Sht SP1.1 Main Floor Plan 01-21-20
REF. DW UP GENERAL FLOOR PLAN NOTES A B SEE A4.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. OF STRUCTURAL INSULATED PANEL, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) SHADING LEGEND 42" WALL HEIGHT SHEAR WALL, SEE STRUCTURAL FLOOR PLAN KEYED NOTES (SHEET A1.0, A1.1, A1.2 ONLY) WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 ELECTRICAL METER LOCATION, SEE ELECTRICAL DRAWINGS 5 GAS METER LOCATION 6 FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/4" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. A2.2 1 A2.1 2 A2.2 2 A2.1 1 2 A3.1 2 5 61 F E D B C A 3 4 1 A3.2 2 A3.2 1 A3.1 E1.0 1 E1.0 2 E1.1 1 E1.1 2 62 SF BATH 111 946 SF GYM 113 67 SF LEASING 1 103 246 SF MAINTENANCE 109 66 SF BATH 108 95 SF LOCKERS 116 94 SF RECEPTION 102 108 SF DISPLAY 104 BR E A K F A S T B A R 1 1/2 HT STPACE KITCHENETTE BAR SEATING POOL TABLE 90 SF VESTIBULE 101 32 SF STORAGE 105 101 SF BUSINESS CENTER 106 FIREPLACE AND TV FIREPLACE AND TV 1270 SF CLUBHOUSE 110 60" AND/OR FROSTED GLASS WALL FR E E W E I G H T S MAT EL L I P T I C A L EL L I P T I C A L TR E A D M I L L TR E A D M I L L ST A T I O N A R Y B I K E ST A T I O N A R Y B I K E UNIVERSAL MACHINE BE N C H MIRROR ON THIS WALL BE N C H 62 SF BATH 112 63 SF BATH 115 121 SF VESTIBULE 114 72 SF STAIR 100 20' - 0" 13' - 0" 14' - 0" 12' - 4" 14' - 0" 11' - 4" 84' - 8" 69 ' - 0 " 23 ' - 1 0 " 10 ' - 0 " 11 ' - 6 " 16 ' - 1 " 7' - 7 " 6' - 0 " 5' - 0 " 5' - 1 1 " 5' - 1 1 " 1' - 0 " 4' - 0 " 6' - 0 " 4' - 3 " 2' - 3 " 2' - 3 1 / 4 " 2' - 8 3 / 4 " 4' - 5 " 7' - 6 " 4' - 2 " 3' - 8 " 3' - 1 1 " 69 ' - 0 " 4' - 1 1 3 / 4 " 3' - 0 " 4' - 6 " 4' - 6 " 4' - 6 " 7' - 4 " 1' - 6 1 / 2 " 8' - 0 " 5' - 1 1 1 / 2 " 6' - 0 " 7' - 6 " 4' - 5 " 4' - 2 " 3' - 8 " 3' - 1 1 " 101 101-A 100 118 110-A 113 115 114 116 112 111 110 109-A 108 105 109 EL L I P T I C A L 27' - 10" 3' - 2" 3' - 5" 1' - 0" 3' - 2" 3' - 5" 11" 17' - 2" 3' - 4 1/2" 4' - 7 1/2" 5' - 3" 2' - 7" 4' - 0 7/32" 3' - 9 9/32" 6' - 8 " 7' - 1 0 " 5 1 / 2 " 8 1 / 2 " 4' - 2 1 / 8 " 4' - 7 7 / 8 " 11' - 0" 4' - 2 21/32" 5' - 9 1/8" 4' - 7 1/2" 7' - 4 1/2" 2' - 6" W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 6' - 6 2 9 / 3 2 " 3' - 2" 3' - 5" 1' - 0" 10' - 6" 4' - 1 9/32" 4' - 7 1/2" P1 P1 P1 P2 P2 P1 P2 P2 W1 P2 P2 P2 P1 P1 P2 P1 P1 46 SF WATER ENTRANCE 119 P2 P1 LINE OF SOFFIT ABOVE 101 102 104 105 106 107 122 121 108 110 111 112 113 114 115 116 117 119 120 3' - 0" 8' - 3" 14' - 0" 3' - 9" 8' - 9" 7' - 6 " 4' - 2 " 3' - 3" 14' - 0" 2' - 9" 11 ' - 0 " 11 ' - 1 0 " 11 ' - 0 " 11 ' - 6 " 16 ' - 1 " 7' - 7 " 6' - 10" 7' - 2" 1' - 9" 4' - 5" 4' - 5" 1' - 9" 8' - 4 1/2" 5' - 7 1/2" 118 98 SF Room 118 47 SF Room 117 117 119 1 1 11 109 SP2.1 1 SP2.1 2 SP2.2 1 SP2.2 2 SP2.3 1 SP2.3 2 SP2.4 2 SP2.4 1 EXTERIOR COVERED PATIO EXTERIOR COVERED PATIO GROUND MOUNT CONDENSING UNIT An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 2 1 : 0 2 P M FL A N D E R S M I L L CL U B H O U S E BO Z E M A N , M T 1958 SP1.1 MAIN FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SUBFLOOR 1 -SP