HomeMy WebLinkAbout17 - Design Report - Northwestern Energy Facility Renovation - Storm S A N D E R S 0 N t!•�
STEWART
October 17, 2017
Project No. 17032
STORM DRAINAGE PLAN
FOR
C/S 157 A - NORTHWESTERN ENERGY FACILITY RENOVATION
BOZEMAN, MONTANA
OVERVIEW NARRATIVE
The purpose of this drainage plan is to quantify storm drainage improvements required for the
proposed building additions on the NorthWestern Energy property at 121 E Griffin Drive in
Bozeman, Montana. The approximately 15-acre lot will include two (2) new building additions, a
new customer parking area and a new employee parking area. Additional improvements will include
new drive aisles, sidewalks,landscape and utilities.
Generally, the storrriwater runoff within the apartment complex will be conveyed via inlets and pipes
to one large infiltration basin located in the northwest corner of the property. Under a separate
project a new road is being constructed from Manley Road, south of the pond, to the East Gallatin
Recreation Center's parking lot. The preliminary road layout is delineated within the sheets of the
attached plan set. The new road will allow new access points for Mergenthaler (NorthWestern
Energy's neighbor to the west) and the City of Bozeman (NorthWestern Energy's neighbor to the
north). As a result of this project, the stormwater runoff from Mergenthaler's property, a portion of
Manley Road, a portion of E Griffin Drive, NorthWestern Energy's property, a portion of the
property to the east of NorthWestern Energy and the City of Bozeman's property will all be diverted
into the exiting infiltration basin on Northwestern Energy's property.
This report presents a summary of calculations performed to quantify the stormwater runoff for the
improved site. All design criteria and calculations are in accordance with The City of Bo.Zeman Design
Standards and Specifications Policy, dated March 2004. The site stormwater improvements have been
designed with the intent to meet the current City of Bozeman drainage regulations for the entire site
to the extent feasible.
To Plan and Design
Fk119TFIRM IV
Enduring Eommunities...
www. sandersonstewart. com
Specific site information and criteria are described below:
I. Project Information
A. Address: The physical address for the site is 121 E Griffin Drive, Bozeman, MT
59718
B. Legal Description: Tract 91-94 and COS No.157A
C. Total Area: The analysis area of the site is approximately 27.55 acres. The total
areas below do not align with the existing property area due to the new road
configuration.
North`y/estern Energy and Griffin: 14.00 acres
Mergenthaler: 4.4 acres
New Road &Manley: 3.46 acres
City of Bozeman: 4.74 acres
Property East of NWE: 0.93 acres
Total: 27.55 acres
D. Existing Impervious Area:
Northwestern Energy and Griffin: 11.32 acres
Mergenthaler: 3.83 acres
New Road&Manley: 0.303 acres
City of Bozeman: 4.74 acres
Property East of NWE: 0.93 acres
Total: 21.1 acres
E. Post-Development Impervious Area (Gravel/Asphalt/Concrete/Roofs): As a
result of the development, the site will exhibit the following qualities:
Northwestern Energy and Griffin: 12.78 acres
Mergenthaler: 3.83 acres
New Road&Manley: 1.82 acres
City of Bozeman: 4.74 acres
Property East of NWE: 0.93 acres
Total: 24.1 acres
F. Type of Development: The development will be warehouses and office space.
II.
A. General Design
1. The existing discharge point for all five areas is the East Gallatin Recreation
Center Pond. With the construction of the new road the proposed discharge
V:17032_NWE_Storm_Drainage_Plan_101617_SC 2 (10/16/17)SN/jil
location will be into a roadside drainage ditch that will convey flow into an
existing swale that discharges into the East Gallatin River.
2. The stormwater facilities are designed to remove pollutants such as solids,
silts, oils, and greases. There is no oil/water separator required on site. The
infiltration basin will allow for large particles to settle and filter any smaller
particles through infiltration.
3. Storm Sewers:
a. Alignment between manholes is generally straight. '
b. Storm sewer systems are designed slope and pipe diameter as
to ensure a velocity of 3-fps.
C. Pond inlets and outlets will be protected with riprap to prevent
erosion as shown on the Grading Plan.
d. The storm sewers within the public access easement of the new road
will be maintained by the City of Bozeman. Pipe material will either
be RCP or PVC. The minimum pipe size of 12-inch for inlet
structures and 15-inch for all other structures has been observed.
e. The stormwater conveyance system on site is designed to convey the
25-year storm event.
f. All inlets and manholes have a 9-inch sump for sediment collection
as shown on the Grading Plan.
4. The redevelopment project is greater than one acre and therefore will
infiltrate runoff generated from the first 0.5-inches of rainfall from a 24-hour
storm. This drainage report calls to infiltrate the entire 10-year, 2-hour storm
event. As part of the new road an outlet structure will be installed in the
infiltration basin to discharge runoff volumes above the 0.5-inch of rainfall.
B. Storm Drainage Plan
1. See the attached Figure 1 that shows the watershed delineation and area. See
grading plan in attached plan set for the complete drainage plan. Figure 2
shows a more detailed breakdown of the watersheds within Northwestern
Energy's property.
2. One-foot contours have been displayed on the Grading Plan of the
corresponding plan set.
3. The ultimate destination of the stormwater runoff from the five areas is the
East Gallatin River. It is not expected that the increased runoff from the new
road and site improvements will have negative impacts on the downstream
drainage facilities.
4. A summary of the results of the drainage calculations are provided below and
the detailed calculations are included in Appendix B.
V:17032_NwE_Storm_Drainage_Plan_101617_SC 3 (10/16/17)SN/jIl
5. A maintenance plan for the infiltration basins has been included in Appendix
C.
6. See grading, drainage and detail plan within the plan set for details and
specifications for all storm drainage improvements.
C. Storage/Treatment Facilities
As outlined in the geotechnical report attached, the boring closest to the infiltration
basin, B-6, shows poorly graded gravel with clay and sand at approximately 4.5 feet.
The bottom of the infiltration basin will key into these gravels and an infiltration rate
of 3.42 inches/hour which is the average infiltration rate between GP and GC soils.
The infiltration basin located in the northwest corner of NorthWestern Energy's
property provides 72,126 CF of storage. Based on the runoff calculations provided in
the appendix, the required storage volume needed is 47,187 CF.
The infiltration basin will have three outfalls, only one outfall will be constructed
under this project. Currently, there is an existing outfall structure that discharges
excess runoff from the pond to the pond within the East Gallatin Recreation Center,
as requested by the City, this outlet structure will be removed and the pond will be
given an alternative discharge point. Until the new road is constructed, runoff that
enters the pond will infiltrate, theoretically, the pond will completely infiltrate within
20 hours after the storm event. Runoff, from a storm event that produced over
72,126 CF of runoff, will overtop the pond and discharge into the pond within the
East Gallatin Recreation Center. When the new road is built, a discharge structure
will be constructed in the pond which will discharge water to the new roadside ditch
which will convey water to the existing swale located adjacent to the park. This swale
discharges water into the East Gallatin Recreation Center.
1. The proposed detention basin will be reconstructed within the existing
detention basin, and will utilize the existing basin as much as possible.
2. The new infiltration pond will have 4:1 side slopes and a depth of 5 feet,
however there is a fence around NorthWestern Energy's laydown yard where
the pond is located.
3. The infiltration basin is located on NorthWestern Energy's property in the
far northwest corner of the site.
4. Basin Characteristics
a. The proposed detention basin lengths are designed to be
approximately three times the width. The basin is 151 feet long and
57 feet wide. Inlet velocities to the basins will be dissipated with
riprap.
b. The proposed basin side slopes are designed to have a 4:1 side slope.
