HomeMy WebLinkAboutStormwater Management 05-19-2020 DESIGN REPORT STORMWATER MANAGEMENT DELTA GAMMA SITE PLAN Prepared for: J&D Customs, Inc. 6550 Falcon Lane, Suite 4 Bozeman, MT 59718 Prepared by: C&H Engineering and Surveying, Inc. 1091 Stoneridge Drive, Bozeman, MT 59718 (406) 587-1115 Project Number: 200029 May 2020 INTRODUCTION The proposed Delta Gamma site plan is a parking lot development located on a 0.64-acre parcel in Section 13, Township 2 South, Range 5 East of P.M.M., Gallatin County, City of Bozeman. A combination of site grading, curb and gutter, curb cuts, swales, and retention ponds will be used to manage stormwater runoff on the site. Supporting stormwater calculations are attached to this report. A Drainage Area Map is included in Appendix A. Calculations for each individual drainage area (total area, weighted C factor, and time of concentration) are included in Appendix B. RETENTION POND DESIGN All ponds have been sized according to City of Bozeman Design Standards. Retention facilities are sized to capture the entire volume of the 10-year 2-hour storm event. The retention ponds are designed with an effective water depth of 1.5 feet, and maximum side slope of 4:1. Calculations used for sizing each pond can be found in Appendix C. STORM SEWER FACILITIES DESIGN Storm sewer facilities (curb cut and swale) were sized for the 25-yr storm using Manning’s Equation. The calculation assumed the cut and swale is at minimum slope (1%). The calculated peak flow contributing to the cut is 0.46 cfs. The 2’ wide curb cut has a minimum capacity of 5.50 cfs and can therefore adequately handle the runoff from this site. Curb cut calculations are included in Appendix D. Proposed Retention Pond The proposed retention pond is located just east of the proposed parking lot. It receives runoff from Drainage Area 1, totaling 0.39 acres. Runoff from Drainage Area 1 is conveyed via surface flow and gutters to the proposed curb cut. All curb cuts drain to swales which drain to the proposed pond. The required pond volume was calculated to be 572 cubic feet. The proposed volume of the pond is 705 cubic feet and has an effective depth of 1.5’. APPENDIX A DRAINAGE AREA MAP APPENDIX B DRAINAGE AREA CALCULATIONS DRAINAGE AREA #1 1. Calculate Area and Weighted C Factor Contributing Area C Area (ft 2)C * Area Hardscape 0.95 6830 6488 Landscape 0.20 9986 1997 Total 16816 8486 A = Area (acres) 0.3861 C = Weighted C Factor 0.50 2. Calculate Tc (Time to Concentration) Tc Overland Flow Tc = 1.87 (1.1-CCf)D1/2/S1/3 Storm S = Slope of Basin (%) 2.00% Return (yrs)Cf C = Rational Method Runoff Coefficient 0.35 2 to 10 1 Cf = Frequency Adjustment Factor 1.1 11 to 25 1.1 D = Length of Basin (ft) 95 26 to 50 1.2 51 to 100 1.25 Tc Overland Flow (minutes)10.3 Tc Gutter Flow Tc = L/V/60 V = (1.486/n)R2/3 S1/2 n = Mannings Coefficient 0.013 R = Hydraulic Radius A/P (ft) 0.13 (0.15' below top of curb) S = slope (%) 1.20% L = length of gutter (ft) 50 V = mean velocity (ft/s) 3.28 Tc Gutter Flow (minutes) =0.3 Tc Total = 10.6 (5 minute minimum) APPENDIX C RETENTION FACILTIES CALCULATIONS RETENTION POND # 1 REQUIRED VOLUME 1. Calculate Area and Weighted C Factor Contributing Area C Area (ft 2 )C * Area Hardscape 0.95 6830 6488 Landscape 0.20 9986 1997 Total 16816 8486 C=Weighted C Factor 0.50 2. Calculate Additional Required Volume Q = CIA V=7200Q C = Weighted C Factor 0.50 I = intensity (in/hr) 0.41 (10 yr, 2hr storm) A = Area (acres) 0.39 Q = runoff (cfs) 0.08 V = REQUIRED VOL (ft3)572 APPENDIX D STORM SEWER FACILITIES CALCULATIONS CURB CUT/SWALE REQUIRED CAPACITY 1. Calculate Area and Weighted C Factor (Post-Development) Contributing Area C Area (ft 2 )C * Area Hardscape 0.95 6830 6488 Landscape 0.20 9986 1997 Total 16816 8486 A = Area (acres) 0.3861 C = Weighted C Factor 0.50 2. Calculate Rainfall Intensity (Duration = Max Tc from Contributing Drainage Areas) i = 0.78x-0.64 (10-yr Storm, Fig. I-3, COB Design Standards) x = storm duration (hrs) 0.18 (DA #1) i = rainfall intensity (in./hr.) 2.37 3. Calculate 25-yr Pond Outflow Rate Q = CiA C = Rational Method Runoff Coefficient 0.50 (calculated above) i = rainfall intensity (in./hr.) 2.37 (calculated above) A = Area (acres) 0.39 (calculated above) Q = 25-yr Flow Rate (cfs) 0.46 MANNING'S EQUATION for OPEN CHANNEL FLOW Project: Delta Gamma Sorority Location: Bozeman, MT By: LRS Date: 5/5/2020 Chk By: Date: INPUT z (sideslope)= 0 Mannings Formula z (sideslope)= 0 w (btm width, ft)= 2 Q = (1.486/n)ARh2/3S1/2 d (depth, ft)= 0.5 R = A/P S (slope, ft/ft) 0.01 A = cross sectional area n low =0.013 P= wetted perimeter n high =0.013 S = slope of channel V = (1.49/n)Rh2/3S1/2 n = Manning's roughness coeffiQ = V x A Depth, ft Area, sf Wetted Perimete r, ft Hydraulic Radius, ft Velocity, fps Flow, cfs Velocity, fps Flow, cfs 0.5 1.00 3.00 0.33 5.50 5.50 5.50 5.50 T = 2.00 Dm = 0.500 Sc low = 0.0053 Sc high = 0.0053 sc =critical slope ft / ft T = top width of the stream .7 Sc 1.3 Sc .7 Sc 1.3 Sc dm =a/T = mean depth of flow 0.0037 0.0069 0.0037 0.0069 Low N High N d w z 11 z T Clear Data Entry Cells