Loading...
HomeMy WebLinkAboutSht LS3.1 - Planting & Hardscape 05-14-20TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m CI T Y S U B M I T T A L S E T TS E TA O T N F O M CETIHCRA EPACSD N A L D E S N E C I L T Co r y B . Wh i t i n g # 1 0 6 2 9 A N A 05 - 1 4 - 2 0 -- - - BO Z E M A N - M O N T A N A NE X U S P O I N T - P H A S E 1 HA R D S C A P E PL A N T I N G & LS 3.1 19-110 1-30-20 06-19-19 CBW JES ALL STAKES SHALL BE DRIVEN OUTSIDE THE EDGE OF THE ROOT BALL. ARBOR TIE, TYP.STAKES SHALL BE INSTALLED AT 60° ANGLES AROUND TREE AS SHOWN PLAN VIEW NOTES: IF TREE STAKING IS REQUIRED, THE FOLLOWING IS RECOMMENDED: 1.ALLOW FOR SOME TRUNK MOVEMENT. ATTACH ARBOR TIE TO TREE AND STAKE. 2.REMOVE ALL WRAPPING MATERIAL FROM ROOTBALL PRIOR TO PLANTING. 3.INSTALL THREE STAKES PER TREE, SPACED EVENLY AROUND THE TRUNK 4.REMOVE ALL STAKING AS SOON AS THE TREE IS STABLE. 5.CONTRACTOR SHALL PROVIDE TREE STAKING AS PART OF THE BASE BID. 6.CONTRACTOR TO REMOVE NURSERY TREE STAKE FROM ROOTBALL AT TIME OF PLANTING (TYP.). ARBOR TIE NAILED TO STAKE. ARBOR TIE. FOLD ENDS OF ARBOR TIE BACK. SECURE TO STAKE WITH 1" GALVANIZED ROOFING NAIL OR USE A KNOT. TREE STAKING SCALE: NTS 6'-8' STAKE, TYP. 2"Ø LODGE POLE STAKE, TYP. STAKE TO BE 6'-8' TALL TYP. 1 FINISHED GRADE PLACE ROOTBALL ON UNDISTURBED SOIL. NOTES: 1.SCARIFY SIDES OF PLANTER PIT PRIOR TO PLANTING TREE SO AS TO AVOID ANY GLAZING OR HARDENED AREAS THAT WILL BE DIFFICULT FOR ROOTS TO GROW THROUGH. 2.AMENDED SOIL TO BE USED IN ALL PLANTER PITS PER LANDSCAPE NOTES 3.REMOVE ALL ROCKS LARGER THAN 12" FROMPLANTER PIT AND HAUL ROCK OFF SITE IN LEGAL MANNER. 4.TREES SHALL BE PLANTED SO THAT SOIL HAS SUFFICIENT DRAINAGE. 5.CONTRACTOR SHALL PERFORM PLANTER PIT DRAINAGE TEST IN EACH PLANTING AREA. PITS THAT DRAIN LESS THAN 2"/HOUR SHALL BE ADJUSTED AS NEEDED TO DRAIN. 6.ROCK OR WOOD MULCH SHALL NOT TOUCH ANY PART OF THE TRUNK OF THE TREE, TYP. 7.ROOT FLARE OF TREE SHOULD BE PLACED 1" ABOVE EXISTING GRADE PER EACH 1" OF TREE CALIPER TO A MAXIMUM OF 2". 8.TREES IN BOULEVARDS TO BE PLANTED PER BOZEMAN CITY FORESTRY STANDARDS AT A MIN. ADJUST INSTALLATION AS NEEDED. OBTAIN PERMIT PRIOR TO PLANTING IN BOULEVARDS. ROCK MULCH OR WOOD MULCH PER PLANS. INSTALL FILTER FABRIC ONLY UNDER ROCK MULCH. BACKFILL PER SOIL NOTES/SPECS. WATER BASIN (ONLY REQUIRED IF REQUESTED BY LANDSCAPE ARCHITECT). DECIDUOUS TREE PLANTING SCALE: NTS 2X ROOT BALL WIDTH 2 FINISHED GRADE. PLACE ROOTBALL ON UNDISTURBED SOIL. BACKFILL PER SOIL NOTES/SPECS. WATER BASIN (ONLY REQUIRED IF REQUESTED BY LANDSCAPE ARCHITECT). ROCK MULCH OR WOOD MULCH, PER PLANS. INSTALL FILTER FABRIC ONLY UNDER ROCK MULCH. NOTES: 1.SCARIFY SIDES OF PLANTER PIT PRIOR TO PLANTING TREE SO AS TO AVOID ANY GLAZING OR HARDENED AREAS THAT WILL BE DIFFICULT FOR ROOTS TO GROW THROUGH. 