W7032_NWE_Storm_Drainage_Plan_101617_SC 4 (10/16/17)SN/j
C. Vegetated channels will be utilized to convey water for the new road,
details on the new road drainage will be given in the drainage report
for that project submittal.
d. The detention basins on site are not located in a floodplain.
e. Spill points and overflows have been designed around the site in
order to limit any potential flooding damage.
5. The rational method has been used to calculate all peak flows and retention
volumes. See Appendix B for detailed calculations on retention volumes.
D. Discharge Structure
1. A flared end section with a trash rack is used as a discharge structure to the
basin displayed in the City of Bozeman Standard Modification Storm Drain
Debris Rack No.02720-11. A manhole discharge structure will be installed
with the construction of the new road.
2. An orifice equation was not used for this stormwater management plan as no
complex discharge structure has been proposed.
3. Failsafe
a. Spill points have been designed around the site as emergency
overflows in the event of a design storm exceeding the 25-year storm
event.
b. The discharge pipe is a minimum of 12 inches in diameter
C. All stormwater systems onsite have been designed to avoid long-term
standing water. However, the infiltration basin will have no real
discharge structure until the completion of the new road so there is a
potential for standing water.
E. Runoff Estimation
1. The modified rational method was used to determine peak runoff rates.
a. It was assumed the rainfall is uniformly distributed over the area for
the entire duration of the storm. The rational formula provided in The
City of&Zenian Standard Specifications and Policy was used to calculate
the peak runoff rates on site. The rainfall intensity for the site was
calculated in part by using Figure I-2 and I-3.
b. The peak runoff rate occurs when the duration of the storm equals
the time of concentration. The provided time of concentration tools,
Table I-2, Table I-3 and Figure I-1, in The City of Bo�eman's Design
Standard and Specifications Policy were used to calculate the time of
concentration for each of the major watersheds.
C. The runoff coefficient for a particular watershed is constant for a
similar land use. The runoff coefficients provided in Table I-1 were
used in calculating the peak runoff rates.
V:17032_N%VE_Storm_Drainag(�_Plan_101617_SC 5 (10/16/'17)SN/jU
2. As mentioned above, runoff coefficients from Table I-1 were used to
calculate runoff rates for each of the watersheds.
3. As mentioned above, time of concentration was determined, as outlined in
The City of Bo:�e&lan Design Standards and Specfcatioil Policy, as a function of the
ground slope, roughness, and hydraulic radius. The time of concentration
included durations from sheet flow, shallow concentrated flow and channel
flow.
4. The stormwater system is designed to convey the peak flows from the 25-
year storm event. The infiltration basin has been designed for the 10-year, 2-
hour storm event.
F. Conveyance Facilities
All proposed drainage facilities have been designed to accommodate the 25-year
storm event. Please see sizing calculations included in the Appendix of this report for
additional information.
V:17032 NWE_Storm_Drainage_Plan_101617_SC 6 (10/16/17)SN/jil
APPENDIX A: WATERSHEDS
-
EAST SIT
O"
b
�4 3
- . 1 lb
i
P -
O
tw
. � 16
� e ♦ � Mr
Z _
a
,4
w
11
2 Y
s�- 3
8 4
APPENDIX B: CALCULATIONS
Table 1:Watershed Properties
Watershed Total Area(SF) Impervious Area Pervious Area Time of 25-year
(SF) (SF) Concentration Peak Runoff
1 27,909 25,131 2,778 10 min 1.44
2 13,686 13,504 182 10 min 0.76
3 13,918 1,745 12,173 10 min 0.25
4 20,579 11,724 8,855 5 min �1.04
5 14,26'1 11,385 2,876 5 min 1.05
6 4,935 4,397 538 5 min 0.39
7 2,612 2,602 10 5 min 0.03
.___... ....._...__.._...------...._._..___._, _ _.___._.___._...
8 30,608 15,617 14,991 5 min 1.G5
9 5,164 4,367 797 5 min 0.40
10 1,495 - 1,495 5 min 0.03
11 4,330 _._._.. _ 1,380 2,950 5 min 0.18
12 39,273 39,273 - 5 min 3.42
._......._..-_......................_......---....._..._................._..._........__._._...._...._...... --....
13 94,802 18,216 76,586 15 min 2.98
14 63,841 - 63,841 15 min 1.83.
_._._15--- - y38,231 - 38,231 15 min 1.10
16 212,405 39,706 172,699 15 min 6.67
Pond 22,770 22,770 5 min 1.23
.._...._._._......_.........
._....___..
Total 610,819
Project:Northwestern Energy Addition : i
Project#: 0 t
Date:10/16/2017 SANDERSONW50
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E A R T
Overall Watershed
Design Storm Frequency= 10 years
Infiltration
Unit Width(ft) Unit Length(ft) Rate Discharge
Rate(cfs)
(in/hr)
Discharge Rate,d= 0.68 cfs 57 151 3.42 0.6813875
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 felacre) C Cf C x Cf C' C'x A
Surface Type (ft') Acres =(C x C�<or=t Acres
Impervious 374705 8.60 0.9 1 0.90 0.90 7.741838843
Landscape 149568 3.43 0.2 1 020 0.20 0.686721763
Gravel 675954 15.52 0.6 1 0.60 0.60 9.310661157
0 1 0.00 0.00 0
0 1 0.00 0.00 0
Totals 1200227 275534 ]7.7392
Weighted Runoff Coefficient,Cwd SCiAi
_ - 0.6438 C,a x Cr= 0.64
SAi
C,d x Cfx SAi= 17.74
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =C-x SAi x i x t =d x t =Runoff Volumc-Discharge Volumc =C W x SAj x i
(min) (in/hr) (h3) (ft') (ft3) (ft3/S)
1 9.16 9751.34 40.88 9710.45 162.52
5 3.22 17127.88 204.42 16923.46 57.09
10 2.05 21830.52 408.83 21421.69 36.38
15 1.58 25159.15 613.25 24545.91 27.95
20 131 27824.32 817.67 27006.66 23.19
25 1.13 30084.52 1022.08 29062.44 20.06
30 1.00 32066.87 1226.50 30840.37 17.81
35 0.91 33844.49 1430.91 32413.57 16.12
40 0.83 35463.79 1635.33 33828.46 14.78
45 0.77 36956.30 1839.75 3511655 13.69
