Loading...
HomeMy WebLinkAboutC3.0 Civil Details 05-14-2020 ----------------r--------------- 9. 2a" �OF MQVTgN 1-"MIN TOPSOIL L3/4"LTO PER- RHLL Iz -sOPE CHANDLER � No. 111 / W€BERM® wcoR a Pe�eo 2y ticewsEo 0 CRUSHED GRAVEL _ BASE-3"MIN. 48" TYPICAL ASPHALT CROSS-SECTION sue-BASE COURSE MI" Mnx VM Aa ssU Sheet 3 of 4 C3.0 SCALE;NTS AS REQUIRED W PEMT REWIRED 2z COMPACTED SUBGRADE 2"K2'0/8"SQUARE GALVANIZED STEEL TUBE SLOPE AWAY FROM BUILDING 41W RRE SET IN 18"OF CONCRETE(TTP.) OC w m E a'THICK POO vDEWAix 3/a"3/4"PER 1/2"PER V 3� \lox rnx V SLOPE SLOPE p IQ10 m MIN.3'OF 1•CRUSHED AGGREGATE BASE T 1[p0 Tr COMPACTED SUB-GRADE E O t DROP CURB SPILL CURB E a NOTES; SIDEWALK 10%MAX MAX SIDEWALK -III 7 0 1. SUBGRADE OR BASE COURSE COMPACTION SHALL CONFORM TO SECTION 02230(M.P.W.SPEC5.1996 ED.) (f) m NOTES. 2. CONTRACTION JOINTS SHALL BE PLACED AT 10'INTERVALS AND SHALL HAVE A MINIMUM DEPTH OF t"AND MINIMUM ` -D WIDTH OF GUTTER 1. CONCRETE DEPTH FOR STD.SIDEWALKS SHALL BE 4" a NOTE:TO AT A HEIGHT SO AS NOT C .z i MIN. 3. EXPANSION JOINT MATERIAL SHALL BE PLACED AT ALL P.C.S,P.T.S,CURB RETURNS AND AT NOT MORE THAN 300' TO BE OBSCSC MOUNTEDURED BY A VEHICLE PARKED IN THE 2. SIDEWALKS SHALL SLOPE AWAY FROM STRUCTURES AND INTERVALS.THE EXPANSION MATERIAL SHALL EXTEND THROUGH THE FULL DEPTH OF THE CURB AND GUTTER. DETACHABLE WARNING SURFACE SPACE. m m BUILDINGS AT 2%. 3. NO CURB AND GUTTER SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY THE CITY ENGINEER OR HIS (24"x WIDTH OF CURB RAMP) C v_ m 3. CONCRETE SHALL BE 4,000 PSI®28 DAYS. REPRESENTATIVE. o 'L -- 4. CONCRETE SHALL BE CLASS M-4000. ee 4. CONTRACTION JOINTS SHALL BE PLACED AT 5' S. CRUSHED GRAVEL BASE SHALL MEET THE REQUIREMENTS OF SECTION 02235(M.P.W.SPECS.,2003 ED.)FOR CURB ���o� �n t INTERVALS,EXPANSION JOINTS AT 20'INTERVALS. 3 AND GUTTER EXPANSION PROJECTS,WASHED ROCK MAY BE USED FOR THE GRAVEL BASE. z SIDEWALK CROSS-SECTION 3 CONCRETE CURB & GUTTER a HANDICAPPED ACCESSIBLE RAMP w 5 H.C. PARKING SIGN C C3.0 SCALE:NTS C.0 SCALE:NTS C.O.B.STD.DWG.NO.02528-1 C3.0 SCALE:NITS C3.0 SCALE:NTS o V Ol 4 3' 4 EXISTING GRADE c E%ISTING GRADE iT- �1 tT- DEPTH PER CIVIL PLAN - MA MAIN PROPER STBAC D - SETBACK PER ZONING r TYPICAL RETENTION POND SECTION REGULATIONS I 7 rl W COMPACTED TOPSOIL C3.0 5'TRANSITION SECTION FROM SC11E:1"=5' EXISTING CURB TO DROP CURB: CONCRETE WALK 1�1 0 6 j COMPACTED SOIL MN 4H:1V MAX EXPANSION JOINTS COMPLETELY 1�, AROUND SIDEWALK SECTION H07E5: BOARD 1 Ybz18"DEEP HOLE 1'FIR1. ONE"U"RACK HAS CAPACITY TO HOLD 2 BIKES. MAX.THROAT WIDTH 2. MAINTAIN 24"-30"SPACING BETWEEN"U"RACKS. FILLED WITH CONCRETE FLOW DEPTH - 35 COMMERCIAL 3. MAINTAIN 24"FROM ANY PARALLEL WALL OR OBJECT. 