Loading...
HomeMy WebLinkAboutA3-41-Bldg E-S2 1st. Floor Plan_1-21-20 UNIT TYPE KEY BUILDING LEGEND FIRE EXTINGUISHERS INDICATES SLOPE F.P. FIBER CEMENT PANEL ALL'A'UNITS v TRUSSES 2%MAX P.G. PAINTED GYP.SHEATHING X DOOR KEY ABOVECHAIq RAILAND SYMBOL INDICATES FIBER CEMENT PANEL BELOW 1 BEDROOM LOCATION OF UNIT DESIGNATEDAS RONROLJOITAIL O WINDOW KEY (REFERANSITYPEWSITE C.J. CONTROL JOINT ALL'B'UNITS INDICATES ES HVAC AN) FALLS),CEILING& ® METER LOCATIONS INDICATES HVAC W -2 BEDROOM —- CENTERLINE CONDENSING UNIT F.D.C. FIRE DEPARTMENT (REFER TO SITE PLAN&MEP) F.S.R.R. FIRE SPRINKLER o RADON PIPE RISER ROOM ALL'C'UNITS a� I HR.FIRE BARRIER WALL F 1'-0"RECESS F.F. FINISH FLOOR C N I -3BEDROOM >g CEILING B.F.F. BELOW FINISH FLOOR LOCATIONOFSTAGGERED L 17IA2-00 STUD WALLS B.F.C. BROOM FINISH,NON- SLIP SEALED CONCRETE GENERAL NOTES: •UNITS LABELED ANSI'A'TO MEET ANSI A117.1-2009 FOR TYPE A 1003 DWELLING UNIT REFER TO FHA AND ANSI SHEETS FOR ACCESSIBILITY REQUIRE EN S. •ALL FIRST FLOOR DOOR HARDWARE TO BE LEVER HANDLE. •CHANGES IN FLOORING SURFACE TO BE 1/4"MAX.,1/2"MAX.CARPET PILE THICKNESS. •THRESHOLD AT DOORWAYS TO BE 1/4"MAX.OR 1/2"W/45 DEGREE BEVEL. •MAXIMUM FORCE FOR PULLING OR PUSHING SHALL BE 5 LB/FT. BETWEENROL FOR A FORWARMECHANISMS OR SIDE APPROACH. MOUNTED •GENERAL CONTRACTOR TO INSURE CONTROUEXPANSION JOINTS IN ARCHITECTURAL FINISH ARE COORDINATED WITH STRUCTURAL LOCATIONS.REFER TO MANUFACTURER FOR SPECIFIC REQUIREMENTS PERTAINING TO MATERIAL USED. •METER AND FSRR ARE LOCATED ON A BUILDING-BY-BUILDING BASIS. REFERENCE SITE PLAN FOR LOCATIONS. •BUILDINGS MAY FLIP ABOUT CENTER LINE OR ROTATE,REFER TO SITE PLAN FOR BUILDING LOCATION AND ORIENTATION. •UNIT PLANS MAY BE REVERSED OR ROTATED WITHIN BUILDING PLAN.REFER TO BUILDING PLAN 2 FOR UNIT LOCATION AND ORIENTATION. 4-5 •WALL MOUNTED SERVICE EQUIPMENT AND SERVICE LINES TO BE PAINTED TO MATCH BUILDINGS. •FIRE EXTINGUISHERS ARE TO BE A MINIMUM 2A 1 OB:C CLASSIFICATION AND SHALL COMPLY WITH NFPA 10 GUIDELINES.REFER TO PLANS FOR LOCATIONS.(REFERENCE DETAILS 17/A711,18/A7-11) •ALL FIRST FLOOR DWELLING UNITS ARE TO MEET FHA AND ANSI'B'REQUIREMENTS UNLESS NOTED OTHERWISE.REFER TO FHA AND ANSI SHEETS FOR MORE INFORMATION. 231'-1" 38'-0" 10'-0" 23'-8" 1 1/2" 38'-11" 10'-0" 38'-11" 1 1/2" 23•-8" 10-0" '%, ❑ 11'-8" ❑ 714 12'-0"1; 13'-8" ° PATIO PATI ° 13'-8" § PATIO � - PATIO _ ❑ 14._3" 1W-3"T ❑ BEDROOM - PATIO PATIO rBEEDROOM G O D O BEDROOM BEDROOM BEDROOM LIVING ROOM I G O CLOSET LIVING ROOM BEDROOM - - BEDROOM CL S CLOSET C 1 11_l 11 gar(b) LIVING ROOM =--__-- LIVING ROOM 4 Al-1 gar(b)i 1. \U a B3(a) CLOSET B3(a) CLOSET - _ ETH=ROOM C S T ❑ \ '❑ ❑' THRO ------- -- BATHROOM ♦�I �BATHR M -_-�----- BATHROOM -' -" � O ATHROO ---------------- li 'a CLOSET i ', T O M 1 1�/♦I__' I I/♦I ♦I - O < O i C N BEDROOM ' i GT EI 10 KITCHEN KITCHEN O' KITCHEN O f n BATHROOM I ° I � CLOSET � � 00 CLOSET LOS � T O--�� c ❑ ,❑ KITCHEN ( ) - __ _ __________ __________ —_—_--__ � ___ N � -- i KXXI CLOSET i Op CLOSETCIO FSTT _ Q 1(I( KITCHEN KITCHEN Q TIRESTOP TIRESTOP TIRESTOP BATHROOM BATHROOM -__• •I�-" T ❑ TIRESTOP TIRESTOP __ IRESTOP TIRESTOP ❑ ❑ ❑j O = TIRESTOP 11%10" 11'-2" C1-garb) m Cl-gar(c)-FSRR B3(a) CLOSET DLDBET B3(a) Al-garb) 9 BEDROOM LIVING ROOM LIVING ROOM BEDROOM E GARAGE I GARAGES GARAGE2 GARAGEI C G A 2 GARAGE2 GARAGEI ASSIGNABLE GARAGE2 GARAGES DIRECTACCESS ASSIGNABLE ASSIGNABLE - IR T C S DIRECT ACCESS ASSIGNABLE - ASSIGNABLE N ASSIGNABLE BEDROOM BEDROOM - PATIO PATIO - v v v v v v 10'-0" 23-13" 1 1/2" 38'-11" 1U'-0" 38'-11" 1 1/2" 29•-8" 10._0" 38%0" 231'-1" 1 1 BUILDING TYPE B-ST FIRST FLOOR (15,014 SF.) SCALE:1/8"=1'-0" COPYRIGHT®HEDK Architects ALL RIGHTS RESERVED z ICON APARTMENT HOMES DATE SHEETNUMBER ° AT FERGUSON FARM - PHASE B 01-21 -20 F E 3 OC ClA R C H I T E C T S PROJECT A3-41 APARTMENTS IN BOZEMAN,MONTANA FOR 4202 BELTWAY DRIVE ADDISON,TX 75001 191 SC BUILDING'E-S2' BOZEMAN APARTMENTS GROUP PHASE II, LLC. 214.520.B878 hedk.com FLOOR PLANS