50 0.72 38344.55 2044.16 36300.38 12.78
55 0.68 39645.24 2248.58 37396.66 12.01
60 0.64 40871.17 2453.00 38418.17 11.35
75 0.55 44191.17 3066.24 41124.93 9.82
90 0.49 47103.04 3679.49 43423.55 8.72
105 0.44 49714.19 4292.74 45421.45 7.89
120 0.41 52092.78 4905.99 47186.79 7.24
150 0.35 56324.33 6132.49 50191.84 6.26
180 031 60035.69 7358.99 52676.70 5.56
360 0.20 76519.12 14717.97 61801.15 3.54
720 0.13 97528.26 29435.94 69092.32 2.26
1440 0.08 124305.68 58871.88
47,186.79 ft3 162.52 (ft3/s)
Project:Northwestern Energy Addition QVI-
RATIONAL �
Project#: 6/2 17 S A N D E R S O N Date:10/16/2017 METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 1
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 felacre) C Cf C X Cf Ct Ct X A
Surface Type (ft) Acres =(c x c�<or=1 Acres
Impervious 25131 0.58 0.9 1.1 0.99 0.99 0.571159091
Landscape 2778 0.06 0.2 1.1 0.22 0.22 0.014030303
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 27909 0.6407 NOW 0.5852
Weighted Runoff Coefficient,C«.d - SCiAi
- - 0.8303 C�„d x Cf= 0.91
SAi
CwdxCfxSAi= 0.59
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c.,x sA x i x t =(l3X t Runoff"Volume-Discharge Volume =cwd x sAj x i
(min) (in/hr) (ft3) (ft 1 (ft) (ft3/o
1 10.72 376.32 0.00 376.32 6.27
5 3.83 671.72 0.00 671.72 2.24
10 2.46 862.10 0.00 862.10 1.44
15 1.89 997.59 0.00 997.59 1.11
20 1.58 1106.45 0.00 1106.45 0.92
25 1.37 1199.00 0.00 1199.00 0.80
30 1.22 1280.33 0.00 1280.33 0.71
35 1.10 1353.39 0.00 1353.39 0.64
40 1.01 1420.04 0.00 1420.04 0.59
45 0.94 1481.55 0.00 1481.55 0.55
50 0.88 1538.82 0.00 1538.82 0.51
55 0.82 1592.54 0.00 1592.54 0.48
60 0.78 1643.21 0.00 1643.21 0.46
75 0.68 1780.66 0.00 1780.66 0.40
90 0.60 1901.46 0.00 1901.46 0.35
105 0.55 2009.96 0.00 2009.96 0.32
120 0.50 2108.94 0.00 2108.94 0.29
150 0.43 2285.35 0.00 2285.35 0.25
180 0.39 2440.38 0.00 2440.38 0.23
360 0.25 3132.05 0.00 3132.05 0.15
720 0.16 4019.75 0.00 4019.75 0.09
1440 0.10 5159.05 0.00
2,108.94 ft3 1.44 (£t3/s)
Project:Northwestern Energy Addition AM'
Project 11;1703 S A N D E R S O N W40
Date:10/16/2017 17
RATIONAL METHOD FOR RUNOFF CALCULATIONS T E A R T
Watershed 2
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 fJ/aorc) C C, C X C f C' C'X A
Surface Type (ft2) Acres =(c x ca<or=t Acres
Impervious 13504 0.31 0.9 1.1 0.99 0.99 0.306909091
Landscape 182 0.00 0.2 1.1 0.22 0.22 0.000919192
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 13686 0.3142 0.3078
Weighted Runoff Coefficient,C«.d SCIAi
_ = 0.8907 C'd x Cr= 0.98
SAI
C_l x Cr x SAI= 0.31
Where CI is the adjusted runoff coefficient for surface type j
is the area of surface type j and Ai
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c,,,x sA;x i x t =d x t =Runoff Volume-Discharge volume =Z x sAl x
(min) (in/hr) (ft) (ft) (ft) (ft'/s)
1 10.72 197.96 0.00 197.96 3.30
5 3.83 353.35 0.00 353.35 1.18
10 2.46 453.49 0.00 453.49 0.76
15 1_89 524.76 0.00 524.76 0.58
20 158 582.03 0.00 582.03 0.49
25 1.37 630.71 0.00 630.71 0.42
30 1.22 673.50 0.00 673.50 0.37
35 1.10 711.93 0.00 711.93 0.34
40 1.01 746.99 0.00 746.99 0.31
45 0.94 779.34 0.00 77934 0.29
50 0.88 809.47 0.00 809.47 0.27
55 0.82 837.73 0.00 837.73 0.25
60 0.78 864.38 0.00 86438 0.24
75 0.68 936.68 0.00 936.68 0.21
90 0.60 1000.23 0.00 1000.23 0.19
105 055 1057.30 0.00 1057.30 0.17
120 0.50 1109.37 0.00 1109.37 0.15
150 0.43 1202.16 0.00 1202.16 0.13
180 039 1283.72 0.00 1283.72 0.12
360 0.25 1647.56 0.00 1647.56 0.08
720 0.16 2114.52 0.00 2114.52 0.05
1440 0.10 2713.82 0.00
1,109.37 fe 0.76 (ft'/s)
Project:Northwestern Energy Addition QVIK
Project#: SANDERSON
Date:10/16/2017 017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E A R T
Watershed 3
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 felacre) C Cf C X C f C' C'X A
Surface Type (ft) Acres =(C x Co<or=r Acres
Impervious 1745 0.04 0.9 1.1 0.99 0.99 0.039659091
Landscape 12173 0.28 0.2 1.1 0.22 0.22 0.061479798
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 13918 0.3195 0.1011
Weighted Runoff Coefficient,Cwd - SCiAi -
- - 0.2878 Cwd x C f= 0.32
SAi
Cwd xCfxSAi= 0.10
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =Cvd x SA;x i x t =d X t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(rain) (in/hr) (ft3) (ft3) (ft3) (ft3/s)
1 10.72 65.04 0.00 65.04 1.08
5 3.83 116.09 0.00 116.09 0.39
10 2.46 149.00 0.00 149.00 0.25
15 1.89 172.41 0.00 172.41 0.19
20 1.58 191.23 0.00 191.23 0.16
25 1.37 207.22 0.00 207.22 0.14
30 1.22 221.28 0.00 22128 0.12
35 1.10 233.91 0.00 233.91 0.11
40 1.01 245.43 0.00 245.43 0.10
45 0.94 256.06 0.00 256.06 0.09
50 0.88 265.96 0.00 265.96 0.09
55 0.82 275.24 0.00 275.24 0.08
60 0.78 284.00 0.00 284.00 0.08
75 0.68 307.75 0.00 307.75 0.07
90 0.60 328.63 0.00 328.63 0.06
105 0.55 347.38 0.00 347.38 0.06
120 0.50 364.49 0.00 364.49 0.05
150 0.43 394.98 0.00 .394.98 0.04
180 0.39 421.77 0.00 421.77 0.04
360 0.25 541.31 0.00 541.31 0.03
720 0.16 694.74 0.00 694.74 0.02
1440 0.10 891.64 0.00
364.49 ft3 0.25 (ft3/s)
Project:Northwestern Energy Addition L �r
Project#:17032.0 S A N D E R S O N t '�
Date:10/16/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS GI E A
Watershed 4
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 fry/acre) C Cf C x Cf C' C'x A
Surface Type (ft) Acres =(C x C�<or=t Acres
Impervious 11724 0.27 0.9 1.1 0.99 0.99 0.266454545
Landscape 885 0.02 0.2 1.1 0.22 0.22 0.004469697
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 12609 0.2895-A 0.2709
Weighted Runoff Coefficient,C_1 SCii
- A - 0.8509 Cwd x Cf= 0.94
SAi
C,..d a Cfx SAi= 0.27
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface tape j
A=rrrz
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =C,�.sA x's t =d x t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(min) (in/hr) (ft) (ft3) (ft) (ft3/s)
