Loading...
HomeMy WebLinkAboutG1.2 General Notes 04.23.2020PR O J E C T D E S C R I P T I O N 1. D E S I G N A N D C O N S T R U C T I O N O F A 3 S T O R Y O F F I C E L E A S E BU I L D I N G . M E T A L F R A M E S T R U C T U R E W I T H M E T A L F R A M I N G A N D CO N C R E T E F O U N D A T I O N . AP P L I C A B L E C O D E S 20 1 2 I N T E R N A T I O N A L E N E R G Y C O N S E R V A T I O N C O D E 20 1 8 I N T E R N A T I O N A L B U I L D I N G C O D E 20 1 8 I N T E R N A T I O N A L F U E L G A S C O D E 20 1 7 N A T I O N A L E L E C T R I C A L C O D E 20 1 8 U N I F O R M P L U M B I N G C O D E 20 1 8 I N T E R N A T I O N A L M E C H A N I C A L C O D E AN S I A 1 1 7 . 1 - 2 0 0 3 PR O J E C T I N F O & C O D E A N A L Y S I S : ZO N I N G S U M M A R Y REQUIRED PLUMBING JU R I S D I C T I O N : C I T Y O F B O Z E M A N ZO N I N G : B 2 - B O Z E M A N G A T E W A Y P U D *A L L O W A B L E B L D G . H E I G H T : 6 5 F E E T BU I L D I N G L O T A R E A : 1 3 , 1 0 8 S F , 0 . 3 0 A C R E S LE G A L L O T A R E A A L L O W E D ( C O D E R E F E R E N C E ) : FU L L C O V E R A G E O F B L O C K EX C E P T F O R Y A R D S E T B A C K S YA R D S E T B A C K S ( C O D E R E F E R E N C E ) : FR O N T Y A R D : 1 5 F T . SI D E Y A R D : 1 0 F T . BA C K Y A R D : 1 0 F T . DESCRIPTION MAIN LEVEL WATER CLOSETS LAVATORIES DRINKING FOUNTAINS SECOND LEVEL WATER CLOSETS LAVATORIES DRINKING FOUNTAINS THIRD LEVEL WATER CLOSETS LAVATORIES DRINKING FOUNTAINS US E A N D O C C U P A N C Y : BU I L D I N G H E I G H T A N D A R E A : TY P E O F C O N S T R U C T I O N : OC C U P A N C Y G R O U P S : B IN C I D E N T A L U S E S : *A L L I N C I D E N T A L U S E A R E A S P R O V I D E D W I T H A U T O M A T I C F I R E - EX T I N G U I S H I N G S Y S T E M S - R O O M S w / B 0 I L E R S O V E R 1 5 P S I A N D 1 0 H O R S E P O W E R ( S M O K E PA R T I T I O N ) - S T O R A G E R O O M > 1 0 0 SF . ( S M O K E P A R T I T I O N ) - W A S T E C O L L E C T I O N R O O M > 1 00 S F . ( S M O K E P A R T I T I O N ) OC C U P A N C Y S E P A R A T I O N S ( T A B L E 5 0 8 . 4 ) SE P A R A T E D B U I L D I N G O C C U P A N C I E S T O C O N F O R M W I T H S E C T I O N 50 8 . 4 O C C U P A N C Y S E P A R A T I O N A R E R E Q U I R E D - M A X . A R E A P E R M O S T R E S T R I C T I V E U S E OC C U P A N C Y L O A D S ( T A B L E 1 0 0 4 . 1 . 2 ) SE E O C C U P A N T S C H E D U L E BU S I N E S S A R E A S = 1 0 0 G R O S S ST O R A G E / M E C H A N I C A L = 3 0 0 G R O S S ME R C A N T I L E = 6 0 G R O S S AL L O W A B L E H E I G H T S / A R E A S T A B L E 5 0 4 . 3 , 5 0 4 . 4 & 5 0 6 . 