HomeMy WebLinkAboutSht SP1.3 Third Floor Plan 01-27-203 B C 21 D E 1 A3.1 2 A3.1 A 5 A7.1 8' - 2" 8' - 2" 5' - 7 1 / 2 " 2' - 3 1 / 2 " 2' - 0 " 64' - 7" 11' - 8" 9' - 0" 11' - 7 1/2" 32' - 3 1/2" 5' - 10" 5' - 10" 4' - 6" 4' - 6" 5' - 10 1/2" 5' - 9" 5' - 9" 5' - 10 1/2" 9' - 0" 5' - 10" 5' - 10" 48 ' - 1 1 1 / 2 " 0" 22 ' - 5 " 12 ' - 7 " 2' - 3 1 / 2 " 11 ' - 8 " 2' - 1 1 1 / 2 " 19 ' - 5 1 / 2 " 6' - 9 " 5' - 1 0 " 4' - 3 1 / 2 " 64' - 7" 2' - 0" 11' - 11" 8' - 2" 10' - 2 1/2" 32' - 3 1/2" 4' - 8 1/2" 7' - 2 1/2" 6' - 0" 2' - 2" 20' - 5" 2' - 2" 6' - 0" 11' - 11" 2' - 0" 48 ' - 1 1 1 / 2 " 22 ' - 5 " 14 ' - 1 0 1 / 2 " 11 ' - 8 " 2' - 1 1 1 / 2 " 19 ' - 5 1 / 2 " 6' - 9 " 5' - 1 0 " 2' - 3 1 / 2 " 2' - 7 1 / 2 " 9' - 1 1 1 / 4 " KITCHEN A303 ENTRY A300 DINING A306 BEDROOM B312 ENTRY B300 BATH B310 KITCHEN B303 LIVING B304 LIVING A304 LAUNDRY / UTILITIES A302 LAUNDRY / UTILITIES B302 BEDROOM A312 M. BATH A309 BATH A310 M. BEDROOM A307 M. CLOSET B308 M. BEDROOM B307 DINING B306 A301 A311 A305 A307 A306 A3 1 0 A3 0 2 A312 A313 A3 0 0 B3 1 0 B3 0 0 B312 B313 B311 B305 B307 B306 B301 B3 0 2 300 301 302 303 304 305 306 307 308 2' - 0 1 3 / 1 6 " 11 2' - 0 2 3 / 3 2 " CLOSET A313 ST O R A G E A3 0 5 LI N E N A3 1 1 ST O R A G E B3 0 5 LI N E N B3 1 1 CLOSET B313 DW REF. DW REF. 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim P3 UNIT A3 UNIT B3 P2 P1 P2 P1 P1 P2 P1 P2 P1 P1 P2 P2 P1 P2 P2 P1 P2 P1 P1 P2 P1 W1 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 A8.4 3 A8.4 3 2 B3 0 9 B3 0 8 M. BATH B309 B3 0 8 B3 0 9 COVERED EXT. PATIO COVERED EXT.PATIO COVERED EXT. ENTRY COVERED EXT. ENTRY EXT. STAIR COVERED EXT. WALKWAY GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2, A1.3 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 SHADING LEGEND SHEAR WALL, SEE STRUCTURAL An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 8 : 2 8 P M FL A N D E R S M I L L 6- H O U S E H O L D BO Z E M A N , M T 1958 SP1.3 THIRD FLOOR PLAN SITE PLAN SUBMITTAL JAN. 27, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SUBFLOOR LEVEL 3 -SP