Sht C1.2 - Site Plan - East Rev 2 05-19-20
KEY NOTES N N QA 6" CONCRETE CURB & GUTTER. oN SDR 26 PVC SANITARY SEWER SERVICES. SEE MECHANICAL PLAN FOR SERVICE LEGEND o SIZE AND CONTINUATION INTO BLDG. —— EXT'G PROPERTY LINE PROPOSED ADA RAMP WITH TACTILE SURFACE © 4" THICK CONCRETE WALKS WITH BROOM FINISH. CROSS SLOPE-2%(MAX). EXT'G ADJACENT PROPERTY LINE PROPOSED BOLLARD LIGHT EXT 0 0 INSTALL IRRIGATION SLEEVES AS REQUIRED. QO STOP SIGN. ADD STREET NAME SIGNAGE AT STREET INTERSECTIONS 'G EASEMENT © © _ __ PROPOSED LANDSCAPE RTNG WALL WITH STEPS 6" THICK REINFORCED COLORED & SCORED CONCRETE CROSSWALKS WITH m CONCRETE DRIVEWAY APPROACH. C.O.B. STD DETAIL 02529-12 __ - EXT'G SETBACK LINE BROOM FINISH. CROSS SLOPE-2%(MAX). ® "NO PARKING FIRE LANE" SIGN AND POST& CURB PAINTING. PAINTING CURB — EXT'G WETLAND BOUNDARY PROPOSED SANITARY SEWER MANHOLE V V — EXT'G WETLAND 30' & 50' SETBACK D4 PROPOSED WATER VALVE � o RED WITH 2 COATS AND STENCILED WITH "FIRE LANE NO PARKING" AT EACH o D 4" THICK THICKENED EDGE CONCRETE PATIO WITH TABLE, BENCHES AND S EXT'G SANITARY SEWER PROPOSED FIRE HYDRANT BARBEQUE GRILL. LOCATION. THOROUGHLY CLEAN CURB PRIOR TO PAINTING. Ss EXT'G SANITARY SEWER SERVICE ® PROPOSED CURB INLET OE CONCRETE RAMP. TEXTURE SURFACE & SLOPE TO MEET A.D.A. & CITY OF ® VISION CLEARANCE TRIANGLE W EXTG WATER MAIN BOZEMAN SPECS. o wS EXT'G WATER SERVICE PROPOSED STORM DRAIN AREA DRAIN S LANDSCAPED AREAS. SEE LANDSCAPE PLAN FOR DETAIL OPEN SPACE AREA SUMMARY- PHASE rrl EXYG PHONE LINE � PROPOSED STORM DRAIN MANHOLE 3 3 Q W4508 EXPO 8 - BIKE RACK, OR APPROVED EQUAL. ARCHITECT TO SPECIFY T FENCED DOG AGILITY PARK AREA - NORTH: w COLOR. O OAS EXT'G GAS LINE ® PROPOSED ELECTRICAL TRANSFORMER N REQUIRED: 10,800 SF nHP EXT"G OVERHEAD POWER LINE z " QU SNOW STORAGE AREAS PROVIDED: 15,169 SF (140.5%) © TRASH ENCLOSURE AND CONCRETE SLAB AND APRON. SEE ARCHITECURAL UP EXT'G BURIED POWER LINE FOR DESIGN AND DETAIL. PROPOSED COMMON OPEN SPACE AREA Q CONCRETE TRAIL PER C.O.B. PROST PLAN. AREA - EAST: w QH MAIL BOXES, SHELTER AND CONCRETE SLAB. SEE ARCHITECURAL FOR DESIGN REQUIRED: 7,200 SF AND DETAIL. PROVIDED: 14,422 SF (200.37) —— PROPOSED PROPERTY LINE w w CLASS II GRAVEL TRAIL PER C.O.B. STD DETAIL 02529-18 ————— PROPOSED EASEMENT — PROPOSED SNOW STORAGE AREA _ a a ® ---------- PROPOSED SETBACK X QI CARPORT. SEE ARCHITECURAL FOR DESIGN AND DETAIL LANDSCAPE BLOCK RETAINING WALL WITH STEPS AREA - PHASE I: - PROPOSED ROADWAY CENTERLINE N N QY CONCRETE STEPS WITH HANDRAIL REQUIRED: 18,000 SF S PROPOSED SANITARY SEWER MAIN I EXT G WETLANDS AREA AND BOUNDARY w w Qj STORM SEWER DRAINAGE/COLLECTION SYSTEM. SEE UTILITY PLAN AND PROVIDED: 29,591 SF (164.47) Ss PROPOSED SANITRAY SEWER SERVICE mr GRADING PLAN FOR DETAIL QZ PARK BENCHES (1 or 2) W PROPOSED WATER MAIN 0. N K 4" WIDE