2 TY P E V B C O N S T R U C T I O N GR O U P B : 9 , 0 0 0 / F L O O R , 3 S T O R I E S AL L O W A B L E A R E A : 2 7 , 0 0 0 / F L R AC T U A L H E I G H T : 4 6 ' - 1 0 " , 3 S T O R I E S AC T U A L A R E A : 6 , 4 3 0 M A I N F L O O R S F AC T U A L B U I L D I N G A R E A S : MA I N L E V E L : 6 , 4 3 0 S F SE C O N D L E V E L : 6 , 2 1 3 S F TH I R D L E V E L : 2 , 0 9 3 S F TY P E V B - F U L L Y S P R I N K L E D- N F P A 1 3 ( 9 0 3 . 3 . 1 . 1 ) FI R E R E S I S T I V E R E Q U I R E M E N T S ( T A B L E 6 0 1 A N D 6 0 2 ) ST R U C T U R A L F R A M E : 0 H R EX T E R I O R B E A R I N G W A L L : 0 H R IN T E R I O R B E A R I N G W A L L : 0 H R IN T E R I O R N O N - B E A R I N G W A L L S : 0 H R FL O O R C O N S T R U C T I O N : 0 H R RO O F C O N S T R U C T I O N : 0 H R EX T E R I O R N O N - B E A R I N G W A L L S B A S E D O N S E P A R A T I O N D I S T . 30 ' O R M O R E F I R E S E P A R A T I O N D I S T A N C E : 0 H R 10 ' T O 3 0 ' F I R E S E P A R A T I O N D I S T A N C E : 0 H R 5' T O 1 0 ' F I R E S E P A R A T I O N D I S T A N C E : 1 H R 5' O R L E S S F I R E S E P A R A T I O N D I S T A N C E : 1 H R 7' - 6 " M I N . C E I L I N G H E I G H T S ( 1 2 0 8 . 2 ) FL A S H I N G R E Q U I R E D T O P R E V E N T M O I S T U R E ( 1 4 0 5 . 4 ) RO O F F L A S H I N G R E Q U I R E D ( 1 5 0 3 . 2 , 1 5 0 7 . 5 . 7 ) FI R E S P R I N K L E R R E Q U I R E D T H R O U G H O U T ( N F P A 1 3 ) - S E C T I O N 9 0 3 . 3 . 1 . 1 FI R E P R O T E C T I O N S Y S T E M S : OCC. LOAD 61 58 17REQUIRED321321 1 1 1PROVIDED------------------MEANS OF EGRESS REQUIREMENTS COMMON PATH OF EGRESS TRAVEL (1014.3):-NOT TO EXCEED 100 FT - GROUP B (WITH SPRINKLER)TABLE 1015.1 - SPACES WITH ONE EXIT A, B, M = 49 OCC LOAD MAX S = 29 OCC LOAD MAX 2 EXITS REQUIRED (1021.2)7" MAX. RISE 11" MIN. TREAD - GROUP B STAIR LANDING & WIDTH 44" MIN. (1009.4)VERTICAL RISE MAX. 12' (1009.10)EXIT TRAVEL DISTANCE (TABLE 1016.2):WITH SPRINKLER SYSTEM GROUP B = 300 FT CORRIDORS (TABLE 1018.1):WITH SPRINKLERS GROUP B = 0 HR MINIMUM WIDTH OF 44" (TABLE 1018.2)DEAD ENDS 50 FT MAX (1018.4)VERTICAL EXIT ENCLOSURES (1022.2): 3 STORIES OR LESS = 1 HR FIRE BARRIER, NOT REQUIRED TO BE ENCLOSED ACCESSIBLE ROUTE:ELEVATOR REQUIRED (1104.4)INTERIOR ENVIRONMENT:NATURAL VENTILATION REQUIRED (1203.4)8% MIN. OF NATURAL LIGHT REQUIRED (1205.2) FI R E R A T E D C O N S T R U C T I O N EX T . W A L L S - F I R E S E P A R A T I O N D I ST A N C E ( F S D ) ( T A B L E 7 0 5 . 8 ) AR E A O F U N P R O T E C T E D O P E N I N G S I F F S D > 3 0 ' I S N O T R E Q ' D . IF F I R E S E P A R A T I O N D I S T A N C E ( F S D ) I S 3 ' T O < 5 ' , 1 5 % U N P R O T E C T E D OP E N I N G S IF F I R E S E P A R A T I O N D I S T A N C E ( F S D ) I S 5 ' T O < 1 0 ' , 2 5 % UN P R O T E C T E D O P E N I N G S IF F I R E S E P A R A T I O N D I S T A N C E ( F S D ) I S 1 0 ' T O < 1 5 ' , 4 5 % UN P R O T E C T E D O P E N I N G S PA R A P E T N O T R E Q U I R E D ( 7 0 5 . 