HomeMy WebLinkAbout17 - Design Report - Lakes at Valley West Ph 4 - Storm Drainage Storm Drainage Report The Lakes at Valley West, Phase 4 ,.�� �torl7gNq%�,��/✓ . o March 23, 2017 �:•MICHA GJ� Revised June 21, 2017 --o C •tug Part 1 Introduction ««nun This report provides hydrologic and hydraulic calculations for sizing of storm water conveyance and detention storage facilities for development of Phase 4 of The Lakes at Valley West subdivision. The site is located south of Phase 3. Storm drainage design follows the path set in the Phase 3 drainage report, also prepared by Morrison-Maierle: The Lakes at Valley West, Phase 3 (July 6, 2016) and Addendum to Phase 3 Drainage Report(October 12, 2016). The drainage sub-basins in this earlier report made assumptions on future phases, including Phase 4, that are no longer accurate. This Phase 4 report accounts for these changes and ensures compliance with City of Bozeman design standards. Phase 4 will be constructed as described in this report and in accordance with City of Bozeman Design Standards for drainage design. As future phases are developed, the current drainage facilities will be re-evaluated, and any required modifications will be detailed in a future report. Pre-development and post-development drainage is shown on Figures 1 and 2 respectively. Part 2 Site Description and Design Basis The site drains from south to north, discharging to Aajker Creek. "Run-on"water originating south of The Lakes at Valley West subdivision is intercepted in a constructed cutoff ditch at the south property line, and directed west to Aajker Creek. Site runoff generally discharges to the two underground treatment and detention facilities in Phase 3. The Rational Method was used to calculate peak runoff and detention requirements in accordance with City of Bozeman design standards. Runoff coefficients for Phase 4 are based on the proposed lots. Future phases are considered undeveloped in this report; additional storm drainage reports will be provided along with the development of future phases. Storm drainage infrastructure proposed for Phase 4 is identified on Figure 2. Part 3 Drainage Basins Pre-development sub-basin H1 (see Figure 1) corresponds to developed sub-basins D1.1 through D1.4 (see Figure 2). The four developed sub-basins are described below. Sub-basin D 1.1: Sub-basin D1.1 consists of the following: - D1.1A: The back yards of several residential lots within Phase 3. - D1.1 B: Offsite area to the south, plus the back yards of several residential lots in future phases along the south edge of the subdivision. - D1.1 C: The back yards of several lots along the west site boundary, within Phase 3, Phase 4 and future phases. D1.1 B runoff drains to an existing constructed cutoff ditch along the south property line, which discharges into Aajker Creek at the southwest corner of the site. Runoff from D1.1A and D1.1C will sheet flow through back yards and perimeter open space into Aajker Creek. Page 1 of 3 Sub-basin D1.2: Sub-basin D1.2 consists of D1.2A (Phase 3 runoff), D1.26 (Phase 4 runoff), and D1.2C (future phase runoff). Runoff from these areas will drain into the storm drain system and continue to detention facility D1.2, which will then discharge through the existing pair of 36%" x 22'/2" RCP arch pipes (double culvert) under Durston Road. Projections were made to account for future development of sub-basin D1.2C, in order to verify that the D1.2 detention storage volume (sized in the Phase 3 Drainage Report) will meet the anticipated future detention and storm water treatment needs of future development as well as for Phases 3 and 4. Sub-basin D 1.3: This report will utilize 4.61 cfs as the 10-year peak discharge rate out of Sub-basin D1.3, a conservative value that was calculated in the drainage report for Phases 1 and 2. This runoff flows directly into the two 36%" x 22'/2" RCP arch pipes under Durston Road. Sub-basin D1.4: Sub-basin D1.4 consists of D1.4A (runoff from Phases 2 and 3), D1.4B (runoff from Phases 1 and 2) and D1.4C (runoff from Laurel Parkway and future phases