255 7. Architectural details; Proposed carriage house addition continues the use of architectural details found on the existing historic house and historic carriage house such as horizontal lap siding, decorative brackets and one-over-one sash windows. 8. Concealment of non-period appurtenances, such as mechanical equipment; and Not applicable, no proposed non-period appurtenances. 9. Materials and color schemes (any requirements or conditions imposed regarding color schemes must be limited to the prevention of nuisances upon abutting properties and prevention of degradation of features on the property in question. Color schemes may be considered as primary design elements if a deviation from the underlying zoning is requested). Proposed materials for additions such as wood, composite materials and vinyl are appropriate for new construction and additions and are found throughout the South Black/ South Tracy Historic District. C. Contemporary, non-period and innovative design of new structures and additions to existing structures is encouraged when such new construction or additions do not destroy significant historical, cultural or architectural structures or their components and when such design is compatible with the foregoing elements of the structure and surrounding structures. The applicant has proposed additions that are similar in architectural design as the existing historic home and historic carriage house, the additions do not destroy significant historical, cultural or architectural structures on the existing site. D. When applying the standards of subsections A through C of this section, the review authority must be guided by the design guidelines for the neighborhood conservation overlay district (NCOD). Application of the design guidelines may vary by property as explained in the introduction to the design guidelines. When reviewing a contemporary, non-period, or innovative design for new structures or additions to existing structures, the review authority must be guided by the design guidelines for the neighborhood conservation overlay district to determine whether the proposal is compatible with any existing or surrounding structures. Chapter 1 of the Design Guidelines for the Historic Preservation and the NCOD Additions to Residential Properties policy States, “When planning an addition to an existing building, consider the effect it will have on the structure. The following guidelines avoid any negative impacts of an addition: while the choice of a style is not a concern of these principles, there is an awareness that each property has some style that helps define its character. Additions that reflect elements of the existing predominant style reinforce the positive character. Those 256 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 19 of 22 elements that seem unintentional foreign to the individual property and detract from the overall design should be minimized and not considered positive elements to base the design of an addition on.” The applicant has proposed an addition that mimics the existing architectural style of the existing carriage house elements creating an integrated transition between the historic portion and new construction. E. Conformance with other applicable development standards of this chapter. Development in the NCOD must comply with all other applicable development standards of this chapter. The proposed additions do not comply with Section 38.320.030.C BMC, and thus a deviation has been requested from the 15’ front setback. F. Tax abatement certificate of appropriateness applications are also reviewed with the procedures and standards established in chapter 2, article 6, division 2. NA, tax abatement was not requested in the application. In summary, staff finds that based on the above criteria, the proposed carriage house addition meets the standards for Certificate of Appropriateness. Criteria for Granting Deviations Pursuant to Section 38.340.070 BMC, there are three criteria for granting deviations from the underlining zoning requirement. 