2.AMENDED EXISTING SOIL PER LANDSCAPE NOTES TO BE USED IN ALL PLANTER PITS. 3.REMOVE ALL ROCKS LARGER THAN 12"FROM PLANTER PIT AND HAUL ROCK OFF SITE IN LEGAL MANNER. 4.TREES SHALL BE PLANTED SO THAT SOIL HAS SUFFICIENT DRAINAGE. 5.CONTRACTOR SHALL PERFORM PLANTER PIT DRAINAGE TEST IN EACH PLANTING AREA. PITS THAT DRAIN LESS THAN 2"/HOUR SHALL BE ADJUSTED AS NEEDED TO DRAIN. 6.MULCH SHALL NOT TOUCH ANY PART OF THE TRUNK OF THE TREE, TYP. 7.ROOT FLARE OF TREE SHOULD BE PLACED 1" ABOVE EXISTING GRADE PER EACH 1" OF TREE CALIPER TO A MAXIMUM OF 2". EVERGREEN PLANTING SCALE: NTS 2X ROOT BALL WIDTH 3 NOTES: 1.DO NOT INSTALL WEED FABRIC UNDER WOOD MULCH. 2.TREE WELL FOR SMALL FLOWERING TREES SHALL BE 4'-0" DIAMETER. 3.TREE WELL FOR LARGE SHADE TREES OR EVERGREENS SHALL BE 6'-0" DIAMETER UNLESS OTHERWISE NOTED. 4.AS TREES MATURE TREE WELL WILL NEED TO EXPAND. TOP OF ROOTBALL TREE WELL IN TURF AREA SCALE: NTS LAWN AREA PER PLAN. SHOVEL CUT EDGE.3" WOOD MULCH FOR TREES IN TURF AREAS. PULL BACK FROM TRUNK OF TREE SO MULCH DOES NOT TOUCH TRUNK. 4'-6' DIAMETER 4 PLACE ROOTBALL ON UNDISTURBED SOIL. PLACE TOP OF ROOTBALL FLUSH WITH FINISHED GRADE.WATER BASIN. USE WHEN NECESSARY PER LANDSCAPE ARCHITECTS REQUEST.ROCK OR MULCH PER PLANS. MULCH SHOULD NOT TOUCH ANY PART OF THE TRUNK OF THE SHRUB. FINISHED GRADE. BACKFILL PER SOIL NOTES AND SPECS. NOTES: 1.SCARIFY SIDES OF PLANTER PIT PRIOR TO PLANTING SHRUB/GRASS SO AS TO AVOID ANY GLAZING OR HARDENED AREAS THAT WILL BE DIFFICULT FOR ROOTS TO GROW THROUGH. 2.IMPORTED & AMENDED TOPSOIL PER LANDSCAPE NOTES TO BE USED IN ALL PLANTER PITS. 3.REMOVE ALL COMPACTED, CLAY OR ROCKY SOILS FROM PIT AND HAUL OFF SITE IN A LEGAL MANNER. 4.CONTRACTOR SHALL PERFORM PLANTER PIT DRAINAGE TEST IN EACH PLANTING AREA. PITS THAT DRAIN LESS THAN 2"/HOUR SHALL BE ADJUSTED AS NEEDED TO DRAIN. SHRUB & ORNAMENTAL GRASS PLANTING SCALE: NTS5 EXISTING SOIL ROCK OR WOOD MULCH PER PLAN. MULCH SHOULD NOT TOUCH ANY PART OF THE PERENNIAL. NOTES: 1.SCARIFY SIDES OF PLANTER PIT PRIOR TO PLANTING PERENNIALS SO AS TO AVOID ANY GLAZING OR HARDENED AREAS THAT WILL BE DIFFICULT FOR ROOTS TO GROW THROUGH. 2.REMOVE ALL COMPACTED, CLAY OR ROCKY SOILS FROM PIT AND HAUL OFF SITE IN LEGAL MANNER. 3.CONTRACTOR SHALL PERFORM PLANTER PIT DRAINAGE TEST IN EACH PLANTING AREA. PITS THAT DRAIN LESS THAN 2"/HOUR SHALL BE ADJUSTED AS NEEDED TO DRAIN. 12" DEPTH OF AMENDED SOIL PER SPECS. PERENNIAL PLANTING SCALE: NTS PLANT SPACING PER PLAN 6 NOTES: 1.ENSURE FINISH GRADE OF SOD IS 1" BELOW TOP OF CURB, WALK, OR EDGING. CONSULT WITH OWNER FOR PROPER DEPTH. 