HomeMy WebLinkAbout14 - Design Report - Town Pump #8 - Sewer, Water SANITARY SEWER AND WATER MAIN EXTENSION DESIGN REPORT FOR: TOWN PUMP #8 LOT 1A OF MINOR SUBDIVISION 454A BOZEMAN, MT Prepared By: MADISON ENGINEERING Madison Engineering 895 Technology Blvd Ste 203 Bozeman, MT 59718 (406) 586-0262 January 2014 WATER MAIN EXTENSION DESIGN REPORT SANITARY SEWER AND TOWN PUMP #8 LOT 1A OF MINOR SUBDIVISION 454A BOZEMAN, MT 1-7 +u1. f 1 e i4iw.^k 4 Madison Engineering 895 Technology Blvd Ste 203 Bozeman, MT 59718 (406) 586-0262 January 2014 W ater TOWN PUMP#8 LOT lA OF MINOR SUBDIVISION 454A WATER SYSTEM DESIGN REPORT A. General This design report will give an overview of the proposed water main extension for the development of the Lot lA of Minor Subdivision 454A on Cottonwood Road off of Huffine Lane in Bozeman. The report includes a description of the proposed water main and design parameters. The proposed improvements are anticipated to be constructed during the summer of 2014. Once the water main is constructed and approved, the main will become a part of the City of Bozeman system. The following references were used in the preparation of this report: a. COB Design Standards and Specifications Policy,2004. Addendum#4 b. COB Modifications to Montana Public Works Standard Specifications(MPWSS). c. City adopted MPWSS and Adopted Addenda d. WQB Circular No. 1 e. City of Bozeman Zoning Map f. Uniform Plumbing Code B. Existing Water Supply The proposed water main extension will be served from the existing City of Bozeman water distribution system in Cottonwood Road. A stub was provided for this extension with the development of the Cottonwood Road water main, which was installed for the Loyal Gardens subdivision. The following information regarding pressures of the existing system obtained from the City of Bozeman: Fire Hydrant —Golden Gate and Advanced Drive. Hydrants 2201 and 2202 Static Pressure: 115psi Pitot Pressure: 80 psi Residual Pressure: 110 psi Hydrant Discharge Calculation—2.5 inch port, during test Qt= 167(pt).5 Qt= 167 x 80,5 Qt= 1,494 gpm Distribution Main Capacity—Fire flow at minimum residual pressure Q,=Qt[(Ps—Pr)/(Ps—Polo." Q,= 1,494[(115 —20)/(115—80)]0-" Q,=2,562 gpm Qt= Hydrant Discharge During Test Q,= Fire Flow at Residual Pressure PS= Static Pressure LOT I—Water Design Report Page I of 3 P, = Minimum Residual Pressure Pt= Pitot Pressure C. Proposed Water System The proposed water main extension will consist of approximately 176 if of 8" Class 51 Ductile Iron Pipe. The proposed main will connect to an existing 8-inch stub, with a gate valve, and dead end at a blow-off. Included in the appendix of this report is a plan and profile of the proposed water main. The layout of the proposed water main meets the City of Bozeman design criteria and will be located both within the right-of way and a proposed 30' wide easement and separated from the proposed sanitary sewer main by a minimum distance of 10 feet. A fire hydrant will be installed approximately mid way, fulfilling the distance requirement for fire hydrant spacing, as well as assisting in flushing of the main. A gate valve will