40'INDUSTRIAL CURB&APRON POURED MONOLITHIC 4. MAINTAIN 30"FROM ANY PERPENDICULAR WALL OR OBJECT. PROVIDE 6"COMPACTED UNLESS OTHERWISE APPROVED TOPSOIL TO FLOW DEPTH CONTRACTION JOINT EXPANSION JOINTS AT CURB RETURNS 6 SIGN POST SETTING DETAIL B SWALE CROSS SECTION DETAIL (2)TYPICAL BICYCLE RACK _)SIGN NTS C3.0 SCALE:NTS SIDEWALK CONTRACTION JOINTS j I BACK OF CURB C3.0 SCALE:HIS SPACED AT 5'INTERVALS-MIN. FLOW LINE DEPTH 1". EXPANSION JOINTS TO BE PLACED AT 25' EDGE OF GUTTER 20 MIL BE IMPERMEABLE UWM OF REWIRED INTERVALS. O DIVER WER TOP OF PIPE (12'MR 12.0-.B'6 SACKFUL VARIABLE 18'FOR 102'0 AND>) CONTRACTION JOINTS TO BE SPACED (5.5'TYPJ AT 10'INTERVALS IN CURB&GUTTER ASPHALT/SIDEWALK /D&L J-4126(SOLID COVER)OR J-4227(GRATE) EXPANSION JOINT MATERIAL SHALL BE 1/2"THICK PRE-FORMED BITUMINOUS TREATED FIBERBOARD FILLER. TRENCH GRATING(OR APPROVED EQUAL) ALL CURB REPLACEMENT SHALL BE DONE WITH INTEGRAL CURB AND GUTTER UNLESS OTHERWISE APPROVED. 3'-0" STREET SURFACE `( GRADE ESTABDSHED AS 1/4"RISE PER FOOT FROM TOP OF ADJACENT FULL HEIGHT CURB 3V MP.) 12'(TVPJ R MATCH EXISTING SIDEWALK GRADE soup MR PIPE ` 6" 2' 1/2"PER 1 SIDEWALK DRIVEWAY APRON (VARIES)A�'i�T'•� " •,• 1/4"PER FOOT SLOPE STREET SURFACE EXPANSION � � ...� � � "�. JOINT TION VIEW (NTS)7^r � CONTECH STORMWATER DETENTION CHAMBER SEC �1 t.' .�� REINFORCE WITH#4 4 BASE COURSE REBAR REINFORCING TABLE V �I NOTES:THE WIDTH OF THE INVERT VARIED J"wASHED ROCK •BEARING Fr FROM THE C.O.B.DETAIL TO SATISFY THE CURB&GUTTER OCMP A 0B REINFORCING PRESSURE DESIGN REQUIREMENTS OF THIS APPLICATION. MIN.6"THICK RISER (psF) FINISHED STREET SURFACE TO BE 1/8"TO M-4000 CONCRETE NOTE x< s S: •OR MATCH EXISTING OR REQUIRED SIDEWALK WIDTH 1/4"ABOVE EDGES OF DOUBLE GUTTER. §m wN+zocew 1. CONCRETE SHALL BE M-4000 --- - - -- -- � +zacEw 2. COVERS MUST BOLT DOWN TO FRAME } ( g+aacEw MATERIAL a�sERT .NT.-. e aa�„rF� J m�+aocEw Q�1' ¢ ng+o-ocev O _ ngaacEw 4 ugaoCLw AyA ngaacEw I+i SECTION VIEW 1� O ,Q CONCRETE STORM DRAINAGE CHASE 1, 3' WIDE VALLEY GUTTER 2 NON-RESIDENTIAL APPROACH ,3 CONTECH UNDERGROUND DETENTION CHAMBER C3.0 SCALE:NTS C3.0 SCALE:NTS C3.0 SCALE:NTS C.O.B.STD.DWG.NO.02529-12 C3.0 SCALE:NTS 1" U 20'-0" 0' FRAME AND SLOTTED TOP COVER WEIR ELEV.479.00 GRATE 3"MIN.GRADE SLOT WIDTH-0.9 RINGS RIM ELEV. 4798.33 INLET PIPE RIM E INLET PIPE ELEV. OUTLET PIPE II/ OUTLET PIPE 1 rt ` INV.IN INV.OUT " INV.OUT •• 4794.00 9" 4794.00 SUMP_4 4715,10 + CONTRACTOR CONTRACTOR a^ TO GROUT 4"J BASE SLAB. TO GROUT SLAB 1"WEEP HOLE (TYP) OUTLET PIPE S DIA LAB A (TYP) OUTLET PIPE 56"DA. Issue Date:511412020 SE BASE SLAB PLAN VIEW Li PLAN VIEW SECTION VIEW SECTION VIEW 30 CUBIC YARD DUMPSTER W/COVERED ROLL-OFF TOP „ CONSTRUCTION DUMPSTER DETAIL 5 POND OUTLET STRUCTURE C3mO ,6 UNDERGROUND CHAMBER OUTLET STRUCTURE C3.0 SCALE:NTS C3.0 SCALE:NTS C3.0 SCALE:HIS #171293