Loading...
HomeMy WebLinkAboutSht LS4.1 - Irrigation Details 05-14-20TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m CI T Y S U B M I T T A L S E T TS E TA O T N F O M CETIHCRA EPACSD N A L D E S N E C I L T Co r y B . Wh i t i n g # 1 0 6 2 9 A N A 05 - 1 4 - 2 0 -- - - BO Z E M A N - M O N T A N A NE X U S P O I N T - P H A S E 1 DE T A I L S IR R I G A T I O N LS 4.1 19-110 1-30-20 06-19-19 CBW JES FINISH GRADE 1 CUBIC FOOT PEA GRAVEL SUMP VALVE BOX WITH COVER PVC BALL VALVE, SIZE PER LINE. 24" EXTRA LENGTH OF AR 1/2" OR 3/4" TUBING (AVAILABLE THRU GPH PRODUCTS) LINE COILED IN VALVE BOX. INSTALL MISC. FITTINGS AS REQUIRED. DRIP LINE FLUSH CAP SCALE: NTS BRICK (1 OF 4) REQUIRED IF RAINBIRD VALVE BOX IS NOT USED. NOTES: 1.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 2.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURER SPECIFICATIONS FROM MORE INFORMATION. 3.MAINTENANCE SHALL FLUSH LINES PERIODICALLY THROUGHOUT OPERATION SEASON. 3 NOTES: 1.EMITTER SPACING SHALL BE BASED ON PLANT SPACING. INSTALL ALL IRRIGATION USING THE COMPONENTS DESCRIBED ABOVE. 2.IRRIGATION EQUIPMENT SHALL BE COMPLETELY INSTALLED PRIOR TO PLANT LAYOUTS. 3.ADJUST IRRIGATION SPACING TO ACCOMMODATE FINAL PLANT LAYOUT. 4.1/2" PVC FLEX HOSE SHALL NOT EXCEED 4GPM, 3/4" PVC FLEX HOSE SHALL NOT EXCEED 8GPM AND 1" PVC FLEX HOSE SHALL NOT EXCEED 13GPM. 5.AT OWNERS DISCRETION, A LESS EXPENSIVE DRIP SYSTEM MAY BE INSTALLED. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS, SUBMITTAL CUT SHEETS AND POTENTIAL COST SAVINGS TO OWNER. HOWEVER, THE OWNER AND LANDSCAPE ARCHITECT MUST APPROVE ALL CHANGES IN MATERIALS AND CONSTRUCTION PRACTICES IF DIFFERENT FROM THE PLAN. 6.SMALL EVERGREEN TREES MAY NEED FEWER EMITTERS. CONSULT WITH THE LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLING IRRIGATION TO DETERMINE QUANTITY OF EMITTERS. 7.SEE IRRIGATION SHEET FOR DRIP EMITTER LEGEND. 8.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 9.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURER SPECIFICATIONS FROM MORE INFORMATION. PVC SCH 40, OR STICKY-STRIP PVC HOSE BY GPH. SIZE PER PLAN. PVC REDUCTION TEE AS NEEDED. SHRUB, PERENNIAL OR GRASS, TYP. SEE PLANTING PLAN AND EMITTER LEGEND. 