Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Sht SP1.2 Second Floor Plan 01-21-20
FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F SHADING LEGEND SHEAR WALL, SEE STRUCTURAL FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCTETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) 1 2 B B C C 3 E E 1 A3.1 2 A3.1 A A D 4 A7.1 E1.0 2 E1.0 1 E1.1 1 E1.1 2 2' - 0 " 5' - 4" 64' - 7" 2' - 0" 11' - 5 1/2" 9' - 1" 5' - 1" 1' - 2 3/4" 13' - 3 3/4" 3' - 4" 13' - 1" 6' - 0" 41 ' - 4 " 22 ' - 5 " 12 ' - 7 " 6' - 4 " 6' - 7 " 15 ' - 1 0 " 64' - 7" 11' - 8" 9' - 0" 11' - 8 1/2" 32' - 2 1/2" 5' - 10" 5' - 10" 4' - 6" 4' - 6" 5' - 11" 13' - 1" 10' - 6" 9' - 6" 4' - 11" 21 ' - 1 " 8' - 0 " 12 ' - 3 " 4' - 5 " 3' - 0 " 3' - 0 " 10 ' - 8 " 2' - 1 1 / 2 " 5' - 1 0 1 / 2 " 9' - 1 1 1 / 4 " P3 P2 A200 A2 0 2 A201 A204 A2 1 1 A210 A209 A207 202 A208 204 205 211 210 209 208 207 206 B202 B2 0 3 B204 B205 B209 B208 B2 0 0 B2 0 7 2' - 7 1 / 2 " 2' - 7 1 / 2 " UNIT B2 UNIT A2 W1 W1 W1 W1 200 201 203 ENTRY / HALL A200 CLOSET A201 UTILITIES / LAUNDRY A202 BEDROOM A203 A203 CLOSET A204 P2 M. BATHROOM A205 MASTER BEDROOM A207 LIVING / DINING A208 CLOSET A209 CLOSET A210 BATH A211 KITCHEN A212 KITCHEN B201 ENTRY / HALL B200 LIVING / DINING B202 P2 UTILITIES B206 CLOSET B207 B206 MASTER BEDROOM B203 CLOSET B204 CLOSET B205 CLOSET B208 BATH B209 3' - 9 1 / 2 " 1 1 5' - 11 1/2" 5' - 6" 6' - 3 1 / 2 " 6' - 3 1 / 2 " 1 A8.1 Sim 1 A8.1 Sim 1 A8.1 Sim DW REF. DW REF. 7 A8.1 Sim W1 W1 W1 W1 W1 W1 W1 W1 W1 P1 P1 P2 P1 P1 P2 P2 P1 P2 P1 W1 3' - 9 1 / 2 " A8.4 4 A8.4 3 2 M.CLOSET A206 A2 0 6 A2 0 5 SP2.3 1 SP2.3 2 SP2.4 1 SP2.4 2 COVERED EXT.PATIO COVERED EXT. ENTRY EXT. STAIR COVERED EXT.PATIO An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 0 : 5 4 P M FL A N D E R S M I L L 4- H O U S E H O L D 2 -1 BO Z E M A N , M T 1958 SP1.2 SECOND FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O.SUBFLOOR LEVEL 2 -SP