Loading...
HomeMy WebLinkAboutSht SP1.1 Main Floor Plan 01-21-20FLOOR PLAN KEYED NOTES WASHER OUTLET BOX, SEE PLUMBING. NO WATER SUPPLY LINES TO BE LOCATED ON EXTERIOR WALLS DUE TO FREEZING CONCERN. 1 (SHEET A1.1, A1.2 ONLY) OUTLINE OF ROOF ABOVE 2 DOWNSPOUT AND SPLASHBLOCK 3 RADON MITIGATION RISER. PROVIDE OUTLET FOR BOOSTER FAN @ EACH LEVEL 4 GENERAL FLOOR PLAN NOTES A B SEE A3.0 FOR PARTITIONS & ASSEMBLIES. DIMENSIONS ARE TO F.O. STUD, F.O. CONCRETE, OR CENTERLINE OF COLUMN. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS, WHERE NO DIMENSION IS PROVIDED CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FRAMING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALL ADEQUATE BLOCKING FOR ALL OWNER AND CONTRACTOR SUPPLIED EQUIPMENT. ALL MATERIAL AND FINISHES ARE TO BE AS SPECIFIED, OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS SHOWING ANY CHANGES TO PLANS AND DIMENSIONING. C D E F SHADING LEGEND SHEAR WALL, SEE STRUCTURAL FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10 FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8). WINDOWS IDENTIFIED AS 'EGRESS' SHALL HAVE MIN. CLEAR WIDTH OF 20", MIN. CLEAR HEIGHT OF 22", AND MIN. CLEAR AREA OF 5.7 SQ.FT., SILL HEIGHT TO BE 44" MAX ABOVE FLOOR. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS WITH PLUMBING FRAMING, CONTRACTOR TO VERIFY. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE. C D E F G H A B I CONSTRUCTION NOTES CONCTETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS, UNLESS NOTED OTHERWISE. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION - RESISTANT METAL MESH WITH 1/8" MIN. TO 1/16" MAX. OPENINGS. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR, IN LARGER THAN 9 SQ.FT., AND ANY GLAZING WHERE THE BOTTOM EDGES IS LESS THAN 18" ABOVE THE ADJACENT WALKING SURFACE SHALL BE SAFETY GLAZING. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE WITH IRC SECTION R316. INSULATION REQUIREMENTS CONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE IN ACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING MONTANA AMENDMENTS. APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS: CEILING: R-49 (UNCOMPRESSED R -38 ALLOWED AT EAVES) EXTERIOR WALL: R-21 (OR R -13 + R -5 CONTINUOUS INSULATION) BASEMENT WALL: R-19 (OR R -15 CONTIUNUOUS INSULATION) -SEE NOTE A SLAB PERIMETER: R-10 (OR R -15 IF HEATED SLAB) CRAWLSPACE WALL: R-19 (OR R -10 IF RIGID INSULATION) WINDOW / DOOR: U-0.33 (R -3) NOTE A: RES -CHECK ANALYSIS MAY ALLOW LOWER R -VALUE (R -10 MIN.) 1 2 B C 3 E 1 A3.1 2 A3.1 A E1.0 2 E1.0 1 E1.1 1 E1.1 2 64' - 7" 32' - 4 1/2" 7' - 4 1 / 2 " 41 ' - 4 " 35 ' - 0 " 6' - 4 " 64' - 7" 32' - 4 1/2" UNIT B1 UNIT A1 1 1 DW REF. DW REF. 1 A8.1 Sim 1 A8.1 Sim 6 A8.1 Sim 6 A8.1 Sim 6 A8.1 Sim 1' - 0 " 2 104 103 105 102 101 100 A100 A101 111 A108 B102 106 107 108 109 B104 B105 B108 A104 A103 A107 B1 0 3 B1 0 7 B1 0 0 E1 0 1 A1 0 2 A1 0 9 B106 P2 P2 P2 P1 P3 P1 P1 P2 P1 P1 P2 P1 P1 P2 P1 P1 P1 P2 P2 P1 P1 P1 P1 P1 W2 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 MASTER BEDROOM A107 LIVING / DINING A108 M. BATHROOM A105 BATHROOM A109 ENTRY / HALL A100 BEDROOM A103 CLOSET A104 KITCHEN A110 KITCHEN B101 ENTRY / HALL B100 UTILITIES B106 LIVING / DINING B102 MASTER BEDROOM B103 BATHROOM B108 UTILITIES / LAUNDRY A102 WATER RM E101 110 3 3 3 3 3 3 3 3 4 M. CLOSET A106 A1 0 5 A1 0 6 5 P1 P1 SP2.3 1 SP2.3 2 SP2.4 1 SP2.4 2 COVERED EXT.PATIO COVERED EXT. ENTRY EXT. STAIR COVERED EXT.PATIO An y u n a u t h o r i z e d r e p r o d u c t i o n o r u s e o f t h i s i n f o r m at i o n w i t h o u t t h e e x p r e s s e d w r i t t e n c o n s e n t o f B e c h tl e A r c h i t e c t s i s a v i o l a t i o n o f U . S . c o p y r i g h t l a w s. C o p y r i g h t © 2 0 2 0 B e c h t l e A r c h i t e c t s JOB: 45 1 5 V a l l e y C o m m o n s D r i v e # 2 0 1 Bo z e m a n , M T 5 9 7 1 8 40 6 . 5 8 5 . 4 1 6 1 p h 4 0 6 . 5 8 5 . 6 9 1 9 f a x N O T F O R C O N S T R U C T I O N B E C H T L E A R C H I T E C T S 1/ 2 0 / 2 0 2 0 2 : 0 0 : 5 4 P M FL A N D E R S M I L L 4- H O U S E H O L D 2 -1 BO Z E M A N , M T 1958 SP1.1 MAIN FLOOR PLAN SITE PLAN SUBMITTAL JAN. 21, 2020 REVISION SCHEDULE No. Description Date SCALE: 3/16" = 1'-0" 1 T.O. SLAB LEVEL 1 -SP