HomeMy WebLinkAboutA3-31-Bldg D 1st. Floor Plan_1-21-20 UNIT TYPE KEY BUILDING LEGEND
ALL'A'UNITS FIRE EXTINGUISHERS INDICATES SLOPE F.P. FIBER CEMENT PANEL
-1 BEDROOM 4 TRUSSES2%MAX
DOOR KEY
P.G. PAINED GYRSHEATHING
X ABOVE CHAIR RAIL AND
ALL'B'UNITS SYMBOL INDICATES FIBEVE CHAT AILANDELOW
LOCATION OF UNIT pE:COPPIDNTDETAIL
-2 BEDROOM O WINDOW KEY DESIGNATED AS
ANSI TYPE'A' C.J. C�FO�NTROLJOINT
ALL'C'UNITS (REFER TO SITE PLAN) (FLAOOR),CEILING&
® METER LOCATIONS INDICATES HVAC W
-3 BEDROOM CONDENSING UNIT F.D.C. FIRE DEPARTMENT
-- CENTERLINE (REFER TO SITE PLAN&MEP)
CONNECTION
o RADON PIPE F.S.R.R. RISER ROOM ER
effi 1 HR.FIRE BARRIER WALL F —�,'-C RECESS F.F. FINISH FLOOR
I I IN CEILING B.F.F. BELOW FINISH FLOOR
»� LOCATION OF STAGGERED L--JRE:17IA2-00 B.F.C. BROOM FINISH,NON- REVISIONS
STUDWALLS SUPSEALEDCONCRETE
GENERAL NOTES:
•UNITS LABELED ANSI'A'TO MEET ANSI A117.1-2009 FOR TYPE A(10031 DWELLING UNIT
REFER TO FHA AND ANSI SHEETS FOR ACCESSIBILITY REQUIREMENTS. - -
•ALL FIRST FLOOR DOOR HARDWARE TO BE LEVER HANDLE.
•CHANGES IN FLOORING SURFACE TO BE 1/4"MAX.,1/2"MAX.CARPET PILE THICKNESS.
•THRESHOLD AT DOORWAYS TO BE 1/4"MAX.OR 1/2"W/45 DEGREE BEVEL.
•MAXIMUM FORCE FOR PULLING OR PUSHING SHALL BE 5 LB/FT.
•ALL CONTROLS AND OPERATING MECHANISMS SHALL BE MOUNTED
BETWEEN 15"-48"FOR A FORWARD OR SIDE APPROACH.
COORDINATED WITHTSTRUCCTURALEOCATIONS REFERITTO JOINTS IN FOR SPECI FINISH ARE
REQUIREMENTS PERTAINING TO MATERIAL USED.
•METER AND FSRR ARE LOCATED ON A BUILDING-BY-BUILDING BASIS.
REFERENCE SITE PLAN FOR LOCATIONS.
•BUILDINGS MAY FLIP ABOUT CENTER LINE OR ROTATE,REFER TO SITE PLAN
FOR BUILDING LOCATION AND ORIENTATION.
•UNIT PLANS MAYBE REVERSED OR ROTATED WITHIN BUILDING PLAN.REFER TO BUILDING PLAN
FOR UNIT LOCATION AND ORIENTATION.
•WALL MOUNTED SERVICE EQUIPMENT AND SERVICE LINES TO BE PAINTED TO MATCH BUILDINGS.
•FIRE EXTINGUISHERS ARE TO BE A MINIMUM 2A 1 OB:C CLASSIFICATION AND SHALL COMPLY WITH
NFPA 10 GUIDELINES.REFER TO PLANS FOR LOCATIONS.(REFERENCE DETAILS 17/A7-11,18/A7-11)
•ALL FIRST FLOOR DWELLING UNITS ARE TO MEET FHA AND ANSI'B'REQUIREMENTS UNLESS NOTED
OTHERWISE.REFER TO FHA AND ANSI SHEETS FOR MORE INFORMATION. M
W
w U
J
Cw� J
G= W
Ow o¢
2 LL_
Z�
¢a
z� oZD
m-0
4.4
w<
�LL NC/)
50'-0 12• �f m z
L DO CWC
40'-6" 1[a. 34'-4" 1 /2" 34'-4" 1 /2" 40'-6" Q O Z G
^ LU
Q/���•�R/, a Q
a PATIO 9 PATIO e O w Lu
W
�n ❑ 21'3 ❑ ❑ 21'� ❑ _m / �LL I�
PATIO PATIO V 0
BATHROOM ffBATH m
❑ ❑ ABOVE TOUNIT ABOVE TO BEDROOM
BEDROOM UP UP BEDROOM
___________ LIVING ROOM LIVING ROOM TO UNIT LIVING ROOM ^ LIVING ROOM TO UNIT B1-Igar(a) ABOPVEA2 7gar(a) BEDROOM BEDROOM �[-1Qar/a) A�UP B1 10ar(a) Z
CLOSE CLOSET L 1 D \ C SET W
'
6WTCHEN
�____________LOSET I W a�7i�I� �CLOS /♦ FBEDROOM KITCHEN KITCHEN LUBATHROOMBATHROOM BATHROOM KITCHEN BATHROOM i u
__ O O ,
Lj
TIRESTOP TIRESTOP TIRESTOP TIRESTOPcc
!n F c
TIRESTOP TIRESTOP TIRESTOP LL U 2
IN ESTOP - W N
12%3" 11'-0" 11'-1" 16'-8" 11'-10" 11'-10" 16'-B" 11'-1" 11'-p" 12'-3" -
TIRESTOP R
TIRESTOP j
IF B1-gar(a) = 2
A2-gar(a) A2-gar(a) r I , 2°
GARAGE 1 GARAGE 2 GARAGE 3 N UP GARAGE 2 GARAGE 1 GARAGE 1 GARAGE 2 UP GARAGE 3 N a 1-g ASSIGNABLE
GARAGE 1 v J
_ _ TO UNIT TO UNIT GARAGE2E '
DIRECTACCESS ASSIGNABLE DIRECT ACCESS ABOVE DIRECT ACCESS DIRECT ACCESS DIRECTACCESS DIRECT ACCESS ABOVE DIRECT ACCESS DIRECT ACCESS m�
UP UP
TOUNIT TO)NIT < aN
ABOVE ABOVE
o DATE
❑ ❑ ❑ ❑
N 01 -21 -20
x
PROJECT
c�
19182
40'-6" 1 112" 34'-0' 1111 34'-4"
1 1/2" 40'-6"
150'-o 1rz" SHEET NUMBER
a`
A3-31
1 BUILDING'D'
1 BUILDING TYPE D' FIRST FLOOR BUILDING TYPE FIRST FLOOR 4 (8,936 SF.)
1 ST.FLOOR PLAN
SCALE:1/8"=1'-0" 0
a