Loading...
HomeMy WebLinkAbout003 FIXTURES COUNT 5-24-20 Residential(2012 IRC)for Alteration and Additions City of Bozeman Water Service Calculation Worksheet Project Address: 1ko P Property Owner:_Lafr v QA�P r General Contractor: Rjc V 1e4 o l Ly5 a4n , Wo1 OS-v d1 (onSfic,_ticA io 1nC Permit Number: ?�PZ8- 000Z"13(30 Proposed Water Meter Size: 1 ',qc1 Standard Design Water Supply Fixture Units Appliances and Fixtures Units #of EXISTING Fixtures NEW Fixtures Total Bathtub or combo tub/shower(1/2-mvalve) 4.0 X Bath Tub(3/4"fill valve) 10.0 X Shower(per head) 2.0 X +/- Z = Clothes washer 4.0 X Dishwasher 1.5 X Hose Bibb 2.5 X Additional Hose Bibb(each) 1.0 X Lavatory Sink 1.0 X Kitchen Sink 1.5 X Laundry Sink 1.5 X Water closet[toilet] (1.6 GPF) 2.5 X Bidet 1.0 X Urinal (flushometer valve) Table Values* Total Number of Fixture Units 3.5 Fixture Unit Tables for Determining Water Pipe&Meter Size Pressure Range-Over 60 PSI Circle the length in feet to the farthest fixture&applicable service,meter&branch sizes below based on the total number of fixture units detailed above. Maximum Allowable Length in feet Meter& Supply& 60' 80' 100, 150' 200' Service Branches Y411 a/" 20 20 19 17 14 %" 1" 39 39 36 33 28 1" 39 39 39 36 30 %" 1%" 39 39 39 39 39 1" 1'/<" 78 78 76 67 52 1%" 1'/<" 78 78 78 78 66 1" 1%"/2" 85 85 85 85 85 1'/:" 1%" 151 151 151 151 128 2" 1s 151 151 151 151 150 1'/:" 2" 370 370 340 318 272 2" 2" 370 370 370 370 368 If count is over 370 fixtures,water demand does not meet table 6.10.4 and has to be engineered by a registered Montana mechanical engineers design,signed and stamped. 03.12.19