Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Sht LS4.2 - Irrigation Details 05-14-20
TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m CI T Y S U B M I T T A L S E T TS E TA O T N F O M CETIHCRA EPACSD N A L D E S N E C I L T Co r y B . Wh i t i n g # 1 0 6 2 9 A N A 05 - 1 4 - 2 0 -- - - BO Z E M A N - M O N T A N A NE X U S P O I N T - P H A S E 1 DE T A I L S IR R I G A T I O N LS 4.2 19-110 1-30-20 06-19-19 CBW JES PVC MAINLINE. COMPACTED BACKFILL WEED BARRIER FABRIC UNDER ROCK MULCH PER PLANS. 2" DEPTH OF SAND OR ROCK FREE SOIL ON TOP, BOTTOM AND SIDES OF MAINLINE LATERAL PVC LINE TOPSOIL, SEE LANDSCAPE PLAN AND DETAILS FOR DEPTHS FINISH GRADE ROCK OR WOOD MULCH IN PLANTER AREA, WOOD OR TURF IN LAWN AREA. SEE LANDSCAPE PLAN AND DETAILS FOR DEPTHS CONTROL WIRE. INSTALL BESIDE & BELOW TOP OF MAINLINE. INSTALL IN CONDUIT. TRENCH SECTION SCALE: NTS NOTES: 1.MAINLINE DEPTH SHALL BE 18" DEEP EXCEPT UNDER ASPHALT & CONCRETE PAVING AND AT P.O.C. SHALL BE MIN OF 24" & MAX OF 30". INSTALL ADDITIONAL FITTINGS & RESTRAINTS AS REQUIRED. 2.MAINLINE AND LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. 13 PVC CAP(TYP.) PAVING PAVING DITCH PVC CAP (TYPICAL) PAINT ENDS PINK AND LABEL AS 'IRR. SLEEVE' CLASS 200 SLEEVES OR GREEN ABS PIPE SIDE BY SIDE NOTE: 1.WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24-INCHES MINIMUM ABOVE FINISH GRADE. 2.ALL SLEEVES INSTALLED SHALL BE DUCT TAPED TO PREVENT DIRT OR OTHER DEBRIS ENTERING PIPE. ALL SLEEVES SHALL BE IDENTIFIED BY WOOD OR PVC STAKES AND BE SPRAY PAINTED WITH MARKING PAINT. REMOVE STAKES ONCE IRRIGATION SYSTEM IS COMPLETE. 18" MIN 24" MIN. TO FINISH GRADE 24" MIN. 30" MAX. SLEEVING SCALE: NTS15 SCH. 40 PVC COUPLER 30" COILED WIRE RECTANGULAR VALVE BOX MAIN SUPPLY LINE 18" DEEP MINIMUM SCH. 80 ST ELL SCH. 80 PVC "ACTION" UNION 3" DEPTH OF 34" MINUSWASHED GRAVEL LIMIT 2 VALVES PER VALVE BOX SCH. 40 PVC LATERAL LINE 12" DEEP MINIMUM SCH. 80 PVC "ACTION" UNION 12" MAXIMUM FROM CONCRETE WALK OR MOWSTRIP NOTE: 1.ADD PRE-PRINTED CHRISTY I.D. TAGS TO ALL NEW CONTROL VALVES AND CONTROL ZONE KITS. COORDINATE AND LABEL ALL CONTROL WIRE AT CONTROLLER WITH EACH VALVE IN THE FIELD, TYP. VALVE ASSEMBLY SCALE: NTS11 LATERAL LINE SCH.40 PVC LATERAL PIPE PER PLAN. SIZE PER PLAN. VALVE & FITTINGS, VALVE BOX PER PLAN. SCH. 80 TEE OR ELBOW. SCH 80 TEE WITH 1" OUTFLOW TO QUICK COUPLER PER PLAN, QUICK COUPLER IN 10" ROUND VALVE BOX. SCHEDULE 80 PVC, TYPICAL (LENGTH & SIZE AS REQ.) SCHEDULE 80 PVC TEE OR ELL, SIZE AS REQUIRED. LATERAL LINE LATERAL LINE NOTES: 1.ALL VALVE MANIFOLD PIPING AND FITTINGS TO BE SCH. 80 FITTINGS, UNLESS THERE IS A DRIP ZONE ALL BY ITSELF IN WHICH CASE THE PIPING SHALL BE SIZED PER THE FLOW OF THE DRIP ZONE. 2.MODIFY MANIFOLD AS NECESSARY DEPENDING ON HOW MANY VALVES ARE IN A CLUSTER. 