HomeMy WebLinkAboutA3-22-Bldg C 2nd. Floor Plan_1-21-20 UNIT TYPE KEY BUILDING LEGEND
ALL'A'UNITS FIRE EXTINGUISHERS ❑ INDICATESSLOPE F.P. FIBER CEMENT PANEL
-1 BEDROOM TRUSSES 2%MAX
P.G. PAINTED GYP.SHEATHING
X DOOR KEY ABOVECHAIR RAILAND
ALL'B'UNITS SYMBOL INDICATES FIBER CEMENT PANEL BLOW
LOCATION OF UNIT RE:CORRIDOR DETAIL
'A'
-2 BEDROOM O WINDOW KEY DESIGNATEDAS
ANSITYPE C.J. C�FO�NTROLJOINT
ALL'C'UNITS (REFER TO SITE PLAN) IFLA )
OOR,CEILING&
® METER LOCATIONS INDICATES HVAC W
3 BEDROOM CONDENSING UNIT F.D.C. FIRE DEPARTMENT
-- CENTERLINE (REFER TO SITE PLAN&MEP)
CONNECTION
o RADON PIPE F.S.R.R. RIISER RROOMLER
1 HR.FIRE BARRIER WALL F.F. FINISH FLOOR
1'-0"
I IN C RECESS EILING B.F.F. BELOW FINISH FLOOR
»� LOCATION OF STAGGERED L--ARE:17/A2-00 B.F.C. BROOM FINISH,NON- REVISIONS
STUD WALLS SLIP SEALED CONCRETE
GENERAL NOTES:
•UNITS LABELED ANSI W TO MEET ANSI A117.1-2009 FOR TYPE A((1003 DWELLING UNIT
REFER TO FHA AND ANSI SHEETS FOR ACCESSIBILITY REQUIREMENTS.
•ALL FIRST FLOOR DOOR HARDWARE TO BE LEVER HANDLE.
•CHANGES IN FLOORING SURFACE TO BE 1/4"MAX.,1/2"MAX.CARPET PILE THICKNESS.
•THRESHOLD AT DOORWAYS TO BE 1/4"MAX.OR 1/2"W/45 DEGREE BEVEL.
•MAXIMUM FORCE FOR PULLING OR PUSHING SHALL BE 5 LB/FT.
•ALL CONTROLS AND OPERATING MECHANISMS SHALL BE MOUNTED
BETWEEN 15"-48"FOR A FORWARD OR SIDE APPROACH.
COORDINATEDWITH STRUCCTURALE OCATIONS.REFER ITO MANUFAICTURER FOR SPECIFIC SH ARE
REQUIREMENTS PERTAINING TO MATERIAL USED.
•METER AND FSRR ARE LOCATED ON A BUILDING-BY-BUILDING BASIS.
REFERENCE SITE PLAN FOR LOCATIONS.
•BUILDINGS MAY FLIP ABOUT CENTER LINE OR ROTATE,REFER TO SITE PLAN
FOR BUILDING LOCATION AND ORIENTATION.
•UNIT PLANS MAY BE REVERSED OR ROTATED WITHIN BUILDING PLAN.REFER TO BUILDING PLAN
FOR UNIT LOCATION AND ORIENTATION.
•WALL MOUNTED SERVICE EQUIPMENT AND SERVICE LINES TO BE PAINTED TO MATCH BUILDINGS.
•FIRE EXTINGUISHERS ARE TO BE A MINIMUM 2A 1 OB:C CLASSIFICATION AND SHALL COMPLY WITH -"
NFPA 10 GUIDELINES.REFER TO PLANS FOR LOCATIONS.(REFERENCE DETAILS 171A7-11,18/A7-11)
•ALL FIRST FLOOR DWELLING UNITS ARE TO MEET FHA AND ANSI'B'REOUIREMENTS UNLESS NOTED
OTHERWISE.REFER TO FHA AND ANSI SHEETS FOR MORE INFORMATION. M
W
�� U
J
LU Q J
G= W
O o¢
2 0_
C z�
4 3 z rr, 0
wQ L o
�LL Lu N�
137'-41/2" �f m z
L GO LccjJ
40%6" 1 12" 28'-0" 1 1/2" 28'-0" 1 12" 40'-6" O Z G
^ /1 W Cc
16'-6" 16'-6" o < Q Q.
BALCONY 9w BALCONY 16'5"
BALCONY m BALCONY O w
W
LJ o
BATHROOM BEDROOM BEDROOM BATHROOM m
❑' '❑ LIVING ROOM LIVING ROOM LIVING ROOM LIVING ROOM BEDROOM ❑�l ❑
BEDROOM -
B1-2(a) Q B 1-2(a)
CLOSE CLOSET Al-2(a) AI-2(a) CLOSET CLOSET Z
LU
Lima � __
N
, a o
DOWN DOWN �g N
y
BATHRO M O THROO LU
� LU O
LU
!KITCHEN
+ ,DOWN DOWN ' ' nBATHROOM
BEDROOM BEDROOM KITCHENBATHROOM KITCHEN KITCHENCLOSET InATTIC
1O 0 ___ A OV_SS ____ O___ ________ ______ 1 L aY1 _____ ____ a _______ 7 M M ~
o =10CLOSET KITCHEONO __ _________O O KITCHEN O O BATHR00 N CLOSET; KITCHENOBAT MBEDROOM DOWN ��� _-__ BEDROOM O L
11
.—. LL I
BATHRO M __________ __________ o THROO �-`'^'�_____ p
❑; DOWN DOWN ❑ Q
__________ j
o
am
CLOSE CLOSET B1-2gar(a) B1-2gar(a) CLOSET ;CLOSET U
Al-2gar(a) Al-2g*a)
oc
LIVING ROOM LIVING ROOM
BEDROOM ____ _
❑� ❑ LIVING ROOM LIVING ROOM BEDROOM ❑y 10 Q aN
BEDROOM BEDROOM BATHROOM
o DATE
BALCONY >
. BALCONY �
01 -21 -20
BALCONY BALCONY 0
= PROJECT
ce
'I J'I 82
40•-8" 1 1/2" 28'-0. 1 1/2" 26'-0" 1 1/2' 40'-6"
ar-a1rz" v SHEET NUMBER
a`
Y
w A3-22
1 BUILDING'C'
1 BUILDING TYPE 'C' SECOND FLOOR as (8,644 SF.) a 2ND.FLOORPLANS
SCALE:1/8"=1'-0" $