1 10.72 174.23 0.00 174.23 2.90
5 3.83 310.99 0.00 310.99 1.04
10 2.46 399.13 0.00 399.13 0.67
15 1.89 461.85 0.00 461.85 0.51
20 1.58 512.25 0.00 512.25 0.43
25 1.37 555.10 0.00 555.10 0.37
30 1.22 592.75 0.00 592.75 0.33
35 1.10 626.58 0.00 626.58 0.30
40 1.01 657.43 0.00 657.43 0.27
45 0.94 685.91 0.00 685.91 0.25
50 0.88 712.43 0.00 712.43 0.24
55 0.82 737.29 0.00 737.29 0.22
60 0.78 760.76 0.00 760.76 0.21
75 0.68 824.39 0.00 824.39 0.18
90 0.60 880.31 0.00 880.31 0.16
105 0.55 930.55 0.00 930.55 0.15
120 0.50 976.37 0.00 976.37 0.14
150 0.43 1058.04 0.00 1058.04 0.12
180 0.39 1129.82 0.00 1129.82 0.10
360 0.25 1450.04 0.00 1450.04 0.07
720 0.16 1861.02 0.00 1861.02 0.04
1440 0.10 2388.48 0.00
976.37 ft3 1.04 (ft3/s)
Project:Northwestern Energy Addition t�'
Project#h 17032.0 SANDERS O N �IA
Date:10/16/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 5
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ft'/acre) C Cf C X C f Ct Ct X A
Surface Type (fr) Acres =(C x Q<or=t Acres
Impervious 11385 0.26 0.9 1.1 0.99 0.99 0.25875
Landscape 2876 0.07 0.2 1.1 0.22 0.22 0.014525253
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 14261 0.3274 0.2733
Weighted Runoff Coefficient,C,d - SCiAi -
-
SAi 0.7588 Cwd x C f= 0.83
Cwd x Cfx SAi= 0.27
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c,'x sA x i x t =d X t =Runoff Volume-Discharge Volumc =Cwd x SAj x i
(min) (tn/hr) (0 (0 (ft3) (ft3/s)
1 10.72 175.74 0.00 175.74 2.93
5 3.83 313.68 0.00 313.68 1.05
10 2.46 402.59 0.00 402.59 0.67
15 1.89 465.86 0.00 465.86 0.52
20 1.58 516.69 0.00 516.69 0.43
25 1.37 559.91 0.00 559.91 0.37
30 1.22 597.90 0.00 597.90 0.33
35 1.10 632.02 0.00 632.02 0.30
40 1.01 663.14 0.00 663.14 0.28
45 0.94 691.86 0.00 691.86 0.26
50 0.88 718.61 0.00 718.61 0.24
55 0.82 743.69 0.00 743.69 0.23
60 0.78 767.36 0.00 767.36 0.21
75 0.68 831.54 0.00 831.54 0.18
90 0.60 887.95 0.00 887.95 0.16
105 0.55 938.62 0.00 938.62 0.15
120 0.50 984.85 0.00 984.85 0.14
150 0.43 1067.22 0.00 1067.22 0.12
180 039 1139.62 0.00 1139.62 0.11
360 0.25 1462.62 0.00 1462.62 0.07
720 0.16 1877.17 0.00 1877.17 0.04
1440 0.10 2409.20 0.00
984.85 ft3 1.05 (ft3/s)
Project:Northwestern Energy Addition AM
Project#: 0 S A N D E R S O N AF
Date:10/16/2016/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS T E WA R T
Watershed 6
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 fry/acre) C Cf C X C f C' C'X A
Surface Type (ft) Acres =(C x Ca<or=1 Acres
Impervious 4397 0.10 0.9 1.1 0.99 0.99 0.099931818
Landscape 538 0.01 0.2 1.1 0.22 0.22 0.002717172
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 4935 0.1133 EMU 0.1026
Weighted Runoff Coefficient,C«.d SCiAi
_ - 0.8237 C,d x Cf= 0.91
SAi
C,.d x CI x SAi= 0.10
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=rrr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =CWd x SA,x'x t =d3x t =Runoff Volume-Discharge Volumc =C vd x SAj x i
(min) (in/hr) (ft) (ft) (fr3) (ft3/s)
1 10.72 66.01 0.00 66.01 1.10
5 3.83 117.83 0.00 117.83 0.39
10 2.46 151.22 0.00 151.22 0.25
15 1.89 174.99 0.00 174.99 0.19
20 158 194.08 0.00 194.08 0.16
25 1.37 210.32 0.00 210.32 0.14
30 1.22 224.59 0.00 224.59 0.12
35 1.10 237.40 0.00 237.40 0.11
40 1.01 249.09 0.00 249.09 0.10
45 0.94 259.88 0.00 259.88 0.10
50 0.88 269.93 0.00 269.93 0.09
55 0.82 279.35 0.00 279.35 0.08
60 0.78 288.24 0.00 288.24 0.08
75 0.68 312.35 0.00 312.35 0.07
90 0.60 333.54 0.00 333.54 0.06
105 055 352.57 0.00 352.57 0.06
120 0.50 369.93 0.00 369.93 0.05
150 0.43 400.88 0.00 400.88 0.04
180 0.39 428.07 0.00 428.07 0.04
360 0.25 549.40 0.00 549.40 0.03
720 0.16 705.11 0.00 705.11 0.02
1440 0.10 904.96 0.00
369.93 ft3 0.39 (ft3/s)
Project:Northwestern Energy Addition
Project :0 S A N D E R S O N t III
Date:10/16/2016/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E A R T
Watershed 7
Design Storm Frequency= 25 years
Discharge Rate,d= OCfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560£?here) C Cf C x C f C' C'x A
Surface Type (ft) Acres =(C x CO<or=t Acres
Impervious 10 0.00 0.9 1.1 0.99 0.99 0.000227273
Landscape 1602 0.04 0.2 1.1 0.22 0.22 0.008090909
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 1612 0.0370 0.0083
Weighted Runoff Coefficient,Cwd - SCiAi -
- 0.2043 Cwd x CF= 0.22
SAi
C«,d x CF x SAi= 0.01
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c,.�x sn x i x t =d x t =Runoff Volume-Discharge Volume =Cwd x SAj x i
( ) (in/hr) (ft) (0 (ft) (ft3/s)
1 10.72 5.35 0.00 5.35 0.09
5 3.83 9.55 0.00 9.55 0.03
10 2.46 12.25 0.00 12.25 0.02
15 1.89 14.18 0.00 14.18 0.02
20 1.58 15.73 0.00 15.73 0.01
25 1.37 17.04 0.00 17.04 0.01
30 1.22 18.20 0.00 18.20 0.01
35 1.10 19.24 0.00 19.24 0.01
40 1.01 20.19 0.00 20.19 0.01
45 0.94 21.06 0.00 21.06 0.01
50 0.88 21.87 0.00 21.87 0.01
55 0.82 22.64 0.00 22.64 0.01
60 0.78 23.36 0.00 23.36 0.01
75 0.68 25.31 0.00 2531 0.01
90 0.60 27.03 0.00 27.03 0.01
105 0.55 28.57 0.00 28.57 0.00
120 0.50 29.98 0.00 29.98 0.00
150 0.43 32.49 0.00 32.49 0.00
180 039 34.69 0.00 34.69 0.00
360 0.25 44.52 0.00 44.52 0.00
720 0.16 57.14 0.00 57.14 0.00
1440 0.10 73.33 0.00
29.98 ft3 0.03 (ft3/s)
Project:Northwestern Energy Addition
Project#: 0
Date:10/16/2016/2017 S A N D E R S O N t'10
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E A R T
Watershed 8
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ftr/acrc) C CC C x C f C' C'x A
Surface Type (ft) Acres =(c x cr)<or=t Acres
Impervious 15617 0.36 0.9 1.1 0.99 0.99 0.354931818
Landscape 14991 0.34 0.2 1.1 0.22 0.22 0.075712121
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 30608 0.7027 0.4366
Weighted Runoff Coefficient,C,,.d SCiAi -
