Loading...
HomeMy WebLinkAbout004 C3.0 Civil Detail 5-19-20 24' f712C SPNLLT- 9" TqN GRnNUWt Flu 2" 5.4'(0.45') TOPSOIL •R 3/4"TO PER MARK A. INUS WE cruvu 1'SLOPE CHANDLoMPACTm sue-&5E � � j RaeeNvm Z No. 9518o S o / 0rna•,T e ® 9�f'�I DNEER PN��P CRUSHED GRAVEL BASE-3"MIN. 48" + TYPICAL ASPHALT CROSS-SECTION SUB-BASE COURSE MIN Sheet 3 of 3 C3.0 AS REQUIRED vnry nccEneEE SCALE:NTS PERMITaEaulRlo zx SLOPE Awnr MOM eulEOlNc COMPACTED SUBGRADE 2"&0/8'SQUARE GALVANIZED STEEL TUBE floo PrvE SET IN 18'OF CONCRETE(TYPJ C m E a'TNIDK PC' SIDevAuc 3/4" /SLOPR `�� N m e SLOPE g n m MIN.3.Of 1•CRUSHED AGGREGATE WE m Equessm- .5%f 'T n c coMPACTm sue-cRPDE SPILL CURB c a t DROP CURB NOTES; SIDEWALK 10R MAX 10R MA% SIDEWALK - J o 8 @1 1. SUBGRADE OR BASE COURSE COMPACTION SHALL CONFORM TO SECTION 02230(M.P.W.SPECS.1996 ED.) (n m NOTES: 2. CONTRACTION JOINTS SHALL BE PLACED AT 10'INTERVALS AND SHALL HAVE A MINIMUM DEPTH OF 3"AND MINIMUM r(lj: -Q 1. CONCRETE DEPTH FOR STD.SIDEWALKS SHALL BE 4" WIDTH OF b". GUTTER NOTE:TO BE MOUNTED AT A HEIGHT SO AS NOT [ o MIN. 3. EXPANSION JOINT MATERIAL SHALL BE PLACED AT ALL P.C.S,P.T.S,CURB RETURNS AND AT NOT MORE THAN 300' TO BE OBSCURED BY A VEHICLE PARKED IN THE !D p` INTERVALS.THE EXPANSION MATERIAL SHALL EXTEND THROUGH THE FULL DEPTH OF THE CURB AND GUTTER. SPACE. 2. SIDEWALKS SHALL SLOPE AWAY FROM STRUCTURES AND DETACHABLE WARNING SURFACE Ol m @ BUILDINGS AT 2%. 3. NO CURB AND GUTTER SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY THE CITY ENGINEER OR HIS (24"x WIDTH OF CURB RAMP) 3. CONCRETE SHALL BE 4,000 PSI®28 DAYS. REPRESENTATIVE. o '� 6.-.c 4. CONCRETE SHALL BE CLASS M-4000. pp 4. CONTRACTION JOINTS SHALL BE PLACED AT 5' 5. CRUSHED GRAVEL BASE SHALL MEET THE REQUIREMENTS OF SECTION 02235(M.P.W.SPECS.,2003 ED.)FOR CURB INTERVALS,EXPANSION JOINTS AT 20'INTERVALS. 3 AND GUTTER EXPANSION PROJECTS,WASHED ROCK MAY BE USED FOR THE GRAVEL BASE. z SIDEWALK CROSS-SECTION 3 CONCRETE CURB & GUTTER 4 HANDICAPPED ACCESSIBLE RAMP 5 H.C. PARKING SIGN c a C3.0 SCALE;NTS C3.0 SCALE:NTS C.O.B.STD.DWG.NO.02528-1 C3.0 SCALE;NTS C3.0 SCALE:NTS 8 s o y 4 3' 4 EXISTING GRADE 8 EXISTING GRADE ,� 4 1r- DEPTH PER CIVIL PLAN MAINTAIN PROPER SE SETBACK- _ SETBACK PER ZONING r " TYPICAL RETENTION POND SECTION ZONINGTONS I rl COMPACTED TOPSOIL C3 0 �5'TRANSRION SECTION FROM W r SCALE:1'=5' EXISTING CURB TO DROP CURB: a -L74 4H:1V MAX EXPANSION JOINTS COMPLETELY AROUND SIDEWALK SECTION 12"6z18"DEEP HOLE MAX.THROAT WIDTH r` FILLED WITH CONCRETE FLOW DEPTH 35'COMMERCIAL ------------ 40'INDUSTRIAL CURB 1,APRON POURED MONOLITHIC PROVIDE 6"COMPACTED UNLESS OTHERWISE APPROVED TOPSOIL TO FLOW DEPTH 2.50' CONTRACTION JOINT EXPANSION JOINTS AT CURB RETURNS 6 SIGN POST SETTING DETAIL 6 SWALE CROSS SECTION DETAIL C3.0 SSE:NTS C3.0 SCALE:NTS SIDEWALK CONTRACTION JOINTS I C3.0 DSCALE:ETAISL NOT USED BACK OF CURB SPACED AT 5'INTERVALS-MIN. FLOW LINE DEPTH 1'. EXPANSION JOINTS TO BE PLACED AT 25' EDGE OF GUTTER INTERVALS. & VARIABLE CONTRACTION JOINTS TO BE SPACED (5.5'TYP.) AT 10'INTERVALS IN CURB&GUTTER EXPANSION JOINT MATERIAL SHALL BE 1/2"THICK PRE-FORMED BITUMINOUS TREATED FIBERBOARD FILLER. ALL CURB REPLACEMENT SHALL BE DONE WITH INTEGRAL CURB AND GUTTER UNLESS OTHERWISE APPROVED. GRADE ESTABLISHED AS 1/4"RISE PER FOOT FROM TOP OF ADJACENT FULL HEIGHT CURB R 7TING SIDEWALK GRADE SIDEWALK DRIVEWAY APRON 1' •5'TYP. 5.5'TYP. VARIES) w 1/4'PER FOOT SLOPE STREET SURFACEo /A GA 0 3"WASHED ROCK 1�1 MIN.6"THICK CURB&CUTTER 5 M-4000 CONCRETE "OR MATCH EXISTING OR REQUIRED SIDEWALK WIDTH V ,Q DETAIL NOT USED „ DETAIL NOT USED ,2 NON-RESIDENTIAL APPROACH DETAIL NOT USED„ C3.0 SCALE:NTS C3.0 SCALE:NTS C3.0 SCALE:NTS C.O.B.STD.DWG.NO.02529-12 C3.0 SCALE:NTS A °Ou 20'-0" 0' Issue Date:5/22/2020 30 CUBIC YARD DUMPSTER W/COVERED ROLL-OFF TOP 1a ,5 DETAIL NOT USED CIO ___)CONSTRUCTION DUMPSTER DETAIL sc F.NTS C3.0 SCALE:NTS #200029