3.MODIFY AS REQUIRED DEPENDING ON WHETHER THE VALVES ARE PARALLEL OR PERPENDICULAR TO MAINLINE. MAINLINE VALVE MANIFOLD SCALE: NTS12 3" 12 " FINISH GRADE Techline COMBINATION TEE MODEL TL075FTEE Techline TUBING 3/4" MIN.TRIPLE SWING JOINT LENGTH AS REQUIRED PVC TEE (SxSxT) OR 90° (SXT) SCH. 40 PVC PIPING NOTE: ·EACH CONNECTION IS CAPABLE OF MAX 10 GPM TECHLINE START CONNECTION (SWING JOINT RISER) SCALE: NTS17 1804 PRS PER LEGEND. LATERAL LINE WITH PVC TEE OR ELL. PVC STREET ELL OR MALE BARBED ELBOW. PVC FLEX HOSE OR SWING PIPE. PVC STREET ELL OR MALE BARBED ELBOW. FINISH GRADE. SET HEAD FLUSH WITH FINISH GRADE. LAWN POP-UP SPRAY HEAD EDGE OF PAVING . NOTE: 1.USE VAN OR HE VAN NOZZLES AS NEEDED TO KEEP WATER OFF SIDEWALK AND BUILDING. 2.LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. 3.INSTALL SAM FEATURE FOR SLOPED LAWN AREAS WHERE LOW HEAD DRAINAGE MAY OCCUR. 2-3" MIN. 12" POP-UP SPRAY SCALE: NTS10 VALVE BOX FINISH GRADE WEATHETRAK FLOW DECODER INSTALLATION SINGLE GREEN WIRE-OPTIONAL LED POWER- CAP WHEN NOTIN USE BRASS CLAMPS GREEN/ YELLOW STRIPED WIRES TO GROUNDING ROD 3M DBR/Y -6 SPLICE RED AND BLACK WIRES TO FLOW SENSOR EXPANSION COILS SOLENOID GRAVEL 5/8" DIA. X8 COPPER GROUND RODDRIVEN INTO GROUND WITH TOP OF ROD A MIN OF 6" BELOW GRADE. 50OLMS OR LESS. EXTENSION (LENGTH ASREQUIRED) WT2W-FD (FLOW DECODER) 2-WIRECOMMUNICATION PATH BLUE WIRES TO 2-WIRECOMMUNICATION PATH SCALE: NTS SCALE: NTS WEATHERTRAK 2-WIRE- 2 (TWO) 2-WIRE PATHS EXAMPLE 6,200 5,600 4,900 4,300 1 2 3 4 MAXIMUM WIRE LENGTH (FT) ASSUMING #162 WIRENUMBER OF ACTIVE VALVES ON 2-WIRE PATH WORST CASE 2-WIRE PATH LENGTH LIMITS WITH ALL DECODERS AT END OF 2-WIRE PATH 7.000 11.000 17.800 6.400 10.200 16.300 5.500 8.800 14.100 4.900 7.800 12.500 4.400 7.000 11.200 4.000 6.300 10.100 3.600 5.800 9.200 3.300 5.300 8.500 1 2 3 4 5 6 7 8 AWG 14AWG 16AWG 18 VALVES EVENLY DISTRIBUTED ALONG 2-WIRE (FT)NUMBER OF SIMULTANEOUS VALVES NOTES: 1. ALL WIRE SPLICING SHALL BE MADE WITH APPROVED CONNECTIONS. 2. MAKE ALL WIRE SPLICES IN VALVE BOXES. 3. LEAVE A MINIMUM OF 18" EXTRA WIRE AT ALL SPLICE POINTS. 