_ - 0.5572 C,d x CC= 0.61
SAi
C,,d x CC x SAj= 0.43
Where Ci is the adjusted runoff coefficient for surface type f
and Ai is the area of surface type j
A =rrr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =Cod x st;x i x t =d x t =Runoff Volume-Discharge Volumc =Cwd x SAj x i
(min) (113/hr) (ft) (ft3) (ft3) (ft3/S)
1 10.72 276.94 0.00 276.94 4.62
5 3.83 494.32 0.00 494.32 1.65
10 2.46 634.43 0.00 634.43 1.06
15 1.89 734.13 0.00 734.13 0.82
20 1.58 814.24 0.00 814.24 0.68
25 1.37 882.35 0.00 882.35 0.59
30 1.22 942.20 0.00 942.20 0.52
35 1.10 995.97 0.00 995.97 0.47
40 1.01 1045.02 0.00 1045.02 0.44
45 0.94 1090.28 0.00 1090.28 0.40
50 0.88 1132.43 0.00 1132.43 0.38
55 0.82 1171.96 0.00 1171.96 0.36
60 0.78 1209.25 0.00 1209.25 0.34
75 0.68 1310.40 0.00 1310.40 0.29
90 0.60 1399.29 0.00 1399.29 0.26
105 0.55 1479.14 0.00 1479.14 0.23
120 050 1551.98 0.00 1551.98 0.22
150 0.43 1681.80 0.00 1681.80 0.19
180 0.39 1795.89 0.00 1795.89 0.17
360 0.25 2304.89 0.00 2304.89 0.11
720 0.16 2958.15 0.00 2958.15 0.07
1440 0.10 3796.57 0.00
1,551.98 ft3 1.65 (ft3/s)
Project:Northwestern Energy Addition 40M
Project#: S A N D E R S O N 400
Date:10/16/2017 017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 9
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 fJ/acre) C Cf C x Cf C' C'x A
Surface Type (fr2) Acres =(c x c�<or=t Acres
Impervious 4367 0.10 0.9 1.1 0.99 0.99 0.09925
Landscape 797 0.02 0.2 1.1 0.22 0.22 0.004025253
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 5164 0.1185 MESON 0.1033
Weighted Runoff Coefficient,C,..d - SCiAI SAi -
0.7920 Cwd x C f= 0.87
C«.d x Cfx SAI= 0.10
Where Cl is the adjusted runoff coefficient for surface type j
and AI is the area of surface type j
A=rrrz
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =CWd x sA x i x t =d x t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(-in) (in/hr) (ff) (ft3) (ft3) (ft3/S)
1 10.72 66.41 0.00 66.41 1.11
5 3.83 118.55 0.00 118.55 0.40
10 2.46 152.15 0.00 152.15 0.25
15 1.89 176.06 0.00 176.06 0.20
20 1.58 195.27 0.00 195.27 0.16
25 1.37 211.60 0.00 211.60 0.14
30 1.22 225.96 0.00 225.96 0.13
35 1.10 238.85 0.00 238.85 0.11
40 1.01 250.61 0.00 250.61 0.10
45 0.94 261.47 0.00 261.47 0.10
50 0.88 271.57 0.00 271.57 0.09
55 O.S2 281.05 0.00 281.05 0.09
60 0.78 290.00 0.00 290.00 0.08
75 0.68 314.25 0.00 314.25 0.07
90 0.60 335.57 0.00 335.57 0.06
105 0.55 354.72 0.00 354.72 0.06
120 0.50 372.19 0.00 372.19 0.05
150 0.43 403.32 0.00 40332 0.04
180 0.39 430.68 0.00 430.68 0.04
360 0.25 552.75 0.00 552.75 0.03
720 0.16 709.41 0.00 709.41 0.02
1440 0.10 910.48 0.00
372.19 ft3 0.40 (ft3/s)
Project:Northwestern Energy Addition : �j
Project#: 0
Date:10/16/2017 SANDERSONW40 RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 10
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ft,/acre) C Cf C x C f C' C'x A
Surface Type (ft) Acres =(c x CO<or=t Acres
Impervious 0 0.00 0.9 1.1 0.99 0.99 0
Landscape 1495 0.03 0.2 1.1 0.22 0.22 0.007550505
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 1495 0.0343 0.0076
Weighted Runoff Coefficient,C«.d SCiAi
_ - 0.2000 C,d x Cf= 0.22
SAi
C_1xCfxSAi= 0.01
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=rrr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c,,x SAi x i x t =d X t =Runoff Volumc-Discharge Volumc =Cwd x SAj x i
(min) (tn/hr) (ft3) (ft3)
1 10.72 4.86 0.00 4.86 0.08
5 3.83 8.67 0.00 8.67 0.03
10 2.46 11.12 0.00 11.12 0.02
15 1.89 12.87 0.00 12.87 0.01
20 1.58 14.28 0.00 14.28 0.01
25 137 15.47 0.00 15.47 0.01
30 1.22 16.52 0.00 1652 0.01
35 1.10 17.46 0.00 17.46 0.01
40 1.01 18.32 0.00 18.32 0.01
45 0.94 19.12 0.00 19.12 0.01
50 0.88 19.85 0.00 19.85 0.01
55 0.82 20.55 0.00 20.55 0.01
60 0.78 21.20 0.00 21.20 0.01
75 0.68 22.98 0.00 22.98 0.01
90 0.60 24.53 0.00 24.53 0.00
105 0.55 25.93 0.00 25.93 0.00
120 0.50 27.21 0.00 27.21 0.00
150 0.43 29.49 0.00 29.49 0.00
180 0.39 31.49 0.00 31.49 0.00
360 0.25 40.41 0.00 40.41 0.00
720 0.16 51.87 0.00 51.87 0.00
1440 0.10 66.57 0.00
27.21 ft3 0.03 (ft3/s)
Project:Northwestern Energy Addition 40-W-2
Project#: S A N D E R S O N wip
Date:10/16/2017 6/2
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 11
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ftr/acre) C Cf C X Cf Ct Ct X A
Surface Type (fr) Acres =(c x Co<or=t Acres
Impervious 1380 0.03 0.9 1.1 0.99 0.99 0.031363636
Landscape 2950 0.07 0.2 1.1 0.22 0.22 0.01489899
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 4330 0.0994 0.0463
Weighted Runoff Coefficient,C,d SCiAi -
- - 0.4231 Cwd x Cf= 0.47
SAi
C,d x Cc x SAi= 0.05
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rrz
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =C.,x s,;x i x t =d X t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(min)( ) (m/hr) (ft) (0 (fi) (ft3/o
1 10.72 29.75 0.00 29.75 0.50
5 3.83 53.10 0.00 53.10 0.18
10 2.46 68.15 0.00 68.15 0.11
15 1.89 78.87 0.00 78.87 0.09
20 1.58 87.47 0.00 87.47 0.07
25 1.37 94.79 0.00 94.79 0.06
30 1.22 101.22 0.00 101.22 0.06
35 1.10 106.99 0.00 106.99 0.05
40 1.01 112.26 0.00 112.26 0.05
45 0.94 117.12 0.00 117.12 0.04
50 0.88 121.65 0.00 121.65 0.04
55 0.82 125.90 0.00 125.90 0.04
60 0.78 129.91 0.00 129.91 0.04
75 0.68 140.77 0.00 140.77 0.03
90 0.60 150.32 0.00 150.32 0.03
105 0.55 158.90 0.00 158.90 0.03
120 0.50 166.72 0.00 166.72 0.02
150 0.43 180.67 0.00 180.67 0.02
180 0.39 192.93 0.00 192.93 0.02
360 0.25 247.61 0.00 247.61 0.01
720 0.16 317.78 0.00 317.78 0.01
1440 0.10 407.85 0.00
166.72 ft3 0.18 (ft3/s)
Project:Northwestern Energy Addition 0�r
Project 0 S A N D E R S O N W49
Date:10/16/2016/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS
g E ART
Watershed 12
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 f?/acre) C Cf C X Cf Ct Ct X A
