Loading...
HomeMy WebLinkAboutA3-42-Bldg E-S2 2nd. Floor Plan_1-21-20 UNIT TYPE KEY BUILDING LEGEND FIRE EXTINGUISHERS INDICATESSLOPE F.P. FIBER CEMENT PANEL ALL'A'UNITS v ❑ TRUSSES 2%MAX P.G. PAINTED GYP.SHEA RING OX DOOR KEV PBOVECHAIR RAILAND 1 BEDROOM DESIGOION OF UNITS RE ER CEMENT PANEL BELOW DESIGNATEDAS RE:CORRIDOR DETAIL O WINDOW KEY ANSI TYPE'A' C.J. CONTROL JOINT ALL'B'UNITS A(REFER TO SITE PLAN) IFLOI CEILING& ® METER LOCATIONS INDICATES HVAC WW -2 BEDROOM -- CENTERLINE CONDENSING UNIT F.D.C. FIRE DEPARTMENT (REFER TO SITE PLAN&MEP) F.S.R.R. FIRE SPRINKLER 0 RADON PIPE RISER ROOM ALL'C'UNITS s� 1 HR.FIRE BARRIER WALL - 1'-0"RECESS F.F. FINISH FLOOR IIN CEILING B.F.F. BELOW FINISH FLOOR -3 BEDROOM II g LOCATION OF STAGGERED L--U RE:1]/A2-00 B.F.C. BROOM FINISH,NON - STUD WALLS SLIP SEALED CONCRETE GENERAL NOTES: •UNITS LABELED ANSI'A'TO MEET ANSI A11].1-2009 FOR TYPE A(10031 DWELLING UNIT REFER TO FHA AND ANSI SHEETS FOR ACCESSIBILITY REQUIREMENTS. •ALL FIRST FLOOR DOOR HARDWARE TO BE LEVER HANDLE. •CHANGES IN FLOORING SURFACE TO BE 1/4"MAX.,1/2"MAX.CARPET PILE THICKNESS. •THRESHOLD AT DOORWAYS TO BE 1/4"MAX.OR 1/2"W/45 DEGREE BEVEL. •MAXIMUM FORCE FOR PULLING OR PUSHING SHALL BE 5 LB/FT. BETWEEN16LW8 FOR A FORWARMECHANISMS OR SIDE APPROACH. MOUNTED •GENERAL CONTRACTOR TO INSURE CONTROL,EXPANSION JOINTS IN ARCHITECTURAL FINISH ARE COORDINATED WITH STRUCTURAL LOCATIONS.REFER TO MANUFACTURER FOR SPECIFIC REQUIREMENTS PERTAINING TO MATERIAL USED. •METER AND FSRR ARE LOCATED ON A BUILDING-BY-BUILDING BASIS, REFERENCE SITE PLAN FOR LOCATIONS. •BUILDINGS MAY FLIP ABOUT CENTER LINE OR ROTATE,REFER TO SITE PLAN FOR BUILDING LOCATION AND ORIENTATION. •UNIT PLANS MAYBE REVERSED OR ROTATED WITHIN BUILDING PLAN.REFER TO BUILDING PLAN 2 FOR UNIT LOCATION AND ORIENTATION. •WALL MOUNTED SERVICE EQUIPMENT AND SERVICE LINES TO BE PAINTED TO MATCH BUILDINGS. 4-5 •FIRE EXTINGUISHERS ARE TO BE A MINIMUM 2A 1 OB:C CLASSIFICATION AND SHALL COMPLY WITH NFPA 10 GUIDELINES.REFER TO PLANS FOR LOCATIONS.(REFERENCE DETAILS 17/A7-11,18/A7-11) •ALL FIRST FLOOR DWELLING UNITS ARE TO MEET FHA AND ANSI'B'REQUIREMENTS UNLESS NOTED OTHERWISE.REFER TO FHA AND ANSI SHEETS FOR MORE INFORMATION. 