HomeMy WebLinkAboutSht SP1.1 Main Floor Plan 01-21-20FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCTETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 ELECTRICAL METER LOCATION, SEE ELECTRICAL DRAWINGS 5 GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. STRUCTURAL INSULATED PANEL F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) SHADING LEGEND SHEAR WALL, SEE STRUCTURAL 3 A B 21 C D 1 A3.1 2 A3.1 4 A7.1 3 A7.1 EX1.0 2 EX1.0 1 EX1.1 1 EX1.1 2 64' - 7" 32' - 3 1/2" 32' - 3 1/2" 32' - 3 1/2" 32' - 3 1/2" 48 ' - 1 1 1 / 2 " 20 ' - 3 1 / 2 " 17 ' - 0 " 11 ' - 8 " 64' - 7" 32' - 3 1/2" 32' - 3 1/2" 48 ' - 1 1 1 / 2 " 20 ' - 3 1 / 2 " 17 ' - 0 " 11 ' - 8 " UNIT A1 UNIT B1 20 ' - 3 1 / 2 " 1 1 DW REF. REF. DW 6 A8.1 Sim 6 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim 6 A8.1 Sim 1' - 0 " 1' - 0" 1' - 0 " 2 MASTER BEDROOM A106 M. BATHROOM A104 BATHROOM A108 LIVING / DINING A107 LIVING / DINING B103 MASTER BEDROOM B104 BATHROOM B107 M. BATHROOM B106 CLOSET B108 BEDROOM B109 ENTRY/HALL B100 CLOSET B110 KITCHEN B102 KITCHEN A109 BEDROOM A102 CLOSET A103 ENTRY/HALL A100 CLOSET A101 UTILITIES / LAUNDRY A110 UTILITIES / LAUNDRY B101 WATER RM E100 A106 A103 A102 A101 A107 103 102 104 101 100 E100 108 B108 B109 B104 B103 106 107 105 B110 A1 0 0 A1 1 0 B1 0 0 B1 0 1 P3 W1 W1 W1 P1 P2 P2 P1 P1 W1 W1 P1 P1 P2 P2 W1 W2 W2 W1 W1 W1 P1 P1 P1 P1 W1 W1 W1 W1 W1 P1 W1 P1 3 3 33 3 3 3 3 3 4 Room A105 M.CLOSET B105 P1 P2 P2 2' - 6 " 4' - 0 " 2' - 6" P2 P2 P1 B216 A1 0 8 5 SP2.4 1 SP2.3 1 SP2.4 2 SP2.3 2 COVERED EXT. PATIO COVERED EXT.PATIO COVERED EXT. ENTRY COVERED EXT. ENTRY EXT. STAIR An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 2 : 2 1 P M FL A N D E R S M I L L 4- H O U S E H O L D 2 -2 BO Z E M A N , M T 1958 SP1.1 MAIN FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SLAB LEVEL 1 -SP