Surface Type (ft) Acres =(C x C�<of=t Acres
Impervious 39273 0.90 0.9 1.1 0.99 0.99 0.892568182
Landscape 0 0.00 0.2 1.1 0.22 0.22 0
Gravel 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 39273 0.9016 0.8926
Weighted Runoff Coefficient,C,,.d SCiAI -
_ - 0.9000 C,�d s Cf= 0.99
SAi
C,,.d x Cc SAi= 0.89
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=rrrZ
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c x sn x i x t =d X t =Runoff Volume-Discharge Volume =Cwd x SAi x i
(min) (in/hr) (ft3) (ft) (ft3)
1 10.72 573.99 0.00 573.99 9.57
5 3.83 1024.55 0.00 1024.55 3.42
10 2.46 1314.93 0.00 1314.93 2.19
15 1.89 1521.59 0.00 1521.59 1.69
20 1.58 1687.62 0.00 1687.62 1.41
25 1.37 1828.78 0.00 1828.78 1.22
30 1.22 1952.84 0.00 1952.84 1.08
35 1.10 2064.28 0.00 2064.28 0.98
40 1.01 2165.94 0.00 2165.94 0.90
45 0.94 2259.75 0.00 2259.75 0.84
50 0.88 2347.11 0.00 2347.11 0.78
55 0.82 2429.04 0.00 2429.04 0.74
60 0.78 2506.33 0.00 2506.33 0.70
75 0.68 2715.98 0.00 2715.99 0.60
90 0.60 2900.22 0.00 2900.22 0.54
105 0.55 3065.72 0.00 3065.72 0.49
120 0.50 3216.69 0.00 3216.69 0.45
150 0.43 3485.76 0.00 3485.76 0.39
180 0.39 3722.22 0.00 3722.22 0.34
360 0.25 4777.19 0.00 4777.19 0.22
720 0.16 6131.18 0.00 6131.18 0.14
1440 0.10 7868.91 0.00
3,216.69 ft3 3.42 (ft3/s)
Project:Northwestern Energy Addition duo
Project#:17032.0 SANDERS O N Q14
Date:10/16/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 13
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 felacre) C Cf C x C f C' C'x A
Surface Type (ft) Acres =(c x c�<or=t Acres
Impervious 18216 0.42 0.9 1.1 0.99 0.99 0.414
Landscape 0 0.00 0.2 1.1 0.22 0.22 0
Gravel 76586 1.76 0.6 1.1 R66 0.66 1.160393939
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 94802 2.1764 1.5744
Weighted Runoff Coefficient,C va - SCiAi
- - 0.6576 C,a x Cf= 0.72
SAi
C,,a x Cfx SAi= 1.57
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=Trr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t In/tensity,i =cq,x sM x'x r =d x t =is �offvomme-nischargc von e =cwa/x sA1 x
(lllltl) ( / ) (fr3) (ft3) (fi3) (ft3/S)
1 10.72 1012.46 0.00 1012.46 16.87
5 3.83 1807.20 0.00 1807.20 6.02
10 2.46 2319.40 0.00 2319.40 3.87
15 1.89 2683.92 0.00 2683.92 2.98
20 1_58 2976.78 0.00 2976.78 2.48
25 1.37 3225.78 0.00 3225.78 2.15
30 1.22 3444.61 0.00 3444.61 1.91
35 1.10 3641.17 0.00 3641.17 1.73
40 1.01 3820.48 0.00 3820.48 1.59
45 0.94 3985.96 0.00 3985.96 1.48
50 0.88 4140.05 0.00 4140.05 1.38
55 0.82 4284.56 0.00 4284.56 1.30
60 0.78 4420.90 0.00 4420.90 1.23
75 0.68 4790.69 0.00 4790.69 1.06
90 0.60 5115.68 0.00 5115.68 0.95
105 0.55 5407.60 0.00 5407.60 0.86
120 0.50 5673.90 0.00 5673.90 0.79
150 0.43 6148.50 0.00 6148.50 0.68
180 039 6565.60 0.00 6565.60 0.61
360 0.25 8426.46 0.00 8426.46 0.39
720 0.16 10814.73 0.00 10814.73 1 0.25
1440 0.10 13879.91 0.00
5,673.90 ft3 2.98 (ft3/s)
Project:Northwestern Energy Addition
AW2-
Projectt: 0
Date:10/16/2017 SANDERSON tP
_RATIONAL METHOD FOR RUNOFF CALCULATIONS t/�� '�
Watershed 14
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values For runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 felacre) C Cf C X Cf C' C'X A
Surface Type (ft) Acres =(C x c,)<or=i Acres
Impervious 0 0.00 0.9 1.1 0.99 0.99 0
Landscape 0 0.00 0.2 1.1 0.22 0.22 0
Gravel 63841 1.47 0.6 1.1 0.66 0.66 0.967287879
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 63841 1.4656 MEN 0.9673
Weighted Runoff Coefficient,Cwd SCir1i -
_ - 0.6000 C,d X CC= 0.66
SAi
C_1 x CC SAi= 0.97
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=Rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t In/tensity,i =c.�/x SAj x i x t -d X t =Runoff Volum/c-Discharge Volume =Cwd x SAj x i
(min) (lri/hr) (ft3) (ft3) (ft3) (ft3/S)
1 10.72 622.04 0.00 622.04 10.37
5 3.83 1110.32 0.00 1110.32 3.70
10 2.46 1425.01 0.00 1425.01 2.38
15 1.89 1648.96 0.00 1648.96 1.83
20 1.58 1828.90 0.00 1828.90 1.52
25 1.37 1981.88 0.00 1981.88 1.32
30 1.22 2116.32 0.00 2116.32 1.18
35 1.10 2237.09 0.00 2237.09 1.07
40 1.01 2347.25 0.00 2347.25 0.98
45 0.94 2448.92 0.00 2448.92 0.91
50 0.88 2543.59 0.00 2543.59 0.85
55 0.82 2632.38 0.00 2632.38 0.80
60 0.78 2716.14 0.00 2716.14 0.75
75 0.68 2943.34 0.00 2943.34 0.65
90 0.60 3143.01 0.00 3143.01 0.58
105 055 3322.36 0.00 3322.36 0.53
120 050 3485.97 0.00 3485.97 0.48
150 0.43 3777.56 0.00 3777.56 0.42
180 0.39 4033.82 0.00 4033.82 0.37
360 0.25 5177.11 0.00 5177.11 0.24
720 0.16 6644.44 0.00 6644.44 0.15
1440 0.10 8527.64 0.00
3,485.97 ft3 1.83 (ft3/s)
Project:Northwestern Energy Addition 40°
Project#: S A N D E R S O N 41F
Date:10/16/2017 017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Watershed 15
Design Storm Frequency= 25 years
Discharge Rate,d= Ocfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 fr'/acre) C Cf C X Cf C' C'X A
Surface Type (ft) Acres =(c x C�<or=t Acres
Impervious 0 0.00 0.9 1.1 0.99 0.99 0
Landscape 0 0.00 0.2 1.1 0.22 0.22 0
Gravel 38231 0.88 0.6 1.1 0.66 0.66 0.579257576
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 38231 0.8777 0.5793
Weighted Runoff Coefficient,C«.d - SCIAI -
- - 0.6000 Cwd x Cf= 0.66
SAI
Cwd x Cfx SAI= 0.58
Where CI is the adjusted runoff coefficient for surface type j
and AI is the area of surface type j
A=rrr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =c„,x SA;x i x t =d X t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(fin) (in/hr) (fr) (ft) (fr3) (ft3/S)
1 10.72 372.51 0.00 372.51 6.21
5 3.83 664.91 0.00 664.91 2.22
10 2.46 853.36 0.00 853.36 1.42
15 1.89 987.48 0.00 987.48 1.10
20 1.58 1095.23 0.00 1095.23 0.91
25 1.37 1186.84 0.00 1186.84 0.79
30 1.22 1267.35 0.00 1267.35 0.70
35 1.10 1339.67 0.00 1339.67 0.64