YELLOW STRIPING - TWO COATS. WS PROPOSED WATER SERVICE z ® DEAD END BARRICADE PER COB STD DTL 09810-2 FS PROPOSED FIRE SERVICE © BARRIER FREE PARKING STALL WITH A.D.A APPROVED SIGNAGE AND ® RELOCATED ARCH CULVERT. SEE 319TH DESIGN DWGS FOR DETAIL PROPOSED STORM SEWER PAVEMENT MARKINGS. PROPOSED CURB AND GUTTER PROPOSED Q DUCTILE IRON/COPPER FIRE AND COPPER WATER SERVICES. SEE MECHANICAL PROPOSED PIAV MAENT STRIPING SON rANq PLAN FOR SERVICE SIZE AND CONTINUATION INTO BLDG. UP PROPOSED UNDERGROUND POWER GHRIS G. OAS PROPOSED UNDERGROUND GAS BUDESKI TFI PROPOSED UNDERGROUND COMMUNICATION N.men RE 4•c SEE SHT C1.1 FOR NORTH AREA _ DRAWN BY: CGB —s= ---- --'-1---- - B - ---- rt�--- - - - ---- UNITS 1 � �Z PHASE PHASE I _\ I I REVIEWED BY: DAD Q u rp LINE/4" ; 111 I I w PROJECT ENGINEER:CGB ' SE E I :CGB w IIII w w w w w w w w�� \ y 1 N ,�� �n\ C'g �1�1r�� R Iuill V" A J w ��- �'V`. A �•� ��� S 19TH AVENUE SCALE R i E J A 5 STATE OF MONTANA 0 15' 30, 60' nit S � w B S .\ 1 I I I I D.O.T. ROADWAY � IIII B op�\� \ I I"-- 30' Ll—UP10 ---, 3 I D --------_----_- --------_----_-- ---- ------- -- -_- �S S �r--— --- -— B '� PHASE I 1 3 I 2088 ARNOLD � v�EBLDG G �� / Q v \ \ \ o I I I S 24-PLEX 2-BEDROOM UNITS I�+ Q PHASE I Ir J D i .O O \ \\ \ /� / P � � �`� � \ �� � .a � SEE SOUTH 19TH �°�Q- CID L HASE WIDENING DESIGN �J Q��p° P O - --- -- _ FOR PROPOSE>- D J O 3 B X r B X w B X N ; F : OU \ 0 / \ ♦ e"� -- -u------ -- - ----- I AY II1SPRo ROADWVEMIIVTs °�\E R ---- J I 3 0�\ Y� B-- -1--- Its ,OS \� D U E a B K �; ��, �y� w R ARNOLD STREET A I I T - s DB AS O A ————- A O K D G i - T TEL L SK 9 Z � ���TESE C�i. D o - � I o ,— II TEL Es Is s s Ss I e� �a I C S - N o R ' C I 0 E r- / w w wJ------------ G °L Jf - - \� / s ' S 89° Y B II I IIIII a Ic a 3 I;o'R�-,i' B S0'uOS I 1 __\_0K_ _ _K__GK_'r✓__ 1_4_F©_AS S _�_ K -I- K B 1K2 ;taS S CE p 3��� sb -E U B •�I-Y O� _ 1IIII ---- --, -(V---- ---- � " � ------- > PHASE -EW-D�IEGT■1IE I T B B LINE I iR- - ,� � gSo SDA_ __ ____ � jt C 3� V00 OF LAND ZONE 2�A E I SETBACK C 0 EXT'G STR EAM Is,� ° V - CHANNELR 2078 ETBACK0B 12 1 ER D E W BLDGH ZON yd��aekdi� eWHI-q. 0o�0�-a 24-PLEX �•(1 +��! ,WETLAND \rd \ S A 2 ETBACK \� I I I.,� ~ a E• o 2068 ARNOLD I Yy d \ 4Fz T E Qs � CLUB HOUSE B I i ©S�' � BEDROOM I PHASE \\II�� ✓.,� �� ,I PHASE I ° E K B © UNITS B LINE I WETLAND PO I -_ M 1 -J PHASE i i sETBACKI i DROP 0 C21 w \, u COMM. I CURB I I A Y O i q j AREA T E N --------- N - cn v a� \ i i a K B I I I I b F \ \ A 8 I I cn _ 4 PHASE \\ \\I B �II\ i -----I g G -- - --DROP CURB Q fO Z J PHASE II I I Ili I I{ II _ 00 LINE \� A\ k < — — --0 - - t ---- �uNE L s PARK SHEET \ NT g II IIII` 3 I A o I I I I C1 .2 I I PROPOSED 1.2 ACRE NEXUS POINT PUBLIC PARK IJ w " CONSTRUCTED WITH SITE PLAN 4 PHASEI �I B I PROJECT:18-127 j 0 I� a DATE:06-19-19 A