HomeMy WebLinkAboutSht SP1.2 Second Floor Plan 01-27-203 B C 21 D E 1 A3.1 2 A3.1 A 5 A7.1 2' - 3 1 / 2 " 2' - 0 " 64' - 7" 5' - 10" 5' - 10" 4' - 6" 4' - 6" 5' - 10 1/2" 11' - 6" 5' - 10 1/2" 4' - 6" 4' - 6" 5' - 10" 5' - 10" 48 ' - 1 1 1 / 2 " 2' - 1 1 1 / 2 " 19 ' - 5 1 / 2 " 6' - 9 " 5' - 1 0 " 2' - 3 1 / 2 " 4' - 3 1 / 2 " 64' - 7" 4' - 8 1/2" 7' - 2 1/2" 6' - 0" 2' - 2" 20' - 5" 2' - 2" 6' - 0" 11' - 11" 2' - 0" 48 ' - 1 1 1 / 2 " 22 ' - 5 " 14 ' - 1 0 1 / 2 " 11 ' - 8 " 2' - 1 1 " 19 ' - 6 " 6' - 9 " 5' - 1 0 " 2' - 3 1 / 2 " 2' - 7 1 / 2 " 9' - 1 1 1 / 4 " P3 W1 P2 A2 0 1 A2 0 0 A201 A212 A213 A2 1 0 A211 A205 A207 A206 202 201 200 W1 W1 W1 W1 W1 W1 B205 B211 B2 1 0 B212 B213 B207 B201 B2 0 0 B2 0 2 M. BEDROOM B207 M. CLOSET B208 DINING B206 LAUNDRY/ UTILITY B202 LIVING A204 M. BEDROOM A207 M. BATH A209 BATH A210 BEDROOM A212 LAUNDRY/ UTILITY A202 DINING A206 LIVING B204 KITCHEN A203 KITCHEN B203 ENTRY A200 ENRTY B200 BATH B210 B206 207 203 204 205 206 208 CL O S E T A2 0 1 LI N E N B2 1 1 ST O R A G E B2 0 5 LI N E N A2 1 1 CLOSET A213 ST O R A G E A2 0 5 CLOSET B213 CL O S E T B2 0 1 11 1 A8.1 Sim 32' - 3 1/2" 32' - 3 1/2" 22 ' - 5 " 14 ' - 1 0 1 / 2 " 11 ' - 8 " 32' - 3 1/2" 32' - 3 1/2" DW REF. DW REF. 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim P1 P2 P1 P2 P1 P2 P1 P1 P2 P2 P1 P2 P2 P2 P1 P1 P1 P2 P1 W1 W1 W1 W1 W1 UNIT A2 UNIT B2 BEDROOM B212 A8.4 3 A8.4 3 2 M. BATH B209 B2 0 8 B2 0 9 A2 0 8 A2 0 9 M. CLOSET A208 COVERED EXT. PATIO COVERED EXT.PATIO COVERED EXT. ENTRY COVERED EXT. ENTRY EXT. STAIR COVERED EXT. WALKWAY GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2, A1.3 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 SHADING LEGEND SHEAR WALL, SEE STRUCTURAL An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 8 : 2 8 P M FL A N D E R S M I L L 6- H O U S E H O L D BO Z E M A N , M T 1958 SP1.2 SECOND FLOOR PLAN SITE PLAN SUBMITTAL JAN. 27, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O.SUBFLOOR LEVEL 2 -SP