be installed at the connection point to the existing stub. No water services will be connected to this main for the proposed Town Pump. D. Capacity Analysis A capacity analysis was performed on the proposed water main extension. The water main extension has been designed to meet the maximum day demand plus fire flow during the peak hour. The zoning for the 6-acre lot is Business (B2). The City's Design Standards does not specifically reference water usage for a B2 site so we propose to use the Sanitary Sewer Design Criteria for evaluating the water usage. Based on Table V-1 of the City's design standards it is estimated a B2 lot will produce 2,000 gpd of wastewater flow. Based on this value, the 6.0 acre development, at full build out, will have an estimated water usage of 12,000 gal/day, or an average daily demand of 25 gpm, based on an 8- hour day. In addition to the average daily demand, the water main extension must account for peak periods of daily use. Peaking factors are applied to the demand and account for these peak periods in daily use. The peaking factors used are maximum daily use and peak hour and are obtained from the City of Bozeman Design Standards. Table 1 shows the peaking factors and the resultant flows from those factors applied to the average daily demand of 25 gpm. TABLE 1 PEAKING FACTORS Flow Designation Peaking Factor Flow m Average Day Demand 1 25 Maximum Day Demand 2.3 57.5 Maximum Hour Demand 3 75 The required fire flow for a Type V-B structure is 2,500 gpm. A Hazen-Williams "C" Factor of 130 was used in the pipe evaluation. The working residual water pressure shall not be less than 20 psi at any point in the water distribution system under maximum day plus fire flow. The velocity shall not exceed 15 feet per second through the main line. LOT I-Water Design Report Page 2 of 3 Results Based on a fire flow demand of 2,500 gpm and a maximum hour demand of 75 gpm a maximum hour flow of 2,575 gpm is required. However, Section B105 of the 2009 IFC allows for a 75% reduction in fire flow when the building is provided with an automatic sprinkler system, which this building is. Based on the allowed reduction, the required fire flow is 625 gpm, and with the maximum hour demand of 75 gpm a maximum hour flow of 700 gpm is required. Flow analysis of an 8-inch D.I. pipe with a C value of 130 can provide the required 700 gpm with a pressure drop of approximately 0.7 psi from 115 psi to 114.3 psi, well above the minimum of 20 psi. The pipe velocity is 4.47 Vs. Capacity analysis calculations outlining the capacity of the proposed fl- inch pipe are included in the appendix of this report. TABLE 2 ANTICIPATED FLOWS Flow Designation Flow m Fire Flow Flow m Maximum Day 57.5 625 682.5 Maximum Hour 75 625 700 E. Conclusion Based on this analysis, the proposed 8-inch water main extensions for the development of Lot 1 A of Minor Subdivision 454A provides adequate service to meet the peak hour demand and fire flows for the development. This project will require the approval of the City Engineer and MDEQ. CC �I LOT I—Water Design Report Page 3 of 3 Appendix Lot IA Minor Subdivsion 454A Hydrant