1. Modifications must be more historically appropriate for the building and site in question and the adjacent properties, as determined by the standards in Section 38.340.050, than would be achieved under a literal enforcement of this chapter. The proposed additions submitted by the applicant as referenced in the application represent a continued use of the property as a residence, while increasing the living space to increase the flexibility of the property by constructing additions along the historic structure, within the required 15’ front setback. In reviewing the SOI preservation standards, City code, and the NCOD Design Guidelines for Historic Preservation, staff supports the applicant’s argument that the proposed addition meets Criteria 1 for Granting Deviations and have been outlined in this report and are summarized below: • Secretary of Interior’s (SOI) Standards for Rehabilitation of Historic Properties: While much of these guidelines are focused on repairing, stabilizing, and preserving historic architecture, this section does provide important guidance on appropriate additions to historic structures. The SOI Standards for Rehabilitation support the need for the potentiality of additions in order to keep historic structure agile in changing needs and uses of the property. • The Bozeman Design Guidelines for Historic Preservation and the Neighborhood Conservation Overlay District, 2006, outlines the guidelines for development within the NCOD and Historic Districts. Within the Introduction the Guidelines state in 257 regards to alterations, “This tradition of alterations is anticipated to continue. It is important, however, that new alterations be designed in such a manner that they preserve the historic character of the primary structure.” • Criteria for Certificate of Appropriateness: When reviewing against standards A-F staff found that all criteria except F were applicable to this application. Criteria A-D are summarized above. Criteria B contains the architectural design guidelines. Staff found that the project meets all three of the standards that are applicable to the proposed additions. Criteria E-F are detailed above. 2. Modifications will have minimal adverse effects on abutting properties or the permitted uses thereof. The proposed additions will have minimal adverse effects on abutting properties. The current historic carriage house lies along the south property line, on a corner lot. 3. Modifications must assure the protection of the public health, safety and general welfare. Approvals may be conditioned to assure such protection, and such conditions may include a time period within which alterations will be completed; landscaping and maintenance thereof; architectural, site plan and landscape design modifications, or any other conditions in conformity with the intent and purpose set forth in this part 1. Staff has not identified any potential issues related to public health, safety and general welfare as it related to the proposed application. APPENDIX A – PROJECT SITE ZONING AND GROWTH POLICY Zoning Designation and Land Uses: The subject property is zoned R-2 (Residential Moderate Density District). The intent of the R-2 residential moderate density district is to provide for one-and two-household residential development at urban densities within the city in areas that present few or no development constraints. These purposes are accomplished by: 1. Providing for minimum lot sizes in developed areas consistent with the established development patterns while providing greater flexibility for clustering lots and housing types in newly developed areas. 2. Providing for community facilitates to serve such development while respecting the residential quality and nature of the area. Use of this zone is appropriate for areas with moderate access to parks, community service and/ or transit. Adopted Growth Policy Designation: Residential: This category designates places where the primary activity is urban density dwellings. Other uses which complement residences are also acceptable such as parks, low intensity home based occupations, fire stations, churches, and schools. High density residential areas should be established in close proximity to commercial centers to facilitate the provision of services and employment opportunities to persons without 258 20231 Staff Report for 423 S. Tracy Addition NCOA/Deviation Page 21 of 22 requiring the use of an automobile. Implementation of this category by residential zoning should provide for and coordinate intensive residential uses in proximity to commercial centers. The residential designation indicates that it is expected that development will occur within municipal boundaries, which may require annexation prior to development. The dwelling unit density expected within this classification varies between 6 and 32 dwellings per net acre. A higher density may be considered in some locations and circumstances. A variety of housing types can be blended to achieve the desired density. Large areas of single type housing are discouraged. In limited instances the strong presence of constraints