12 TO 1" FLEXIBLE PVC HOSE MANUFACTURED BY GPH. CONTRACTOR SHALL SIZE PER NOTE #4. SPEC-CHECK PC CHECK VALVE EMITTER, TYP. SCHEDULE 40 CROSS. GLUE FITTING. SCHEDULE 40 TEE. GLUE FITTING. VARIES PER PLAN MAX. 5' GPH DRIP EMITTER PLAN VIEW SCALE: NTS ROOTBALL, TYP. FOR PLANTS REQUIRING ONLY ONE EMITTER, INSTALL THE EMITTER AT THE EDGE OF THE ROOTBALL. FOR PLANTS REQUIRING TWO EMITTERS, INSTALL ONE EMITTER AT THE EDGE OF THE ROOTBALL AND THE OTHER ON THE OPPOSITE SIDE OF THE ROOTBALL HALFWAY BETWEEN THE PLANT'S TRUNK AND IT'S EXPECTED MATURE CANOPY. FOR TREES SEE DETAIL 6. INSTALL 3 EMITTERS. INSTALL (2) 5GPH EMITTERS AT THE EDGE OF THE ROOTBALL ON OPPOSITE SIDES OF THE TREE AND THE OTHER 5PGH. EMITTER SPREAD OUT TO PROMOTE FUTURE ROOT GROWTH. EXPECTED MATURE CANOPY, TYP. 5 NOTE: 1.FOR LAYOUT OF MULTIPLE SHRUBS, CONTRACTOR SHALL USE TEE'S AS NECESSARY. 2.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 3.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURE SPECIFICATIONS FROM MORE INFORMATION. TOP SOIL 60" LONG MAXIMUM 14" LONG MINIMUM 1/2" FLEX TUBING DRIP EMITTER WITH FINISH GRADE PLANT OR TREE ROOTBALL 12" GLUED ON MALE ADAPTER FPT BASE PVC SCH. 40 TEE TO SECOND EMITTER MULCH PER PLANS THREADED PVC ADAPTER, SIZE AS REQUIRED. 2" 12 " FOR LAYOUT INFORMATION, SEE DETAIL: LS4.1/5 DRIP EMITTER SCALE: NTS PVC TEE, SIZE AS REQUIRED. FLEXIBLE PVC LATERAL LINE 4 NTSSCALE: NOTES: 1.LAYOUT SHOWN IS TYPICAL. ON SITE MODIFICATIONS WILL BE REQUIRED DUE TO VARYING SIZE OF PLANTER ISLANDS. CONSULT WITH LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLATION TO DETERMINE HOW MUCH DRIP NEEDS TO BE INSTALLED AND WHAT CONFIGURATION IS APPROPRIATE. 2.INSTALL NETAFIM DRIP TUBING UNDER WEED BARRIER FABRIC. USE THIS DETAIL FOR ALL TREES PLANTED IN COBBLE ROCK AREAS. CONTRACTOR SHALL BE CAREFUL NOT TO DAMAGE OR PINCH TUBING WHEN PLACING COBBLE ROCK AND BOULDERS. 3.TREES PLANTED IN LAWN AREAS WILL NOT BE WATERED BY DRIP BUT WILL BE WATERED BY THE LAWN SPRINKLERS. 4.THIS DETAIL IS FOR DESIGN INTENT ONLY AND IS NOT TO SCALE. CONTRACTOR MUST INSTALL DRIP LINE PER THIS DETAIL OUT TO THE DRIPLINE OF THE TREES MATURE SIZE. 5.FOR LINEAR PLANTERS WITH TREES, INSTALL NETAFIM IN STRAIGHT LINES RATHER THAN A CIRCULAR PATTERN AROUND THE TREE. 6.INSTALL A FLUSH VALVE (NOT SHOWN) AT THE END OF ALL DRIP LINES, PER PLAN. THREE (3) PC-05 DRIP EMITTER AT SURFACE, ATTACH DIRECTLY TO NETAFIM DRIPLINE . MATURE CANOPY OF DECIDUOUS OR EVERGREEN TREE. TRUNK OF TREE. NETAFIM TLCV26-1801 DRIP LINE TUBING WITH FITTINGS. START 12" OUT FROM TRUNK OF TREE THEN SPIRAL OUT FROM TRUNK TO TREES CANOPY ESTIMATED MATURE DIAMETER. ADJUST NETAFIM IN AND AROUND SHRUBS. SCH. 40 PVC LATERAL LINE PER PLAN. SIDEWALK OR OTHER HARDSCAPE MATERIAL (IF ANY), TYP. TREE DRIP WITH PARTIALPLANTING UNDER CANOPY6 RAINBIRD 44LRC QUICK COUPLER VALVE NOTES: 1.FLUSH ALL PIPING PRIOR TO INSTALLING VALVE. 