Discharge Calculation: 2.5 inch port, during test Prepared by Madison Engineering Static Pressure: 115 psi Pitot Pressure: 80 psi Residual pressure: 110 psi Qt= 167(p).5 Qt= 1,494 gpm p=pitot pressure Qt=calculated flow during test Fire flow information provided by City of Bozeman Lot IA Minor Subdivsion 454A Distribution Main Capacity Fire flow at minimum residual pressure Prepared by Madison Engineering Qr= Qt(Ps—Pr/Ps—Pt)o.sa Qr= 1494 ( 115 - 20)/( 115 _ 80 )0.54 Qr= 2,562 gpm Static Pressure: 115 psi Pitot Pressure: 80 psi Residual pressure: 110 psi Hydrant Discharge During Test: 1494 gpm Qr= Fire Flow at Residual Pressure Qt= Hydrant Discharge During Test PS= Static Pressure Pr = Minimum Residual Pressure Pt= Pitot Pressure Page 1 Distribution Main Capacity Town Pump #8 Project Description Friction Method Hazen-Williams Formula Solve For Pressure at 2 Input Data Pressure 1 115.00 psi Elevation 1 4800.00 ft Elevation 2 4800.00 ft Length 172.00 ft Roughness Coefficient 130.000 Diameter 8 in Discharge 700 gal/min Results Pressure 2 114.30 psi Headloss 1.62 ft Energy Grade 1 5065.57 ft Energy Grade 2 5063.94 ft Hydraulic Grade 1 5065.26 ft Hydraulic Grade 2 5063.63 ft Flow Area 0.35 ft2 Wetted Perimeter 2.09 ft Velocity 4.47 ft/s Velocity Head 0.31 ft Friction Slope 0.00944 ft/ft Bentley Systems,Inc. Haestad Methods Sd %X4d iMaster V8i(SELECTseries 1) 108.11.01.03] 1/14/2014 9:00:15 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06796 USA +1-203-755-1666 Page 1 of 1 w- o N } m Z m I 3m PROPOSED TOWN �I PUMP DRIVEWAY / POTHOLE AND VERIFY EXISTING s �' ( PROPOSED 4" PVC WATER MAIN DEPTH AND II I41, PROPOSED(FIRE HYDRANT , SANITARY SEWER SERVICE a LOCATION PRIOR TO ;I I BURY LINE: 4843.63 � CONSTRUCTION. NOTIFY i 46.7' 0 8.5'BURY DEPTH y e oy /// SEE SHT C3.1 S PROPOSED 6" D.I. 0 ENGINEER BEFORE PROCEEDING. s - + HYDRANT LEAD 1� EXT'G EDGE OF ;,^- ( I b c PROPOSED CURB ' 1 'PAVEMENT I I _ _ _ /_ ( _ _STOP AND BOX WATER D.I. �`- WATER MAIN L I.. I c In I _ — - -1 = 0+00 - -_0+sO t+oo y" y� 1+50 1+77 I o W - 1 }—W W --I--W W STA 0+00.00- ^ + I+I PROPOSED WATER -- nM— r:.+— CUT EXT'G WATER MAIN TO SAWCUT, REMOVE 21.7 STA 0+76.34, 78.54' L7 / I IMAM BLOW-OFF d INSTALL j6' GATE VALVE (W) AND REPLACE EXT'G INSTALL 12"x6" TEE by 5 �i Z AS NECESSARY PAVEMENT I I TAPPED BLIND FLANGE, o I / FLANGED END ADAPTOR S A S — S s S� S & CORP. STOP • �'� "T _ _ " EXT'G B" SANITARY / o _I PROPOSED 12` WATER suo<sa SEWER MAIN \ PRDPOSED 8` SEWER 14 X i MAIN EXTENSION MAIN EXTENSION EASEMENT L� I PROPOSED CURB I I DRAWN BY:BL8 IREVIEWED BY:CGB RB EXT'G BAWIRE FENCE ' INSTALL JOINT RESTRAINTS ON j I TO BE REMOVED o PROPOSED GUTTER ALL JOINTS WITHIN 2e OFa PROJECT ENGINEER:CGB I I �{ �� o f�� FITTINGS. INSTALL POLYWRAP IF I I EXT'G OVERHEAD POWER REO (RED 8Y CITY. DESIGNED BY:BLB PROPOSED �! EXT'G GAS II 9 OVERHEAD POWER I I SCA1,13 D 10 20 +0 Jf,j✓ I II PROPOSED CURB & Ii + GUTTER RAISED MEDAIN 1-20 V4 � O a NVATER MAIN PLAN HORZ. SCALE: 1" 20' ('"a F" 4846 I - j 4846 TOP BACK PROPOSED O EXISTING BLOW-OFF _ OF CURB VALVE BOX 4844 ASSEMBLY TO BE REMOVED 4844 _ _ _ W AND DISPOSED_ — _ _ _ _ — — -PROPOSE E-+ 4842 I'\ 1 I CURB