north of Phases 1 and 2). Sub-basins D1.4A and D1.413 drain to detention facility D1.4, which will then discharge through the existing pair of 36%" x 22'/2" RCP arch pipes (double culvert) under Durston Road. Sub-basin D1.4C drains to detention facility D1.4C, which discharges into the West Lake. Phase 4 runoff coefficients were calculated based on the previous (Phase 3) calculations, which were revised to reflect changes in lot and street layouts. Phase 4 calculations are attached. Part 3 Detention Basins Underground detention basin D1.2 was sized in the Phase 3 Drainage Report and will be utilized for Phase 4 runoff. This Phase 4 report will demonstrate that the Phase 3 design provides the required treatment and detention for Phase 3, the currently proposed Phase 4, and the currently anticipated future phase areas that will contribute runoff to detention basin D1.2. The following quotes, from the Phase 3 Drainage Report, apply to this Phase 4 report as well: "Two underground detention storage facilities, D1.2 and D1.4, are proposed for storm water treatment and control of the 10-year peak runoff rate. Discharge from these two detention facilities will limit the total post-development 10-year peak discharge (sub-basins D1.1 through D1.4) to the pre-development peak rate (sub-basin 1­11)." "Stored runoff will discharge through control structures. Each control structure will be a manhole with a vertical tee mounted on the discharge pipe, with a 10-year "low-flow" orifice cut into an end cap on the bottom of the tee, about a foot below the discharge pipe invert. The top of the tee, extended to an elevation matching the 10-yr maximum water surface elevation (WSEL), will serve as an overflow riser. In addition to restricting outflow to the allowable 10-year release rate, the control structures, when properly maintained, will greatly reduce the amount of floating debris and larger sediment particles discharging to the underground storage and offsite surface waters. The overflow risers and outlet pipes are sized to convey the 25-year peak runoff to the existing pair of 36%" x 22'/2" concrete arch culverts under Durston Road." Due to revised sub-basin areas and runoff coefficients, Phase 4 calculations for Detention Storage D1.2 result in a slightly lower volume requirement(5,402 cu. ft.), and lower release rate (3.51 cfs), than the Phase 3 calculations which used earlier estimates for development of Phase 4 and other future phases. Detention Storage D1.2 will be constructed with the same volume Page 2 of 3 approved in the Phase 3 drainage report, but the orifice size will be reduced to 83/8" (circular), or 75/8" x 71/4" (rectangular). The excess storage volume will be reserved for use in future phases. Part 4 Storm Water Treatment The City's design standards require Low Impact Development (LID) practices that infiltrate, evapotranspire or capture runoff, to the extent feasible, for a specified design runoff event. The proposed StormTech detention systems combine infiltration and runoff capture. The StormTech system is a widely accepted LID practice found to remove 80 percent of total suspended solids from municipal storm runoff. It meets LEED criteria for storm water treatment(SS6.2 water quality credit). The facilities proposed for this project provide over 6 inches of capture depth for infiltration and runoff volume reduction, plus treatment of additional runoff by deposition as water slowly travels through the long, linear rows of chambers. The system solves the problem of runoff "short-circuiting" from inlet to outlet that is inherent in surface detention ponds. Runoff from the first '/z" of rainfall will percolate through a gravel filter before finding its way to a perforated low-flow outlet pipe that discharges into the detention outlet structure. Additional runoff from larger storms can bypass this discharge route, but only after storage depth reaches 2 feet. Although the detention calculations assume zero infiltration, the existing alluvial (gravel/pit run) soils directly under the StormTech systems provide excellent