Loading...
HomeMy WebLinkAboutSht SP1.1 Main Floor Plan 01-27-20A2.2 1 A2.1 2 A2.1 A2.2 2 3 B C 21 D E 1 A E1.0 2 64' - 7" 32' - 3 1/2" 32' - 3 1/2" 32' - 3 1/2" 32' - 3 1/2" 48 ' - 1 1 1 / 2 " 37 ' - 3 1 / 2 " 11 ' - 8 " 64' - 7" 32' - 3 1/2" 32' - 3 1/2" 48 ' - 1 1 1 / 2 " 22 ' - 5 " 14 ' - 1 0 1 / 2 " 11 ' - 8 " 22 ' - 5 " 11 1 A8.1 Sim DW REF. DW REF. 1 A8.1 Sim 6 A8.1 Sim 6 A8.1 Sim 6 A8.1 Sim UNIT A1 UNIT B1 1' - 0" 1' - 0" 1' - 0" 1' - 0" M. BEDROOM A106 DINING A105 LIVING A104 LIVING B104 DINING B105 M. BEDROOM B106 M. BATH B107 BATH B109 BATH A109 BEDROOM A110 ENTRY A100 CLOSET A101 KITCHEN A103 KITCHEN B103 ENTRY B100 CLOSET B101 LAUNDRY/ UTILITY A102 LAUNDRY/ UTILITY B102 BEDROOM B110 2 103 102 A105 104 105 B105 106 107 108 E100 B101 B110 B111 A101 A110 A111 A106 100 101 B1 0 2 B1 0 0 B109 B108 A1 0 0 A1 0 2 B106 B107 CLOSET B111 CLOSET A111 W1 W1 W1 W1 W1 W1 W1 P2 P1 P2 P1 P1 P2 P2 W1 W1 W1 P1 P1 W1 W1 P2 P2 W1 W2 W2 P1 P1 P3 P1 P1 P1 P1 W1 W1 W1 W1 W1 P2 P2 P1 P2 P1 P1 W1 W1 3 3 3 3 33 3 3 WATER RM E100 4 A107 A1 0 8 M. CLOSET A107 M. BATH A108 M. CLOSET B108 11 ' - 3 " 10' - 9" 2' - 6 " 2' - 6 " 4' - 0 " 2' - 6" 5 P1 P1 P2 SP2.1 2 SP2.1 1 SP2.2 1 SP2.2 2 SP2.3 2 SP2.3 1 SP2.4 1 SP2.4 2 COVERED EXT. PATIO COVERED EXT.PATIO COVERED EXT. ENTRY COVERED EXT. ENTRY EXT. STAIR GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2, A1.3 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 SHADING LEGEND SHEAR WALL, SEE STRUCTURAL An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 8 : 2 7 P M FL A N D E R S M I L L 6- H O U S E H O L D BO Z E M A N , M T 1958 SP1.1 MAIN FLOOR PLAN SITE PLAN SUBMITTAL JAN. 27, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SLAB LEVEL 1 -SP