and natural features such as floodplains may cause an area to be designated for development at a lower density than normally expected within this category. All residential housing should be arranged with consideration of compatibility with adjacent development, natural constraints such as watercourses or steep slopes, and in a fashion which advances the overall goals of the Bozeman growth policy. The residential designation is intended to provide the primary locations for additional housing within the planning area. APPENDIX B – DETAILED PROJECT DESCRIPTION AND BACKGROUND A zoning deviation from Section 38.320.030.C BMC was requested on July 17, 2020 by the applicant Edwin Ugorowski and property owner Dave Scott, to construct an addition to the existing carriage house in the rear of the lot. The addition is proposed along the east and south façade, addition totals 145 sqft within the front setback. Proposed design has front porch up to 1’-8” from south property line. No part of addition will encroach into public right-of-way. The property is located in the R-2, Residential Moderate Density District, Neighborhood Conservation Overlay District (NCOD), and the South Tracy/ South Black Historic District. Pursuant to Section 38.200.010 of the Bozeman Municipal Code, the City Commission retains itself under all circumstances the review of any deviation request where the deviation is for more than 20% of the standard. APPENDIX C – NOTICING AND PUBLIC COMMENT Noticing was provided pursuant to Section 38.40.030, BMC. Notice was sent to property owners within 200 feet of the exterior boundaries of the property via USPS first class mail on August 26, 2020 which was at least 15 and not more than 45 days prior to the expected decision by the City Commission. Notice was published in the Bozeman Daily Chronicle on August 30 and September 06. A 24” x 36” notice sign was posted on site on August 30, 2020. No public comment has been received as of writing this staff report. APPENDIX D – OWNER INFORMATION AND REVIEWING STAFF Owner/Applicant: Dave Scott, 423 S. Tracy Ave., Bozeman MT 59715 259 Representative: Edwin Ugorowski, 37 East Main, Bozeman, MT 59715 Report By: Phillipe Gonzalez, Historic Preservation Specialist FISCAL EFFECTS No unusual fiscal effects have been identified. No presently budgeted funds will be changed by this application. ATTACHMENTS The full application and file of record (#20231) can be viewed at the Bozeman Community Development Department at 20 E. Olive Street, Bozeman, MT 59715. Application Documents Application Plans 260 261 DEVELOPMENT REVIEW APPLICATION 1. PROPERTY OWNER Name: Full address (with zip code): Phone: Email: 2. APPLICANT Name: Full address (with zip code): Phone: Email: 3. REPRESENTATIVE Name: Full address (with zip code): Phone: Email: 4. SPECIAL DISTRICTS Overlay District: Neighborhood Conservation None Urban Renewal District: Downtown North 7th Avenue Northeast North Park None 5. CERTIFICATIONS AND SIGNATURES This application must be signed by both the applicant(s) and the property owner(s) (if different) for all application types before the submittal will be accepted. The only exception to this is an informal review application that may be signed by the applicant(s) only. As indicated by the signature(s) below, the applicant(s) and property owner(s) submit this application for review under the terms and provisions of the Bozeman Municipal Code. It is further indicated that any work undertaken to complete a development approved by the City of Bozeman shall be in conformance with the requirements of the Bozeman Municipal Code and any special conditions established by the approval authority. I acknowledge that the City has an Impact Fee Program and impact fees may be assessed for my project. Further, I agree to grant City personnel and other review agency representative’s access to the subject site during the course of the review process (Section 38.34.050, BMC). I (We) hereby certify that the above information is true and correct to the best of my (our) knowledge. Certification of Completion and Compliance – I understand that conditions of approval may be applied to the application and that I will comply with any conditions of approval or make necessary corrections to the application materials in order to comply with municipal code provisions. Statement of Intent to Construct According to the Final Plan – I acknowledge that construction not in compliance with the approved final plan may result in delays of occupancy or costs to correct noncompliance. continued on next page Development Review