231'-1" 38'-0" 10'-0" 23'-8" 1 1/2" 38'-11" 10'-0" 38'-11" 1 1/2" 23%6" 10%0" 38%0" 13'-8" ❑ � BALCONY ALCONY a ° BALCONY BALCONY ° 14'-3" 42"GUARDRAIL - 1a-3'• ° BEDROOM BALCONY BALCONY BEDROOM BEDROOM BEDROOM - BEDROOM BEDROOM LIVING ROOM DRAI LIVING ROOM BEDROOM BEDROOM ING 2"GUARL LIVING ROOM CLOSET LIVING ROOM BEDROOM BEDROOM CLOSET ' - - LIVING ROOM LIVING ROOM Al-2(b) �----------� CLOSET I GLQBE Cl-2(a) Al-2(b) Q B3 b B3 b � Cl-2(a) ( ) CLOSET CLOSEfiO.M ( ) BATHROOM ATHROOM UP ❑ ❑ 42"GUARDRAIL ❑ -- ❑ ❑ - El 0 THRO________ ________________ BATHROOM - BATH nKITrFlEN _________________ ____________F-;_____, BATHR M ( i ___ ♦ ❑ ❑ATHROO a_______ ___ __�_CLOSETcUPCLOSETM �♦IFv O KITCHENBEDROOM O KITCHEN ' --- BEDROOM KITCHENKITCHEN KITCHEN CLOSET BA HROOM CLOSET qO UP CLOSET ! CLOSET ---- R BATHROO _ _ , , Nc ❑ ❑ ____________ __________ __________ _____________ _________ ❑ _____ _____ ________ ❑ '❑ M o BA HROOM ' d0 CLOSET CLOSET Op CLOSET CLOSET Ob '0' ATHR KITCHEN BEDROOM O KITCHEN �0 KITCHEN CDKITCHEN O KITCHEN O O BEDROOM B 00 KITCHEN DOWN CLOSET ♦/ i�I�' A OOM :- �I j�l l i♦� HROOi�;�_:, DOWN i�l _ -------- TIT❑ THRO ___ BATHROOMBATHROOM _________________ _- ❑ATHROO _____ _ _---- ___ -- CLOSET i ❑ CLOSET ❑I 2"GUARDRAIL ❑I, -❑ 2"GUARDRAIL ❑'' -- GUARDRAIL ------ " --------- ❑ ❑ 42" ❑ O - I' ----- B3(b) ! DLQBET II B3(b) CLOSE n7_2 a Al-2(b) BEDROOM LIVING ROOM A�L LIVING ROOM Cl-2(a) - CLOSET 111 2( ) BEDROOM Al-2(b) CLOSET LIVING ROOM BEDROOM BEDROOM LIVING ROOM - LIVING ROOM LIVING ROOM BEDROOM BEDROOM BEDROOM In BEDROOM BEDROOM - BALCONY BALCONY _ BEDROOM 14•4' BALCONY BALCONY 4 BALCONY BAITCQNY a 1z.-o" z-o 38'_0" 10'_0" 1 12" 38'_11" 101_0" 38'-11" 1 1/2" 23'-B" 10•_0" 38'_0" 231'-1" 1 4-SG 2BUILDING TYPE 'E-S2' SECOND FLOOR 05,014 SF.) SCALE:1/8"=1'-O" COPYRIGHT®HEDK Architects ALL RIGHTS RESERVED z ICON APARTMENT HOMES DATE SHEET NUMBER ° AT FERGUSON FARM - PHASE B 01-21 -20 F�3OC � SITE DEVELOPMENT Cl PLANS A3 42 of-u-zo ARCHITECTS ^ PROJrE�CT APARTMENTS IN BOZEMAN,MONTANA FOR 4202 BELTWAY DRIVE ADDISON,TX 75001 I 1 SC BUILDING'E-S2' BOZEMAN APARTMENTS GROUP PHASE II, LLC. jxL 214.520.B878 hedk.com FLOOR PLANS