BOX B' MIN 4842 T ii PROPOSED - 4840 STORM DRAIN 4840 ii 6.5' MIN PROPOSED 2" STA. 1+6&56 COPPER SERVICE 4838 i COVER - PROPOSED LINE 4838 PROPOSED 12" CL 51 DI CURB STOP L=10', 5=0.o% 4836 .... WATER MAIN, 167 LF INV. 4835.22 4836 -0.55% 4834 T a.o� o� o STA. 1+66.57 .... .I 4834- w SA 0+0000 STA. 0+76.34 (LT) INSTALL TAPPED BLIND STA. 1+76.66 ��,( � REMOVE EXT'G BLOW-OFF ASSEMBLY, PROPOSED 12"X6" TEE FLANGE, FLANGED END INSTALL WATER 4832 W�'XE 1M DI INSTALL 12" GATE VALVE(MJxMJ), 6" D.I. HYDRANT LEAD ADAPTOR & CORP STOP . MAIN BLOW-OFF 4832 POTHOLE AND VERIFY EXISTING WATER MAIN INV. 4835.22 INV. 4835.22 �t AND BEGIN NEW 12" WATER MAIN INV. 4834.80 U WATER MAIN DEPTH AND h INV. 4835.02 (ASSUMED) LOCATION PRIOR TO 4830 STA. 1+34.55 STA. 1+39.37 4830 CONSTRUCTION. NOTIFY 4" S.S. SERVICE A 4" S.S. SERVICE B ENGINEER BEFORE PROCEEDING. INV. 4830.09 INV. 4830.61 4828 - 4828 �1 O I�.Z W N O N 0 0+00 1+00 2+00 2+25 U p � � G RATER MAIN PROFILE HORZ. SCALE: 1" = 20' m VERT, SCALE: 1` 4' SHEET C4"0 7'0XVN PUMP WATER MAIN PROJECT:12-137 DATE:12.12.13 Wastewater TOWN PUMP#8 LOT 1A OF MINOR SUBDIVISION 454A WASTEWATER SYSTEM DESIGN REPORT A. General This report will give an overview of the proposed wastewater collection system for the proposed development of the Lot IA of Minor Subdivision 454A on Cottonwood Road off of Huffine Lane in Bozeman. The zoning for the 6 acre area lot served by the sewer main extension is B2, Community Business District. The proposed improvements are anticipated to be constructed during the summer of 2014. Included in this report is a description of the proposed wastewater collection system and design parameters. Once the wastewater system is constructed and approved, the system will become a part of the City of Bozeman system. The following references were used in the wastewater facilities design and capacity analysis: a. COB Design Standards and Specifications Policy,2004. Addendum#4 b. COB Modifications to Montana Public Works Standard Specifications (MPWSS). c. City adopted MPWSS and Adopted Addenda d. COB Wastewater Facility Plan, 2007 e. WQB Circular No. 2 f. City of Bozeman Zoning Map The procedures and parameters outlined in the COB Design Standards and Specifications Guide were used in the design of the sewer infrastructure for the proposed development. B. Capacity Analysis The effluent generated from the proposed development will flow west into an existing City of Bozeman sanitary sewer main located in Cottonwood Road. An 8-inch sewer stub has been provided to serve the lot. The proposed sewer main has been sized to flow at no more than 75-percent of full capacity at peak hour conditions of full build out. An infiltration rate of 150 gallons/acre/day was added to the design peak flow. A Manning coefficient of 0.013 was used for PVC pipe. Table V-1 of the City of Bozeman's Design Standards recommends wastewater flows based on zoning. The B2 zoning estimates 2,000 gallons per day per acre. The average daily flow based on the estimated wastewater flows is: 2,000 gpd x 6 acres= 12,000 gpd A peaking factor was calculated based on the following formula: LOT I A—Wastewater