Application A1 Page 2 of 3 Revision Date: 5.16.18 REQUIRED FORMS: Varies by project type, PLS 'DYH 6FRWW  6 7UDF\ $YH %R]HPDQ 07   GDYLG#VODEZRUNVRIPRQWDQDFRP 'DYH 6FRWW  6 7UDF\ $YH %R]HPDQ 07   GDYLG#VODEZRUNVRIPRQWDQDFRP (GZLQ 8JRURZVNL  (DVW 0DLQ 6W 6XLWH  %R]HPDQ 0W   (GZLQ#GHVLJQSDUWQHUVKLSFRP 262 263 264 Page 2 of 2 4-8-20 Printed Name: Owner Signature Printed Name: If signing as a corporation or LLC, please provide the title and position of the individual signing on behalf of the corporation/LLC. Attach separate sheets for additional owner signatures. Dave Scott 265 266 267 268 269 Elevations Min-Max Sizing & Formulas ...................................................................................................2 Egress Chart ..........................................................................................................................3 Single Units: Standard Sizing ...............................................................................................................4 Nominal Sizing .................................................................................................................6 Geometric Insash Transom: Standard Sizing ...............................................................................................................8 Nominal Sizing .................................................................................................................9 270 Product Prefix Suffix Frame Width Frame Height W-2500 Clad-Wood Double-Hung - W-2500 Clad-Wood Double-Hung - Nominal N W-2500 Clad-Wood Geometric Insash Transom - W-2500 Clad-Wood Geometric Insash Transom - Nominal N 25CDH 25CDHT WW HH Rough Opening (Frame Width + 3/4") x (Frame Height + 3/4") Daylight Opening per Sash ft2 ((Frame Width - 5 5/16") x (Frame Height / 2 - 3 5/16")) / 144 Clear Opening ft2 ((Frame Width - 3 9/16") x (Frame Height / 2 - 3 5/8")) / 144 Masonry Opening (Frame Width + 1/2") x (Frame Height + 1/2") Formulas 271 21 3/8'' 25 3/8'' 29 3/8'' 33 3/8'' 37 3/8'' 41 3/8'' 36'' 1.77 ft² 2.17 ft² 2.57 ft² 2.97 ft² 3.37 ft² 3.77 ft² 40'' 2.02 ft² 2.48 ft² 2.93 ft² 3.38 ft² 3.84 ft² 4.29 ft² 48'' 2.52 ft² 3.08 ft² 3.65 ft² 4.21 ft² 4.78 ft² 5.34 ft² 52'' 2.76 ft² 3.39 ft² 4.01 ft² 4.63 ft² 5.25 ft² 5.87 ft² 56'' 3.01 ft² 3.69 ft² 4.36 ft² 5.04 ft² 5.72 ft² 6.39 ft² 60'' 3.26 ft² 3.99 ft² 4.72 ft² 5.46 ft² 6.19 ft² 6.92 ft² 64'' 3.51 ft² 4.29 ft² 5.08 ft² 5.87 ft² 6.66 ft² 7.44 ft² 68'' 3.75 ft² 4.60 ft² 5.44 ft² 6.28 ft² 7.13 ft² - 72'' 4.00 ft² 4.90 ft² 5.80 ft² 6.70 ft² 7.60 ft² - 76'' 4.25 ft² 5.20 ft² 6.16 ft² 7.11 ft² 8.07 ft² - Single Units Indicates that the unit meets egress specifications. Clear opening must meet or exceed 20" width, 24" height, and 5.7 ft². The number inside indicates the clear opening square footage. Width Height19 1/4'' 23 1/4'' 27 1/4'' 31 1/4'' 35 1/4'' 35 1/4'' 1.52 ft² 1.91 ft² 2.30 ft² 2.69 ft² 3.07 ft² 41 1/4'' 1.85 ft² 2.32 ft² 2.79 ft² 3.26 ft² 3.73 ft² 47 1/4'' 2.18 ft² 2.73 ft² 3.29 ft² 3.84 ft² 4.39 ft² 53 1/4'' 2.50 ft² 3.14 ft² 3.78 ft² 4.42 ft² 5.06 ft² 59 1/4'' 2.83 ft² 3.55 ft² 4.27 ft² 4.99 ft² 5.72 ft² 65 1/4'' 3.16 ft² 3.96 ft² 4.77 ft² 5.57 ft² 6.38 ft² 71 1/4'' 3.48 ft² 4.37 ft² 5.26 ft² 6.15 ft² 7.04 ft² Single Units - Nominal Indicates that the unit meets egress specifications. Clear opening must meet or exceed 20" width, 24" height, and 5.7 ft². The number inside indicates the clear opening Width Height272 273 274 275 276 277 278 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 279 PROJECT NAME: SCOTT, DAVE C 423 S TRACY DPI PROJECT NO: 20-SDC CONTIGUOUS MAP OWNER NAME PROPERTY ADDRESS OWNER ADDRESS (If blank use property address) 1 SANTOS, PETER & CHERYL 419 S TRACY AVE BOZEMAN, MT 59715-5277 1398 CHELSEA DRIVE LOS ALTOS, CA 94024 SEE ATTACHED CADASTRAL IMAGE FOR MAP 280 281 PROJECT NAME: SCOTT, DAVE C 423 S TRACY DPI PROJECT NO: 20-SDC ADJOINERS NOT CONTIGUOUS MAP OWNER NAME PROPERTY ADDRESS OWNER ADDRESS (If blank use property address) 2 BELL, WILLIAM & CHRISTINE 415 S TRACY AVE BOZEMAN, MT 59715-5277 3 POCOCK, LISA M & MATTHEW S 407 S TRACY AVE BOZEMAN, MT 59715-5277 4 RISING OAKS LLC 405 S TRACY AVE BOZEMAN, MT 59715-5277 PO BOX 61239 PALO ALTO, CA 94306-6239 5 CASTLS MT1 LLC 401 S TRACY AVE BOZEMAN, MT 59715-5277 233 ALTA VISTA DR BOZEMAN, MT 59715-8106 6 ATTICUS PRIME LLC 420 S WILLSON AVE BOZEMAN, MT 59715-5235 7 BOZEMAN, THOMAS E; HEBERT, PAMELA J 412 S WILLSON AVE BOZEMAN, MT 59715-5235 8 PALMER, LANCE & LORI 408 S WILLSON AVE BOZEMAN, MT 59715-5235 9 SARIKAYA, NECLA 404 S WILLSON AVE BOZEMAN, MT 59715-5235 10 BLUE STEEL PARTNERS LLC 