1 1 ) : - E X C E P T I O N 1 : T H E W A L L I S N O T R E Q U I R E D T O B E F I R E - R E S I S T A N C E RA T E D I N A C C O R D A N C E W I T H T A B L E 6 0 2 B E C A U S E O F F I R E SE P A R A T I O N D I S T A N C E ( < 4 5 % ) . SH A F T E N C L O S U R E ( 7 1 3 . 4 ) CO N N E C T I N G 3 S T O R I E S O R L E S S : 1 H R CO N N E C T I N G 4 S T O R I E S O R M O R E : 2 H R FI R E P A R T I T I O N ( 7 1 0 . 4 ) CO N T I N U O U S T O U N D E R S I D E O F D E C K A B O V E O R R A T E D F L R / R O O F AS S E M B L Y C A N H A V E H O R I Z O N T A L O F F S E T S HO R I Z O N T A L A S S E M B L I E S ( 7 1 1 . 4 ) CO N T I N U O U S W I T H O U T O P E N I N G S / P E N E T R A T I O N S ( E X C E P T P E R 7 1 2 . 1 , 71 4 . 4 , 7 1 5 , 1 0 0 9 . 3 & 1 0 2 2 . 1 ) OP E N I N G R E Q U I R E M E N T S ( T A B L E 7 1 6 . 5 ) 1 H R F I R E B A R R I E R S ( S H A F T S , E X I T S ) : 1 H R O P E N I N G PR O V I D E P O R T A B L E F I R E E X T I N G U I S H E R S ( 9 0 6 . 1 ) 1 H R F I R E P A R T I T I O N ( D E M I S I N G W A L L S , E L E V . L O B B Y ) : 45 M I N . O P E N I N G 30 M I N F I R E P A R T I T I O N S ( C O R R I D O R S ) 20 M I N O P E N I N G BL O C K F R O N T A G E D E S I G N A T I O N : M I X E D ( T E C H N O L O G Y B L V D . W . ) ST O R E F R O N T B L O C K F R O N T A G E S WE A T H E R P R O T E C T I O N - A T L E A S T 5 ' A V E R A G E D E P T H A L O N G 6 0 % OF F A C A D E S , 8 ' - 1 5 ' V E R T I C A L C L E A R A N C E HE I G H T - M I N . 1 3 ' F L O O R T O C E I L I N G EN T R Y - F A C I N G S T R E E T TR A N S P A R E N C Y - A T L E A S T 6 0 % O F F A C A D E B E T W E E N 3 0 " A N D 1 0 ' SI D E W A L K = 1 2 ' M I N . LA N D S C A P E B L O C K F R O N T A G E S EX T R Y - F A C I N G S T R E E T TR A N S P A R E N C Y - 2 5 % B E T W E E N 4 ' - 8 ' WE A T H E R P R O T E C T I O N - 3 ' O V E R E N T R I E S SI D E W A L K S - 6 ' M I N . F O R A R T E R I A L S T R E E T S A N D P A R K S , 5 ' M I N . OT H E R ARCHITECTURE · PLANNING · DEVELOPMENT · INTERIORS 1425 WEST MAIN ST. · SUITE A · BOZEMAN, MONTANA · 59715 TELEPHONE: (406) 587-1204 · EMAIL: FHA@FHARCHITECTS.COM© 2020 FHA. It is unlawful to use any or all of these document without the expressed written consecnt of Faure Halvorsen Architects PC.A R C H I T E C T S F A U R E H A L V O R S E NDATE: 2020 G1.2JIM AND JULIE ROTHGEB, SITE V, BOZEMAN GATEWAY SITE V 2952 TECHNOLOGY BLVD. BOZEMAN, MT, 59715 GENERAL NOTESJOB NO: 19-999 04.21.2020