40 1.01 1405.65 0.00 1405.65 0.59
45 0.94 1466.53 0.00 1466.53 0.54
50 0.88 1523.22 0.00 1523.22 0.51
55 0.82 1576.39 0.00 1576.39 0.48
60 0.78 1626.56 0.00 1626.56 0.45
75 0.68 1762.61 0.00 1762.61 0.39
90 0.60 1882.18 0.00 1882.18 0.35
105 0.55 1989.59 0.00 1989.59 0.32
120 0.50 2087.56 0.00 20S7.56 0.29
150 0.43 2262.18 0.00 2262.18 0.25
180 0.39 2415.64 0.00 2415.64 0.22
360 0.25 3100.30 0.00 3100.30 0.14
720 0.16 3979.00 0.00 3979.00 0.09
1440 0.10 5106.75 0.00
23087.56 ft3 1.10 (ft3/s)
Project:Northwestern Energy Addition Lo"M
Project q:17032.0 S A N D E R S O N t '�
Date:10/16/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T EWART
Watershed 16
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ft,/acre) C Cf C X C f Ct Ct X A
Surface Type (ft) Acres =(C x C�<or=1 Acres
Impervious 39706 0.91 0.9 1.1 0.99 0.99 0.902409091
Landscape 0 0.00 0.2 1.1 0.22 0.22 0
Gravel 172699 3.96 0.6 1.1 0.66 0.66 2.616651515
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 212405 4.8761 3.5191
Weighted Runoff Coefficient,Cwd SCiAi
_ - 0.6561 Cwd X Cr= 0.72
SAi
Cwd X Cf X SAi= 3.52
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=lrr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,1 =C,,,x SAj x i x t =d X t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(min) (in/hr) (ft3) (ft3) (0 (ft3/s)
1 10.72 2263.03 0.00 2263.03 37.72
5 3.83 4039.42 0.00 4039.42 13.46
10 2.46 5184.29 0.00 5184.29 8.64
15 1.89 5999.05 0.00 5999.05 6.67
20 1.58 6653.65 0.00 6653.65 5.54
25 1.37 7210.21 0.00 7210.21 4.81
30 1.22 7699.33 0.00 7699.33 4.28
35 1.10 8138.68 0.00 8138.68 3.88
40 1.01 8539.47 0.00 8539.47 3.56
45 0.94 8909.35 0.00 8909.35 3.30
50 0.88 9253.77 0.00 9253.77 3.08
55 0.82 9576.79 0.00 9576.79 2.90
60 0.78 9881.52 0.00 9881.52 2.74
75 0.68 10708.08 0.00 10708.08 2.38
90 0.60 11434.49 0.00 11434.49 2.12
105 0.55 12086.97 0.00 12086.97 1.92
120 0.50 12682.20 0.00 12682.20 1.76
150 0.43 13743.02 0.00 13743.02 1.53
180 0.39 14675.32 0.00 14675.32 1.36
360 0.25 18834.68 0.00 18834.68 0.87
720 0.16 24172.92 0.00 24172.92 0.56
1440 0.10 31024.15 0.00
3
12,682.20 ft 6.67 (ft3/s)
Project:Northwestern Energy Addition tom%
Project##:17032.0 SANDERS O N MM
Date:10/16/2017
RATIONAL METHOD FOR RUNOFF CALCULATIONS S T E WA R T
Pond
Design Storm Frequency= 25 years
Discharge Rate,d= �cfs
Input values for runoff coefficients from appropriate tables.
Runoff Frequency Calculation
Area Area Coefficient Factor Value
A A/(43560 ft'/acre) C Cf C x C f C' C'x A
Surface Type (ftZ) Acres =(C x C�<er=1 Acres
Impervious 0 0.00 0.9 1.1 0.99 0.99 0
Landscape 22770 0.52 0.2 1.1 0.22 0.22 0.115
Gravel 0 0.00 0.6 1.1 0.66 0.66 0
0 1.1 0.00 0.00 0
0 1.1 0.00 0.00 0
Totals 22770 0.5227 0.1150
Weighted Runoff Coefficient,Cud - SCiAI -
0.2000 Cw d x Cf= 0.22
SAS
Cwd x Cfx SA = 0.12
Where Ci is the adjusted runoff coefficient for surface type j
and Ai is the area of surface type j
A=7rr2
Rainfall Rainfall Runoff Volume Discharge Volume Site Detention Peak Flow
Duration,t Intensity,i =C_x SA,x i x t =d3x�t =Runoff Volume-Discharge Volume =Cwd x SAj x i
(min) (tn/hr) (ft3) (ft J (ft) (ft3/s)
1 10.72 73.95 0.00 73.95 1.23
5 3.83 132.00 0.00 132.00 0.44
10 2.46 169.42 0.00 169.42 0.28
15 1.89 196.04 0.00 196.04 0.22
20 1.58 217.44 0.00 217.44 0.18
25 1.37 235.62 0.00 235.62 0.16
30 1.22 251.61 0.00 251.61 0.14
35 1.10 265.97 0.00 265.97 0.13
40 1.01 279.06 0.00 279.06 0.12
45 0.94 291.15 0.00 291.15 0.11
50 0.88 302.41 0.00 302.41 0.10
55 0.82 312.96 0.00 312.96 0.09
60 0.78 322.92 0.00 322.92 0.09
75 0.68 349.93 0.00 349.93 0.08
90 0.60 373.67 0.00 373.67 0.07
105 0.55 394.99 0.00 394.99 0.06
120 0.50 414.44 0.00 414.44 0.06
150 0.43 4-49.11 0.00 449.11 0.05
180 0.39 479.58 0.00 479.58 0.04
360 0.25 615.50 0.00 615.50 0.03
720 0.16 789.95 0.00 789.95 0.02
1440 0.10 1013.84 0.00
414.44 ft3 1.23 (ft3/5)
Project:Northwestern Energy Addition
Project#:17032.0
Date:10/16/2017
TABLE 1-1:Runoff Coefficients for Use in the Rational Method
LAND USE RUNOFF COEFFICIENTS,C
Open Land 0.2
Low to Medium Density Residential 0.35
Dense Residential 0.5
Commercial Neighborhood 0.6
Commercial Downtown 0.8
Industrial 0.8
Project:Northwestern Energy Addition
Project#i:17032.0
Date:10/16/2017
Design Standards and Specifications Policy
City of Bozeman,March 2004 as Amended
RAINFALL INTENSITY-DURATION CURVES(Figures 1-2,1-3)
Storm Recurrence Interval
Time 2 5 10 ZS 54 100
(min) (in/hr) (in/hr) (in/hr) (in/hr) (i"r) (in/hr)
1 4.20 7.15 9.16 10.72 13.72 15.69
5 1.60 2.55 3.22 3.83 4.74 5.34
10 1.05 1.64 2.05 2.46 3.00 3.35
15 0.83 1.26 1.58 1.89 2.30 2.56
20 0.70 1.05 1.31 1.58 1.90 2.11
25 0.61 0.91 1.13 1.37 1.64 1.82
30 0.55 0.81 1.00 1.22 j 1.45 1.61
35 0.50 0.73 0.91 1.10 1.31 1.45
40 0.46 0.67 0.83 1.01 1.20 1.33
45 0.43 0.63 0.77 0.94 1.11 1.22
50 0.40 0.58 0.72 0.88 1.04 1.14
55 0.38 0.55 0.68 0.82 0.97 1.07
60 0.36 0.52 0.64 1 0.78 0.92 1.01
75 0.31 0.45 0.55 0.68 0.79 0.87
90 0.28 0.40 0.49 0.60 0.70 0.77
105 0.26 0.36 0.44 0.55 0.64 0.69
120 0.24 0.33 0.41 0.50 0.58 0.63
150 0.21 0.29 0.35 0.43 0.50 0.55
180 0.19 0.26 0.31 0.39 0.45 0.48
360 0.12 0.17 0.20 0.25 0.28 0.30
720 0.08 0.11 0.13 0.16 0.18 0.19
1440 1 0.05 0.07 0.08 0.10 0.11 0.12
Project:Northwestern Energy Addition
Project#:17032.0
Date:10/16/2017
Design Standards and Specifications Policy
City of Bozeman, March 2004 as Amended
Zoning District/Design Storm Requirement
Design Rainfall
Zoning i a Frequency
Open Land 2-year
Residential 10-year
Commercial 10-year
(p.28,Table I-3)
Project:Northwestern Energy Addition
Project#:17032.0
Date:10/16/2017
STORMWATER MANAGEMENT MANUAL
TABLE 2-5 FREQUENCY FACTORS FOR THE RATIONAL FORMULA
Recurrence Interval Adjustment Factor !.
