HomeMy WebLinkAboutSht SP1.2 Second Floor Plan 01-21-20DW DW UP GENERAL FLOOR PLAN NOTES A B SEE A4.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. OF STRUCTURAL INSULATED PANEL, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) SHADING LEGEND 42" WALL HEIGHT SHEAR WALL, SEE STRUCTURAL FLOOR PLAN KEYED NOTES (SHEET A1.0, A1.1, A1.2 ONLY) WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 ELECTRICAL METER LOCATION, SEE ELECTRICAL DRAWINGS 5 GAS METER LOCATION 6 FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/4" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. A2.2 1 A2.1 2 A2.2 2 A2.1 1 2 A3.1 2 5 61 F E D B C A 3 4 1 A3.2 2 A3.2 1 A3.1 E1.0 1 E1.0 2 E1.1 1 E1.1 2 187 SF BEDROOM 213 150 SF VESTIBULE 201 91 SF MECH 202 33' - 0" 14' - 0" 12' - 4" 14' - 0" 11' - 4" 84' - 8" 69 ' - 0 " 23 ' - 1 0 " 10 ' - 0 " 11 ' - 6 " 16 ' - 1 " 7' - 7 " 73 SF MASTER BA 205 22 SF UNIT A1 LAUND 203 22 SF UNIT 202 LAUND 204 202 203 204 209B 209 210 213A 213 214 212 212A 211 210B 207 206 205 206A 208 208A 209A 210A 126 SF STAIR 200 11 ' - 1 " 9' - 6 " 2' - 6 " 10 ' - 9 " P2 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 W1 W1 P2 P2 W1 W1 P3 W1 W1 W1 P1 P1 P1 P2 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 5' - 11" 12' - 4" 15' - 2" 2' - 6" 4' - 0" 10' - 2" 4' - 2" 6' - 2" 1' - 6" 6' - 5" 11 ' - 1 " 2' - 9 " 3' - 3 " 6' - 0 " 4' - 9 " 6' - 0 " 8' - 9 1 / 2 " 2' - 8 1 / 2 " 4' - 5 " 7' - 6 " 4' - 2 " 1' - 8 " 4' - 1 0 1 / 2 " 7" 4' - 6 " 36' - 3 1/2" 37' - 0 1/2" 33 ' - 1 0 " 11 ' - 6 " 16 ' - 1 " 7' - 7 " 73' - 4" 6' - 6 5 / 8 " 4' - 1 1 3 / 8 " 195 SF MASTER BR 212 84 SF MASTER BA 211 616 SF KITCHEN/LIVING 210 64 SF BATH 214 187 SF MASTER BR 206 148 SF BEDROOM 208 64 SF BATH 207 614 SF KITCHEN/LIVING 209 201 227 224 223 222 221 220 205 225 226 202 203 204 208 207 206 211 212 213 214 217 218 219 215 210 5' - 2" 7' - 2" 5' - 0" 10' - 5 1/2" 2' - 2 1/2" 2' - 9 1/2" 9' - 11" 5' - 0" 4' - 6 1/2" 8' - 1 1/2" 5' - 4 1 / 2 " 5' - 2 1 / 2 " 3' - 0" 6' - 3" 12' - 9" 6' - 5" 7' - 6" 3' - 4 1/2" 4' - 1 1/2" 7' - 6" 6' - 5" 12' - 8 31/32" 6' - 3" 4 1/2" 4 1/2" 3' - 3" 7' - 0" 7' - 0" 2' - 9" 6' - 6" 6' - 6" 6' - 10" 7' - 2" 6' - 2" 6' - 2" 3' - 11 1/2" 5' - 3 1/2" 4' - 9" 4' - 1 1 1 / 2 " 5' - 4 " P2.1 1 1 1 11 4' - 6 " 5' - 0 " 4' - 2 " 7' - 6 " 10 ' - 4 " 5' - 7 " 5' - 5 " 5' - 4 " SP2.1 1 SP2.1 2 SP2.2 1 SP2.2 2 SP2.3 1 SP2.3 2 SP2.4 2 SP2.4 1 EXTERIOR COVERED PATIO EXTERIOR COVERED PATIO An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 2 1 : 0 3 P M FL A N D E R S M I L L CL U B H O U S E BO Z E M A N , M T 1958 SP1.2 SECOND FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SUBFLOOR 2 -SP