Design Report Page I of 2 Qmax i Qave= (18 +P0'5)/(4+ P0.5) (P=Population/thousands) Based on the equivalent population, a peaking factor of 4.21 was calculated. The calculated peaking factor is included in the appendix of this report. The peak flow rate anticipated from the development based on an average daily flow of 12,000 gallons with an infiltration rate of 150 gal/acre/day using 89-gallons per capita per day is: Peak Flow Rate = (12,000 gpd x 4.21) + 900 gpd = 51,420 gpd = 107 gpm (based on an 8 hour day) = 0.24 cfs The sewer main size for the development will be an 8-inch, based on minimum required pipe size and slope. An 8-inch PVC sewer main at 0.4% slope has a capacity of 0.70 cfs at 1/4 pipe depth which has adequate capacity for the proposed peak flow of 0.24 cfs effluent generated from the 6-acre site. Calculations are provided in the appendix of this report. C. Proposed Collection System PVC pipe meeting COB specifications will be used for all the sewer mains. The sewer main will be 8-inch diameter with a maximum manhole spacing of 400 feet and a manhole barrel size of 48-inches. Manholes will be constructed according to COB specifications. All sewer services will be 4-inch PVC installed at 2% minimum grade. Sewer services will connect into the main with in-line gasketed wyes. A 4-inch sewer service with a grade of 2.0% can convey approximately 60 gpm at 50% capacity. A plan and profile of the proposed sewer main extension is shown in the appendix of this report. The sewer main will be located within a 30-foot wide utility easement and located a minimum of 10-feet from the proposed public water main. D. Downstream Capacity Analysis A capacity letter has been received from the City of Bozeman indicating capacity in the existing system. A copy is included in the appendix of this report. E. Conclusion As outlined above, the 8-inch sanitary sewer main serving Lot IA of Minor Subdivision 454A, has the capacity for the effluent generated from the 6 acre tract. This project will require the approval of the City Engineer and MDEQ. LOT IA—Wastewater Design Report Page 2 of 2 Appendix Sewer Main Extension Lot lA of Minor Subdivision 454A Peaking Factor for B2 Zoned Land Wastewater Daily Flow Rate= 2,000 gpd/acre Acres= 6 acres Total Wastewater Flow Rate= 12,000 gpd Residential Usage per person= 89 gpd Equivalent Residents= 135 Q(n,ax) = 1 g +P o.so P=Population/thousands Q(ave) 4 +P 0.50 Peaking Factor = 4.21 Peaking Factor for B2 Zoned Land ®�130 THE CITY OF BOZEMAN 20 E. OLIVE P.O. BOX 1230 * BOZEMAN, MONTANA 59771-1 230 - ENGINEERING DEPARTMENT 880�'� PHONE: (406) 582-2280 ® FAX: (406) 582-2263 CO.TX January 15, 2014 Chris Budeski P.E. Madison Engineering 895 Technology Blvd, Ste 203 Bozeman, MT 59718 RE: Town Pump - Water and Sewer Main extension capacity Dear Chris: The City of Bozeman is currently reviewing the sewer and water extension plans and specifications for the above referenced project. Adequate capacity exists in the City's sewer collection system, and adequate pressure and capacity exist in the City's water distribution system to provide service for the property served by the proposed