HomeMy WebLinkAboutA1.2 Proposed Code Plan 06-09-2020MEN'S
BUNKROOM
WOMEN'S
BUNKROOM
STAFF
DESK 1
STAFF
DESK 2
W.C. 1W.C. 2
60 beds
60 beds
MEN'S RESTOOM
WOMEN'S RESTROOM
FOYER
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
LAUNDRY
1
SITTING
ROOM
SI
D
E
W
A
L
K
SI
D
E
W
A
L
K
SI
D
E
W
A
L
K
SIDEWALK
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
MATERIALPRODUCTTRADENAMEMODELNUMBER
Utility 1
Utility 2
STORAGE LAUNDRY
2
Closet 1
Closet 2
Guest Storage 1
Guest Storage 2
1616
20
20
30
20
10,881 SF
R-1
120 ACTUAL OCC
259 SF
BUSINESS
2 OCC @ 1/200
MA
X
T
R
A
V
E
L
45
'
ACT
U
A
L
S
E
P
A
R
A
T
I
O
N
=
1
1
3
'
-
6
"
MA
X
T
R
A
V
E
L
86
'
MA
X
D
I
G
O
N
A
L
=
1
7
3
'
-
1
0
"
MIN
.
S
E
P
A
R
A
T
I
O
N
=
5
8
'
1 HOUR WALL REQ. FSD < 10'
Hand rails req'd both sides.
Max. 7" rise and 11" min. run for stair
MATERIALPRODUCTTRADENAMEMODELNUMBER
16Exit Load
Max. Diagonal
Actual Min. Separation
Max. Travel Path
1 Hour Fire Resistance
B Occupancy Group
2 Hour Fire Resistance NONE REQUIRED
CODE SUMMARY - 2018 IBC
R-1 Occupancy - 120 beds provided = 120 occupants
B Occucpancy 259 s.f. @ 1/150 = 2 occupants
Total Occupant LOad = 122
Construction Type VB - Max Area Allowed per Table 506.2 = 28,000 s.f. with sprinkler throughout the main story.
Actual Area = 11,140 s.f.
Per Code section 420 - Sprinkler is required throughout.
Fire Ratings per Table 601 = 0 for Type VB construction
Fire Ratings per Table 602 based on fire separation distance. 0-10 feet = 1 hour, Greater than 10 feet = 0
Fire separation per occupancy = 1 hour required @ R-1 to B occupancy
Exit Doors shall be equipped with panic hardware from egress side (interior) per 1010.1.9
Plumbing fixture count required per Table 2902.1 (and Montana annotated code)
Business occupancy - 1 per 25 M/F WC (and) 1 per 40 LAV (and) 1 per 100 DF (drinking fountain).
R-1 occupancy - 1 per 10 M/F WC (and) 1 per 10 LAV (and) 1 per 8 Shower/tub (and) 1 service sink
Plumbing Fixture count required per occupant load.
WC = 7 M and 7 F
LAV = 7 M and 7 F
Shower = 8 M and 8 F
Drinking Fountain = 1
Service Sink = 1
CODE PLAN LEGEND
A1.2
EGRESS CODE PLAN
04.30.2020
WH
E
A
T
D
R
I
V
E
E
M
E
R
G
E
N
C
Y
S
H
E
L
T
E
R
06.09.2020
C:\Users\jptho\OneDrive - ThomBagg Architects\ThomBagg2020\HRDC\AutoCAD\2015WheatDrive\HRDC_A1.2.dwg, A1.2, 6/9/2020 1:26:50 PM,
DWG To PDF.pc3, ARCH expand D (36.00 x 24.00 Inches), JeffreyPThompson406-556-1955
Updated underlying floor plan
or consistency