(Years) Cf
2 1.00
5 1.00
10 1.00
25 1.10
50 1.20
100 1.25
*C X Crshould not exceed 1.0
S,, m Drain Pipe Flow
Watershed 1 Inlet
Qin 1.44 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 1.815 cfs Flow Capacity
Watershed 2 Inlet
Qin 2.2 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 15 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 3.291 cfs Flow Capacity
Watershed 3 Inlet
Qin 2.45 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 15 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 3.291 cfs Flow Capacity
Watershed 4 Inlet
Qin 3.49 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 15 inches Pipe Diameter
S 0.0026 ft/ft Pipe Slope
Q 3.578 cfs Flow Capacity (75% full)
Watershed 6,7, 9 & 10 Inlet
Qin 0.85 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 1.815 cfs Flow Capacity
Watershed 8 Inlet
Qin 1.65 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 1.815 cfs Flow Capacity
Watershed 5 Inlet
Qin 2.7 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 15 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 3.291 cfs Flow Capacity
Manhole
Qin 7.04 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 18 inches Pipe Diameter
S 0.005 ft/ft Pipe Slope
Q 8.068 cfs Flow Capacity
Watershed 11 Inlet
Qin 7.22 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 18 inches Pipe Diameter
S 0.005 ft/f Pipe Slope
Q 8.068 cfs Flow Capacity
Watershed 13 Inlet
Qin 2.98 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.006 ft/ft Pipe Slope
Q 2.998 cfs Flow Capacity
Manhole
Qin 10.2 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 18 inches Pipe Diameter
S 0.0086 ft/ft Pipe Slope
Q 10.582 cfs Flow Capacity
Watershed 14 Inlet
Qin 1.83 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.003 ft/ft Pipe Slope
Q 2.120 cfs Flow Capacity
Manhole
Qin 12.03 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 24 inches Pipe Diameter
S 0.0086 ft/ft Pipe Slope
Q 22.789 cfs Flow Capacity
Watershed 15 Inlet
Qin 1.1 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 12 inches Pipe Diameter
S 0.0022 ft/ft Pipe Slope
Q 1.815 cfs Flow Capacity
Outfall
Qin 13.13 cfs
n 0.012 RCP Mannings Roughness Coefficient
d 24 inches Pipe Diameter
S 0.005 ft/ft Pipe Slope
Q 17.376 cfs Flow Capacity
APPENDIX C: MAINTENANCE PLAN
SANDERSON V
STEWART
October 17, 2017
Project No. 17032
STORM DRAINAGE FACILITY MAINTENANCE PLAN
FOR
NORTHWESTERN ENERGY BUILDING ADDITION
BOZEMAN, MONTANA
OVERVIEW NARRATIVE
The purpose of this maintenance plan is to outline the necessary details needed to determine who is
responsible for the maintenance of the facilities, when the facilities need to be maintained and who
owns the storm drainage facilities. The City of Bo.Zeman Design Standards and Specifications Policy, dated
March 2004. The site stormwater improvements have been designed with the intent to meet the
current City of Bozeman drainage regulations for the entire site to the extent feasible.
Specific site information and criteria are described below:
I. Ownership of all facilities
Northwestern Energy
II. Schedule:
Infiltration Basin:
Inspection: Every 6 months
Dredge Pond: Every 2 years or as needed based on inspection
Inlets &Manholes:
Inspection: Every 6 months
Vacuum: Every 2 years or as needed based on inspection
III. Responsible Party:
Northwestern Energy
rtHO FIRM To Plan and Design
-_� Enduring Communities...
www.sa ndersonstewa rt. com
APPENDIX D: GEOTECH REPORT
Project No.:4531.12044.01 LOG OF BOREHOLE B-6 Sheet 1 of 1
CLIENT PROJECT
NorthWestern Energy Bozeman Service Center Expansion
BORING LOCATION SITE
Pro osed Access Road-See Fi ure 2 Bozeman Montana
SAMPLES TESTS
M.C.
o wU
MATERIAL DESCRIPTION J Z L w W a ADDITIONAL
O O a a u� p W a w PL LL DATA/
a ¢ W O m w�r Y W REMARKS
W Surface Elevation:4,717 J o m 00 N VALUE ❑ BLOWS/FT
C7 w m o m z z ?? IL I__ 10 20 30 40
0 3-inches Asphalt Pavement, black 5 13 Surface Elevation from
0.3 "716.I
7 4/18 Google Earth
2-inches Road Base, Well Graded Gravel wit6 1 1 8% ❑
7s/°
Sand, GW; moist, brown, subrounded to
subangular, fine to coarse grained sand3 6 Lab#17-16
0.4 "716. 3 13/16 Nat.Moisture=16.4%
Fill, Sandy Lean Clay with Gravel, CL; moist3 2 72% ❑ •
3.s to slightly moist, stiff, black to dark brown,
rounded to subangular, fine to coarse grained7-17
sand, organic roots 21 3s Lab#oistu °2.1 "71q 11/18 Nat.Moisture=9.9/°Fill, Sandy Lean Clay, CL; moist, medium stiff1s 3 61%
black to dark brown, occasional rounded
gravel, fine to coarse grained sand, metal wire
5 4712.
7 Poorly Graded Gravel with Clay and Sand,
GP-GC; moist, dense, light brown to light gray
to multi-colored, rounded to subangular, fine
to coarse grained sand
5.5 4711.5.
Boring terminated at 5.5 feet
10.5 No groundwater observed
14
17.5
21
24.5
DOWL STARTED 7/31/2017 FINISHED 7/31/2017
2090 Stadium Drive DRILL CO. O'Keefe DRILL RIG MobileB-61
Bozeman, Montana 59715
D Q W L Telephone: (406) 586-8834 DRILLER M.Simmons HAMMER Auto
www.dowl.com LOGGED BY D. Barrick APPROVED BY G. Underhill