extension. In accordance with our policy, City of Bozeman final approval will not be given until the project plans have successfully completed the City's review process and written approval for the project is received from the Montana Department of Environmental Quality, Water Quality Bureau. Please contact me if you have any questions. Sincerely, Dustin iJohns n, P.E. Project Engineer cc: John Alston, Water/Sewer Superintendent Department of Environmental Quality ERF Project File HOME OF MONTANA STATE UNIVERSITY GATEWAY TO YELLOWSTONE PARK 8-inch PVC Pipe Capacity Project Description Friction Method Manning Formula Solve For Discharge Input"Data Roughness Coefficient 0.013 Channel Slope 0.40 % Normal Depth 6 in Diameter 8 in Results Discharge 0.70 ft'/s Flow Area 0.28 ft' Wetted Perimeter 1.40 ft Hydraulic Radius 2 in Top Width 0.58 It Critical Depth 0.39 ft Percent Full 76.0 % Critical Slope 0.00773 ft/ft Velocity 2.48 f/s Velocity Head 0.10 ft Specific Energy 0.60 ft Froude Number 0.63 Maximum Discharge 0.82 tt'/s Discharge Full 0.76 ft'/s Slope Full 0.00333 ft/ft Flow Type SubCritical GUI=Ir►put,Data Downstream Depth 0 in Length 0.00 ft Number Of Steps 0 G1%F Outpuf Data; Upstream Depth 0 in Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 % Normal Depth Over Rise 75.00 % Downstream Velocity Infinity ft/s Bentley Systems,Inc. Haestad Methods SdbeWilelPilikh faster V81(SELECTseries 1) [08.11.01.03] 1/16/2014 8:28:10 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06796 USA +1-203-765-1666 Page 1 of 2 8-inch PVC Pipe Capacity GVF Output Data Upstream Velocity Infinity ft/s Normal Depth 6 in Critical Depth 0.39 ft Channel Slope 0.40 % Critical Slope 0.00773 ft/ft Bentley Systems,Inc. Haestad Methods SdbetiNa)PRO lAaster V8i(SELECTseries 1) [08.11.01.03) 1116/2014 8:28:10 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06796 USA +1-203-765-1666 Page 2 of 2 M I di �I •✓,• _ N o II 1 .��I II 3J - PROPOSED TOWN 0 in ]0 40 PUMP DRIVEWAY^• i" zo I U ��.. . PROPOSED FIRE HYDRANT _ POTHOLE AND Vc"RIFY �- o EXISTING SEWER MI,41N 4 ' 6�1' I ,o I ( - vl DEPTH AND LOCATION PRIOR TO CONSTRUCTION. NOTIFY ENgNEER TOR I I EXT`G EDGE OF -:,_,», ,LPAVEMENT TO CONSTRUCTIO EXTG 12 TT WATER MAIN o I I I y yy yi -_ g, „-. 1W =W lV Y =-l.W 5J W �_W W _ Y! y R' PROPOSED 30' WIDE STA 1+60.26 - FM-FN STA 0+011 c 21.7' I UTILITY EASEMENT I // I 8" PVC SDR 35 SEWER Z- EXT'G SSMH jJ36 \ I a yy yy STUBBED AND CAPPED - .. 0 16.9'EAST OF MANHOLE RIM 4843.58 0+00 - II 1+00 I 1+50 S=0.4% T 4 c 9 INV IN (E) 4828.19 _5 S I''� I S -t S n , NOTE:SEE EAN OUT\ICAL DETAILS INV OUT(W) 4827.99 -� � I � STA 1+43.36 � T SHT M-0: CLEAN OUT e _ -- --- - - - - PROPOSED MANHOLE #1 SHT M-I: GREASE INTERCEPTOR x - - RIM 4844.44 STA CONNECT 0 aiocsxl REMOVE EXT'G CAP AND CONNECT � / � �� INV IN (E) 4828.75 TO EXT'G 8" SEWER STUB PROPOSED 8" SDR 35 STA 1+43.36 INV OUT(W) 4828.55 PVC SEWER MAIN PROPOSED 4" S.S. INV 4826.2t (ASSUMED) II 134t LF - --� I,� SERVICE A (LT) STA 1+43.36 FRAME AND COVER TO BE EITHER D&L A-1172 WITH 1" COVER, MCI 305 FRAME, ,I �I �I i p o SEE SHEET 3.1 . 