4. MAXIMUM DISTANCE FROM DECODER TO VALVE = 150 FT. 5. MAXIMUM WIRE LENGTH = 10,200 FT. 6. WIRE LENGTHS INCLUDE MASTER VALVE AND #162 WIRE 1918 PLAN VIEW SECTION VIEW ALL SOLVENT WELD PLASTIC PIPING TO BE SNAKED IN TRENCH AS SHOWN. RUN WIRING BESIDE MAINLINE IN CONDUIT. NOTES: 1.SLEEVE BELOW ALL HARDSCAPE ELEMENTS (WITH CLASS 200 OR SCH. 40 OR SCH. 80 PER SPECS.) TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2.FOR PIPE AND WIRE BURIAL DEPTHS, SEE DETAIL 13 AND NOTES. 3.NO LINE VOLTAGE WIRING SHALL BE ALLOWED IN IRRIGATION TRENCHES. MAINLINE, LATERAL, AND WIRING IN THE SAME TRENCH MAINLINE PIPE LATERAL PIPE WIRING IN CONDUIT LATERAL LINE MAIN LINE WIRE IN CONDUIT PIPE, WIRE, AND TRENCH SCALE: NTS14 MANIFOLD PIPING, SIZE PER PLAN) MANIFOLD SEE DETAIL 12 NOTES: 1.MAXIMUM 2 VALVES PER VALVE BOX. 2.MODIFY AS REQUIRED DEPENDING ON WHETHER THE VALVES ARE PARALLEL OR PERPENDICULAR TO MAINLINE. 3.USE GREEN BOXES IN LAWN AREAS & TAN BOXES IN PLANTER AREAS. 4.BOXES WITH 2-VALVES SHALL BE A JUMBO SIZED BOX OR BIGGER PER LANDSCAPE ARCHITECTS DIRECTION. 5.VALVE SHALL BE ABLE TO BE REMOVED WITHOUT REMOVING VALVE BOX FOR MAINTENANCE. SEE DETAIL 20 FOR WIRING VALVE BOX WITH COVER: SIZE AS NECESSARY FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE. SEE LEGEND FOR MODEL PVC SCH 80 UNION (LINE SIZE) PVC SCH 80 NIPPLE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) REQUIRED IF RAINBIRD VALVE BOX IS NOT USED SCH 80 NIPPLE (2" LENGTH, HIDDEN) AND SCH 80 ELL. PVC SCH 80 UNION (PVC COUPLER NOT SHOWN) PVC LATERAL PIPE 3" MINIMUM DEPTH OF 3/4" MINUS WASHED GRAVEL PVC SCH 80 ELL 3" MIN. PRE-PRINTED CHRISTY VALVE ID TAG, TYP. A1 CONTROL VALVE SCALE: NTS NOTES: 1.THE PRS OPTION FOR CONTROL VALVES CAN BE DELETED IF THE STATIC PRESSURE AT THE VALVE IS LESS THAN 70PSI ON SPRAY ZONES, AND LESS THAN 75PSI ON 5000 SERIES ROTOR ZONES. 2.PRS OPTION IS REQUIRED FOR FALCON ZONES. 16 CONTROLLER SHOWN AS REFERENCE ONLY RAIN SENSOR 120 VAC POWER WIRE PATH #2 (IN CONDUIT) MASTER VALVE WIRE PATH #1 (IN CONDUIT) SEE DETAIL 18 FOR FLOW SENSOR (NOT SHOWN) WT2W-SVD-11 BLUE WIRES TO 2-WIRE COMMUNICATION PATH VALVE BOX WT2W-SVD-11 DECODER (BLUE CASE) EXTENSION (LENGTH AS REQUIRED) ELECTRIC VALVE AS REQUIRED. SEE DETAILS 2,11,12,16,27. SOLENOID EXPANSION COILS WHITE WIRES TO SOLENOID 3M DBR/Y -6 SPLICE FINISH GRADE WEATHERTRAK 2-WIRE DECODER AND VALVE SCALE: NTS 2-WIRE COMMUNICATION PATH NOTES: 1.WIRES MUST EXTEND 12" ABOVE VALVE BOX FOR SERVICE. 2.INSTALL BRICKS UNDER ALL VALVE BOXES, TYP. IF RAIN BIRD BOXES NOT USED. 3.WIRING TO BE INSTALLED IN CONDUIT. 20