404 S TRACY AVE BOZEMAN, MT 59715-5277 PO BOX 1584 BOZEMAN, MT 59771-1584 11 HORSWILL, RICHARD K & BEATRICE L 412 S TRACY AVE BOZEMAN, MT 59715-5277 12 416 TRACY LLC 416 S TRACY AVE BOZEMAN, MT 59715-5277 428 N 7TH AVE BOZEMAN, MT 59715-3310 13 CIARI KATE REGAN REV LIV TRUST 420 S TRACY AVE BOZEMAN, MT 59715-5276 14 TALBOT, GEORGE H 424 S TRACY AVE BOZEMAN, MT 59715-5276 15 KEMPISTY, BRIAN D 430 S TRACY AVE BOZEMAN, MT 59715-5276 733 S TRACY AVE BOZEMAN, MT 59715-5323 16 TURRENTINE, MARILOU; WILSON, DAVID E 436 S TRACY AVE BOZEMAN, MT 59715-5276 1715 FIR CREST CT BOZEMAN, MT 59715-7413 17 BOSSENBROOK, MARK A 502 S TRACY AVE BOZEMAN, MT 59715-5278 18 STRICH WESTPHAL, PAMELA BETH 519 S TRACY AVE BOZEMAN, MT 59715-5279 19 WARD, MARGARET M 513 S TRACY AVE BOZEMAN, MT 59715-5279 20 MALLOY, ROBERT W JR & DENISE G 509 S TRACY AVE BOZEMAN, MT 59715-5279 30 SOUTH ST PITTSFORD, NY 14534-2045 21 MAXTED, FREDERICK J III TRUSTEE 505 S TRACY AVE BOZEMAN, MT 59715-5279 22 HODGSON, MARK G & CHRISTINE R 501 S TRACY AVE BOZEMAN, MT 59715-5279 23 LOLI FAMILY TRUST; ANDREWS, AMY L 504 S WILLSON AVE BOZEMAN, MT 59715-5237 24 STRAUS, KENNETH M & TIMOTHY A 516 S WILLSON AVE BOZEMAN, MT 59715-5237 25 MCBEE, BRANNIN; BENNETT, MEGHAN 520 S WILLSON AVE BOZEMAN, MT 59715-5237 SEE ATTACHED CADASTRAL IMAGE FOR MAP 282 1. Project Narrative The project consists of a remodel plus addition to the additional dwelling unit/carriage house at 423 S Tracy Avenue, in the South Tracy-South Black Historic district, constructed circa 1910. The new floor plan will move the existing living room wall to the east to support the second floor balcony. The covered porch will enlarge and wrap around the east side of the building, the south side of the porch will encroach on the property easement, detailed in the deviation per Sec 38.250.050. The current main floor square footage of the carriage house is approximately 442, with 84 square feet of exterior storage. The addition will increase the square footage of the carriage house by 91 square feet (~5%). The remodel will switch some exterior storage space into interior space. The proposed square footage will be 569 of livable and 48 of exterior storage. All of the remodeling and addition will occur on the east side of the carriage house. No changes will be made to the west side of the carriage house. 2. Historical information See attached Historical Inventory. The removal and alterations in this project touch upon the least historically relevant aspects of the carriage house. The addition of the covered porch and hip roof will add to the historically accurate aspects of the carriage house as well as duplicate the porch of the main house. 3. Elevation pictures 4. Site plans 5. Elevation diagrams 6. Elements to be removed or altered Checklist items 3, 5 and 11 (before/after floor plans 2.1, 2.2 and 2.3, existing elevation pictures 3.1 and 3.2, and planned elevations 3.3 and 3.4) indicate which elements are to be removed, replaced or added. 7. Demolition analysis for non-conforming - NOT APPLICABLE 8. Infill context study - NOT APPLICABLE 9. Window/door changes & replacements A schedule of window changes and additions is included in the new floor plan drawing 2.3. 283 10. Window cut sheets The project will utilize JeldWen W2500 double-hung and awning windows. A V2500 brochure and the double-hung and awning spec sheets are attached, with filenames as below: JW w2500 brochure.pdf JW w2500 Awning.pdf JW w2500 DH.pdf 11. Floor plans See attached before and after floor plan drawings 2.1, 2.2 and 2.3. 12. Parking plan - NOT APPLICABLE (no bedrooms being added) 13. Schedule of phased project - NOT APPLICABLE 14. Neighborhood commentary summary - NOT APPLICABLE (not a major project such as new home) 15. Deviation a. The roof & elevation of the addition on the east side will be a traditional wrap around hip roof over the covered porch, mirroring the design of the main house on the property. The living room windows will be replaced with double hung JeldWen windows that mirror the traditional look of the main house. The second floor windows on the east wall will be replaced with classic French doors to the balcony. Both these changes will add to the historical significance of the carriage house. b. Modifications will not have any adverse effects on neighboring properties. c. The addition will not have a negative impact on public health or safety. d. The remodel adding a partial wrap around porch will contribute to the historic character of the community. 16. Shown in Site Plan 17. Shown in Elevations 284 285 286 287 288 289 290 291