HomeMy WebLinkAboutSht SP1.2 Second Floor Plan 01-21-20FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCTETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 ELECTRICAL METER LOCATION, SEE ELECTRICAL DRAWINGS 5 GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. STRUCTURAL INSULATED PANEL F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) SHADING LEGEND SHEAR WALL, SEE STRUCTURAL 3 A B 21 C D 1 A3.1 2 A3.1 4 A7.1 EX1.0 2 EX1.0 1 EX1.1 1 EX1.1 2 5' - 7 1 / 2 " 2' - 3 1 / 2 " 2' - 0 " 64' - 7" 11' - 8" 9' - 0" 11' - 7 1/2" 32' - 3 1/2" 5' - 10" 5' - 10" 4' - 6" 4' - 6" 5' - 10" 5' - 9 1/2" 5' - 9 1/2" 5' - 10" 4' - 6" 4' - 6" 5' - 10" 5' - 10" 48 ' - 1 1 1 / 2 " 0" 20 ' - 3 1 / 2 " 2' - 1 1 / 2 " 12 ' - 7 " 2' - 3 1 / 2 " 11 ' - 8 " 4' - 2 1 / 2 " 18 ' - 2 1 / 2 " 7' - 3 " 5' - 4 " 7' - 1 1 " 4' - 3 1 / 2 " 64' - 7" 2' - 0" 11' - 11" 8' - 2" 10' - 2 1/2" 32' - 3 1/2" 5' - 6" 5' - 11 1/2" 6' - 0" 2' - 2" 48 ' - 1 1 1 / 2 " 20 ' - 3 1 / 2 " 17 ' - 0 " 11 ' - 8 " 4' - 2 1 / 2 " 16 ' - 1 " 2' - 1 1 / 2 " 7' - 3 " 5' - 4 " 2' - 7 1 / 2 " 9' - 1 1 1 / 4 " P3 W1 UNIT B2 UNIT A2 P2 A2 1 2 A2 0 0 A201 A202 A203 A2 0 9 A210 A208 A206 A207 202 200 B204 B2 0 9 B210 B205 B211 B212 B2 0 0 B2 0 1 B203 2' - 2" 6' - 0" 11' - 11" 2' - 0" W1 W1 W1 W1 W1 W1 W1 203 201 204 205 206 207 208 BEDROOM A202 CLOSET A203 M. BATH A204 BATHROOM A209 MASTER BEDROOM A206 LIVING / DINING A207 KITCHEN A211 ENTRY/HALL A200 CL O S E T A2 0 1 UTILITIES / LAUNDRY A212 UTILITIES / LAUNDRY B201 KITCHEN B202 LIVING / DINING B203 ENTRY/HALL B200 BEDROOM B211 CLOSET B210 M.CLOSET B206 MASTER BEDROOM B205 LINEN B208 CLOSET B204 BATHROOM B209 B208 CLOSET B212 CL O S E T A2 0 8 P2 P2 P2 LI N E N A2 1 0 1 1 DW REF. REF. DW 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim W1 W1 W1 P2 P2 P1 P2 P1 P1 P1 P2 P1 P2 P1 P1 W1 W1 W1 W1 A8.4 3 A8.4 4 2 M. CLOSET A205 A2 0 5 A2 0 4 B2 0 6 B2 0 7 M. BATH B207 SP2.4 1 SP2.3 1 SP2.4 2 SP2.3 2 COVERED EXT. PATIO COVERED EXT.PATIO COVERED EXT. ENTRY COVERED EXT. ENTRY EXT. STAIR COVERED EXT. WALKWAY An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 2 : 2 2 P M FL A N D E R S M I L L 4- H O U S E H O L D 2 -2 BO Z E M A N , M T 1958 SP1.2 SECOND FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O.SUBFLOOR LEVEL 2 -SP