2.WRAP ALL THREADS WITH TEFLON TAPE. 1.1/2 TO 2 WRAPS MAXIMUM. 3.COMPACT SOILS AROUND VALVE BOX TO 80% OF ORIGINAL DRY DENSITY. 4.INSTALL GEOFABRIC UNDER VALVE BOXES AND TAPE TO PIPE NIPPLES AND VALVE BOX. 5.BOX COLOR - GREEN IN TURF AND TAN IN PLANTER AREAS. 6.IRRIGATION SYSTEM TO BE BLOWN OUT WITH AIR COMPRESSOR THROUGH THE RPZ AND QUICK COUPLERS BEFORE FREEZING TEMPERATURES OCCUR, TYP. 7.SCH 80 PVC TEE OR ELL'S CAN BE USED ON ALL QUICK COUPLERS EXCEPT AT POINT OF CONNECTION (IF QUICK COUPLER(S) ARE INSTALLED AT THE POINT OF CONNECTION). ALL QUICK COUPLER FITTINGS AND NIPPLES AT P.O.C. QUICK COUPLER(S) TO BE GALVANIZED. VALVE BOX (SIZE AS REQUIRED) WITH EXTENSIONS IF NECESSARY INSTALL TOP OF VALVE BOX 1/2" ABOVE FINISH GRADE IN LAWN AREAS AND FLUSH WITH TOP OF MULCH IN PLANTERS. HEAVY DUTY GALVANIZED FASTENERS (2 REQUIRED) SCH. 80 NIPPLES 3/4" MIN GRAVEL BASE SCH. 80 STREET ELL MANIFOLD SCH. 80 TEE. SCH. 80 ELL AND STREET ELL 30" X 1" GALVANIZED ANGLE IRON STAKE QUICK COUPLER VALVE SCALE: NTS BRICK (1 OF 3). NOT REQUIRED IF RAINBIRD VALVE BOX IS USED. 7 NOTES: 1.INSTALL ROTORS 2"-3" AWAY FROM HARDSCAPE PAVING AND 12" AWAY FROM WALLS, BUILDINGS, FENCES OR OTHER STRUCTURES. 2.ALL ROTORS TO HAVE STAINLESS STEEL RISERS. 3.FOR ROTORS WITH FLOWS LESS THAN 8 GPM, STREET ELLS, TEES AND NIPPLES MAY BE 34" IN SIZE. 4.LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. SIDE VIEW TOP VIEW WITH STAINLESS STEEL RISERS. PVC LATERAL LINE (3) 1" MARLEX STREET ELLS ROTOR POP-UP SPRINKLER FINISH GRADE (3) 1" SCH 40 STREET ELLS COMPACTED SOIL 1" PVC SCHEDULE 80 NIPPLE 12" LONG MIN. NOT TO EXCEED 45 DEG. ANGLE. ROTOR HEAD SCALE: NTS9 PVC SCH 40 ELL ID TAG: PRE-PRINTED CHRISTY TOP OF MULCH FINISH GRADE PVC LATERALS PVC SCH 80 NIPPLE, CLOSE (2) BRICK (1 OF 4) NOT NEEDED IF RAINBIRD BOX IS USED. PVC SCH 80 TEE. SEE DETAIL 13-14 ON SHEET LS4.1 FOR MANIFOLD PIPING. INLET 1 1/2" FPT OUTLETS (2) 1" FPT PVC SCH 40 MALE ADAPTER (2) PVC MAINLINE. 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL. PVC SCH 80 1 1/2" NIPPLE (LENGTH AS REQUIRED) SEE DETAIL 20 FOR WIRING VALVE BOX WITH COVER: RAIN BIRD VB-JMB CONTROL ZONE KIT: RAIN BIRD XCZ-150-COM (INCLUDES 150PESB VALVE, PVC TEE, (2) QKCHK100 BASKET FILTERS AND (2) PSI M40X-100 PRESSURE REGULATORS. BASKET FILTER, TYP. PRESSURE REGULATOR, TYP. 14 1 / 4 " ± 1 / 2 " 22 1/2" ±1/2" 10 1 / 2 " ± 1 / 2 " 1-1/2" DRIP CONTROL ZONE KIT SCALE: NTS WATER SOURCE FROM WELL AND 2" LINE TO STOP AND WASTE VALVE. FIELD VERIFY EXACT LOCATION. 