8"PVC SDR 35 SEWER ' 305A COVER, OR IFCO 772 FRAME, 772-B COVER, OR DEETER 1025. I ��. I STUBBED AND CAPPED COVERS SHALL HAVE TWO i" PICK HOLES. 'I STA 14" S.S. Z5'SOUTH OF MANHOLE DRAWN BY: 8L8 �7,-� I EXT'G BARBW7RE FENCE I PROPOSED 4" S.S. 5=1.0% REVIEWED BY:CGB TO BE REMOVED SERVICE 8 (LT) _ I x a ( PROPOSED CURB & SEE SHEET 3.1 PROJECT ENGINEER:CGB ALL JOINTS BETWEEN MANHOLE SECTIONS, MANHOLE RING & o GUTTER DESIGNED BY:BL8 ADJUSTABLE RINGS �)I FOR ALL JOINTS EXCEPT BETWEEN SEWER PIPE AND MANHOLE WALL. <_ TOP SECTION, AND AROUND SEWER PIPE INTO MANHOLE SHALL BE I 2" MIN., 12" MAX. t EXT'G OVERHEAD POWER `I ( I WATERTIGHT. JOINTING MATERIAL SHALL BE EXT'G OR EQUAL TO BE RELOCATED N \ J/ PROPOSED OVERHEAD POWER I I EXT'G GAS -) a I w 2'_0" 5" 5" PRECAST REINFORCED CONCRETE MANHOLE RISER 4'-0" AND ECCENTRIC CONE TOP MANUFACTURED IN PROPOSED CURB& ACCORDANCE WITH ASTM DESIGNATION C-478. GUTTER RAISED MEDIAN m I I P, MANHOLE III � I STEPS AT PROPOSED STORM DRAIN �o (yj 16" CENTERS I' I ( i GROUT INVERT TO SPRINGLINE OF PIPE IF GAP BETWEEN SANITARY SEWER MAIN PLAN a EH PIPE A CHANNEL 19 m HORZ. SCALE: 1" 20' v1 , GREATEE R THAN 1/8". m r �n O1 r: ae m m 4'-0" PRE-CAST CHANNEL m ro x c6 (MIN.) FLOWLINE n m y VARIABLE L, :2 p^ e N p^ SHELF-SLOPE 7"PER 12"MAX A POURED- FOOTSEECT�AARED CHANNEL U m_ ±o m ZFOR m W IN-PLACE BASES) x >> �z�>> Q r FLEXIBLE GASKETED JOINT (TYPICAL N a a w" FOR PRECAST BASES - SEE DETAIL) I A CH4 L- pPE 4846 FINISH ( 4846 P4 GROUND GROUND GRADE I, r� 4844, _. _. .. �.___. ___ ._ -. 4844 A PRECAST OR POURED-IN-PLACE BASE. -- �4 '-D" POURED-IN-PLACE BASE, MINIMUM BARS - 1 Ui CONCRETE THICKNESS BELOW PIPE IS 4842 I I 4842 5'-4" DIA. O.C. 8 INCHES. PRECAST BASE, MINIMUM STA. 0+34.42 THICKNESS IS 6 INCHES. ALL BASES : EXISTING GAS LINE (MIN) REINFORCED AS SHOWN. 4840 INV. 4839.65 4840 FF-�-- (3' DEPTH ASSUMED) p RADIUS OF 4636 I I 4838 W SLOPE AT 1" PER FOOT. MANHOLE STA. 0+17.13 CHANNEL TO FULL PROPOSED STORM PIPE DEPTH NOTE" 4836 - DRAIN CROSSING -- - - 4836 24- STORM DRAIN MANHOLES SHALL NOT HAVE PROPOSED 8" PVC SDR 35 u; FORMED CHANNELS AND THE LOWEST PIPE 4834 I - - - - SANITARY SEWER MAIN 4834 INVERT SHALL BE 9" HIGHER THAN BOTTOM OF 1 1 16.9 LF 0 0.40% DIA. OF +� MANHOLE. I 1 STA, 0+12.05 PROPOSED 8' PVC4h/, SEWER PIPE 4832 -I REMOVE EXT'G CAP. CONNECT -- SDR 35 SEWER STUB - 4832 Fa o I TO EXT'G 8" SEWER STUB. AND CAP 7.5' SOUTH STA. 1+60.26 d INV. 4828.2 (ASSUMED) OF MANHOLE, 5=1.0% PROPOSED 8" PVC SDR 35 4830 SEWER STUB AND CAP 4830 a SECTION A-A 16.9' EAST OF MANHOLE p N o - INV. 4829.02 DETAIL - 4828 - .____ _. __ - .. 4828 0 r"E'i p � E«T POTHOLE AND VERIFY STA. 1+23.11 (LT) STA. 1+28.05 (LT) C1,0 SANITARY 4., ER:�ZAj�Tj-jOLE EXISTING SEWER MAIN PROPOSED 8" PVC SDR 35 C.O.B. STO. DWG. NO. 02720-3 DEPTH AND LOCATION 4826 - =SANITARY SEWER MAINPROPOSED 4" PVC PROPOSED 4"PVC SERVICE 8 4826 � � v SANITARY SEWER S PRIOR TO CONSTRUCTION. 1343 LF®0.40% INV,SERVICE 452& A A SANITARY 4828.70 NOTIFY ENGINEER PRIOR 4824 4824 TO CONSTRUCTION - Ul. MN M'M M:d Vu'l tfi tp '�-OI V'.> 4 Z mim SHEET C3.® 0+00 1+00 2+00 2+25 TOWN PUNIP SANITARY SEWER MAIN PROFILE SEWER MAIN HORZ. SCALE: 1" = 20' VERT. SCALE: 1" 4' PROJECT:12-137 DATE:12,12.13