2.SEE SOD NOTES FOR ADDITIONAL INFORMATION ON SODDING AND SEEDING REQUIREMENTS 3.EDGING OF SOD TO BE SHOVEL CUT WHEN NOT NEXT TO CONCRETE SIDEWALK OR PATH. 4.TURF IS THE MOST HEALTHY AND WATER EFFICIENT WHEN MOWED AT A MIN. HEIGHT OF 212" - 3". CONCRETE CURB, SIDEWALK, PATH OR EDGING - SEE PLAN. SOD BASE OR ROOT AREA. AMENDED SOILS PER SPECS. CROSS RIP OR TILL SUBGRADE PER LANDSCAPE NOTE 19. AGGREGATE BASE. (NOT PAST OR UNDER EDGING). SUBGRADE COMPACTED TO 85%. SOD LAYING AND EDGE SCALE: NTS7 FINISH GRADE WHERE BOULDER RETAINS GRADE. BOULDER. FINISH GRADE. BOULDER, TYP. FINISH GRADE. GROUP BOULDERS SO AS TO APPEAR NATURAL. CUT FABRIC SO THAT BOULDER CAN REST ON TOP OF FABRIC. DO NOT REMOVE FABRIC FROM UNDER THE BOULDERS. BOULDER PLACEMENT SCALE: NTS NOTES: 1.PLACE ALL BOULDERS SUCH THAT 1/4 OF THE TOTAL MASS OF EACH BOULDER IS BELOW FINISH GRADE. 2.LANDSCAPE ARCHITECT SHALL APPROVE ALL BOULDER LOCATION AND ORIENTATION ON SITE. 9 NOTES: 1.ROCK SHALL BE SCREENED & DOUBLE WASHED AND BE FREE OF DEBRIS PRIOR TO INSTALLATION. IF ROCK SUPPLIER DOES NOT HAVE A WASH PLANT, THE LANDSCAPE CONTRACTOR SHALL STILL BE RESPONSIBLE FOR DOUBLE WASHING ALL ROCK AND BOULDERS PRIOR TO INSTALLATION. 2.INSTALL PRE-EMERGENT HERBICIDE TO THE TOP OF THE FABRIC AFTER INSTALLING PLANTS AND PRIOR TO INSTALLING MULCH. AFTER INSTALLATION OF THE MULCH THE CONTRACTOR SHALL EVENLY BROADCAST A SECOND APPLICATION OF SLOW-RELEASE PRE-EMERGENT HERBICIDE. APPLY PRE-EMERGENT HERBICIDE PER MANUFACTURERS RECOMMENDATIONS. 3.KEEP TOP OF ROCK 1"-112" BELOW ADJACENT WALKS AND CURBS. DO NOT ALLOW ROCKTO TOUCH THE TRUNK OF ANY PLANT. INSTALL ROCK AFTER INSTALLATION OF WEED BARRIER FABRIC AND PLANT MATERIAL. 4.CONTRACTOR TO ENSURE THAT TOP OF WEED BARRIER FABRIC IS FREE OF SOILS AND DEBRIS PRIOR TO PLACING ROCK. 5.SEE LANDSCAPE PLANS FOR ROCK TYPE AND DEPTH. WEED FABRIC NOTE: INSTALL 6" SOIL STAPLE IN WEED BARRIER FABRIC AT 5' O.C. TRIANGULAR SPACING. INSTALL 6" SOIL STAPLE AT 12" O.C. ALONG ALL WEED BARRIER FABRIC SEAMS. OVERLAP FABRIC MIN. OF 6" AT ALL SEAMS AS SHOWN BELOW. INSTALL SOIL STAPLE 6' O.C. ALONG EDGES & 2 AT EACH CORNER. FINISHED SURFACE OF ADJACENT CONCRETE SIDEWALK, CURB, OR OTHER HARDSCAPE ELEMENT PER PLAN. ROCK PER PLANS. SEE LEGEND ON PLANTING PLAN SHEETS FOR TYPES AND DEPTHS. FINISH GRADE PRIOR TO INSTALLING WEED BARRIER FABRIC AND ROCK. WEED BARRIER FABRIC. SOIL STAPLE AT 12" O.C. ALONG SEAM. BOULDER - SEE DETAIL #9 THIS SHEET. FINISH GRADE OF ROCK TO BE 1" BELOW TOP OF ADJACENT CONCRETE SIDEWALK, CURB OR OTHER HARDSCAPE ELEMENT PER PLAN. LANDSCAPE WEED BARRIER FABRIC. UNDISTURBED SOIL, EXCAVATE SOIL TO DEPTHS PER SOIL NOTES AND PER PLANS. ROCK AND WEED BARRIER FABRIC WITH BOULDER SCALE: NTS10 STEEL EDGING NTSSCALE: 1/2" x 6" STEEL EDGING TOP OF EDGING TO BE A MAXIMUM OF 1/2" ABOVE SURFACE MATERIAL. PLANTER BED MEDIA PER PLANS AND SPECS. COMPACT GRADES TO ADJACENT TO EDGE TO AVOID SETTLING. SPOT WELD. 24" #4 REBAR STAKE OR STAKES PROVIDED BY EDGING MANUFACTURE 8