2" PVC MAINLINE TO VALVES 1 12"STOP AND WASTE VALVE. CONTRACTOR TO ENSURE WATERDRAINS PROPERLY TO PREVENT FREEZING. WELL 2" POINT OF CONNECTION SCALE: NTS 1.ADD BACKFLOW PREVENTION DEVICE IS REQUIRED BY LOCAL ORDINANCES. 2.INSTALL OPTIONAL GATE VALVE AFTER (STOP AND WASTE VALVE) IF DIRECTED BY OWNER. THIS WILL MAKE MAINTENANCE AND WINTERIZATION EASIER AND BETTER. 3.INSTALL FILTER PENDING WATER QUALITY TEST. 4.ALL P.O.C. PIPING TO BE COPPER OR BRASS/BRONZE TO 2' PAST QUICK COUPLER. INSTALL (GALV. PIPING IF DIRECTED BY OWNER/DEVELOPER) 1" RAINBIRD 44NP QUICK COUPLER 1 12" FLOW METER WITH REDUCER FITTINGS (WEATHERTRAK OR NETAFIM IF REQUESTED BY THE OWNER/DEVELOPER). INSTALL PER MANUFACTURERS SPECS. ADD 1 12" MASTER VALVE IFCOMBINATION MASTER VALVE/FLOW SENSOR IS NOT USED. GATE VALVE MANUAL DRAIN S&W FM MD GV QC CONTROL WIRING TO ELECTRIC CONTROL VALVES. SCALE: NTS WEATHERTRAK WALL MOUNT OUTDOOR NOTES: 1.MODIFY INSTALLATION OF THIS DETAIL AS NECESSARY FOR STANDARD INDOOR WEATHERTRAK CONTROLLERS TO BE LOCATED IN THE CONCESSIONS BUILDING AND AT THE FOOTBALL FIELD STORAGE ROOM. 2.INSTALL CONTROLLERS (INCLUDING GROUNDING) PER MANUFACTURERS SPECS. NOTES: 1.INSTALL ALL WIRING PER LOCAL CODE AND PER MANUFACTURE RECOMMENDED SPECS 2.MODIFY INSTALLATION IF OWNER ELECTS TO HAVE CONTROLLER INSTALLED INSIDE THE MAINTENANCE ROOM. 3.MODIFY INSTALLATION AS NECESSARY TO FIT MANUFACTURERS SPECS. AND ON-SITE CONDITIONS. 8 1 2 3/4" CONDUIT WITH #6 BARE COPPER WIRE TO GROUND ROD OR GROUND PLATE RAIN SENSOR PER SPECS- COORDINATE EXACT LOCATION AND ORIENTATION. LOCATE MIN. DISTANCE FROM CONTROLLER PER MANUFACTURE SPECS WEATHERTRAK 2-WIRE IRRIGATION CONTROLLER SECURED TO WALL WITH APPROPRIATE FASTENERS 120 VOLT ELECTRICAL POWER WIRES WITH GROUND WITHIN CONDUIT FOR AUTOMATIC CONTROLLER. SIZE AND INSTALL PER CODE SECURE CONDUIT TO WALL WITH 'C' OR 'U' CLAMP. SIZE AS REQUIRED 1", 1-1/2" AND 2" PVC CONDUIT- SIZE AS REQUIRED. CONTROL WIRING TO ELECTRIC CONTROL VALVES WEATHERTRAK AUTOMATIC IRRIGATION CONTROLLER SECURED TO WALL WITH APPROPRIATE FASTENERS WALL 120 VOLT ELECTRICAL POWER WIRES WITH GROUND WITHIN CONDUIT FOR AUTOMATIC CONTROLLER. SIZE AND INSTALL PER CODE. 1", 1-1/2" AND 2" PVC CONDUIT-SIZE AS REQUIRED. FINISH GRADE. PVC ELECTRICAL SWEEP ELL. (SIZE AS REQUIRED) CONTROL WIRING TO ELECTRIC CONTROL VALVES