infiltration, which further improves treatment. We believe this type of treatment not only meets, but exceeds, the City's current design standards. Part 5 Conveyance and Collection The proposed storm drain system is shown on Figure 2. Pipes were sized to convey the 25-year peak runoff from Sub-basins D1.2B and D1.2C to the Phase 3 storm drain system. Calculations are provided for representative pipes as required to assure pipe size is adequate for all pipes. These calculations assume full buildout of both of these sub-basins. Drop inlets and curb inlets are placed where needed to limit the spread of water in the street, such that an unobstructed (un-flooded) travel lane will be available during a 25-year storm, in accordance with City of Bozeman design standards. Calculations for gutter spread width and inlet intercept/bypass flows are attached. Provisions for overland flow of larger, less frequent storms up to the 100-year storm will be incorporated into the site grading. Future phasing (extension of the Phase 4 system)was taken into consideration in the placement and sizing of pipes and inlets, but final drainage design for future phases will be provided at the time of development. Phase 4 will include a temporary ditch and retention/settling basin with overflow to the West Lake, to collect and treat runoff from Sub-basin D1.2C. This retention volume is not included in the site's detention calculations, and will be removed and replaced with permanent facilities in a future phase. Calculations are attached. Design details for Phase 4 improvements will be provided on the construction drawings. N:\5352\008\Design Docs\Reports\storm\D rain age Report.docx Page 3 of 3 (this page left blank intentionally) PEAK RUNOFF AND DETENTION CALCULATIONS The Lakes at Valley West, Phase 4 Peak Runoff and Detention Calculations MODIFIED RATIONAL METHOD i=A* Tc/60)B QP=C i A QP =peak runoff,cfs Design Coefficients C =runoff coefficient Storm A B i =A(Tc/60)° (Bozeman IDF curve) 2-yr 0.36 -0.60 Te = time of concentration,minutes 5-yr 0.52 -0.64 A =Area,acres 10-yr 0.64 -0.65 25-yr 0.78 -0.64 50-yr 0.92 -0.66 1 00- r 1.01 -0.67 (Bozeman Design Standards,March 2004) Sub-Basin Name Area C Te Q2 Q5 QIo Q25 Q50 Q100 Basin 1 H1 218.30 0.20 90.60 12.27 17.44 21.38 26.16 30.60 33.46 D1.1 (A+B+C) 117.38 0.20 97.60 6.31 8.94 10.95 13.41 15.67 17.11 D1.2A 5.52 0.48 5.00 4.24 6.76 _ 8.53 10.14 12.57 14.14 D1.2B 3.48 0.50 5.00 2.78 4.44 5.60 6.66 8.25 9.29 D1.2C1 2.75 0.20 1 5.00 0.88 1.40 1.77 ! 2.10 2.61 2.94 D1.2(A+B+C)2 11.75 0.42 6.30 6.88 10.87 13.68 16.30 20.11 22.58 - - _ D1.2(future)3 11.75 0.49 I 6.30 8.02 12.68 15.97 19.02 23.47 26.36 D1 3 (West Lake outlet pipe)4_ 4 61 -- ---- -- ---- DI AA 5 72 0.50 �5 00 4 57 7.30 9 20 10 94 13.56 15.27 D1.4B 7.26 r 0.39 5.00 4.53 7.22 j 9.11 10.83 13.43 15.11 D1 4(A+B) 12.98 _�0.44 _5.00 9.10 14.52 18.32 21.78 26.99 30.38 D1.2+D1.4 24.73 I 0.43 6.30 14.80 23.39 29.44 35.08 43.29 48.61 I FOOTNOTES: 1. D1.2C represents the drainage area for a temporary storm water settling basin,for pretreatment. The settling basin is not part of the Phase 1 through 4 detention requirements. 2. D1.2(A+B+C)represents currently proposed conditions: fully developed subbasins D1.2A(previous phases)and D1.2B(Phase 4),and undeveloped subbasin D1.2C(future phases). 3. D 1.2(future)represents fully developed subbasin 1.2 including future phases at C=0.50(dense residential),for calculating detention volume. 4. Full retention of sub-basin D 1.3 was assumed to conservatively estimate the 5.14-acre lake's maximum 25-yeai water surface elevation(WSEL)at 131,184 cu. ft.,resulting in a rise of 0.59 feet above the normal operating elevation of 44.50 to which an additional 0.5 feet was added to account for partial clogging of the 2'high fish screen. The result(WSEL=45.59)was used to calculate the 25-year peak discharge. Calculations are provided in the drainage report for Phases 1 and 2. The Lakes at Valley West, Phase 4 Sub-Basin D24"/, 2 Detention (10-yr storm) MODIFIED RATIONAL METHOD Qp=CiA POST-DEVELOPMENT PRE-DEVEL. BASIN AREA POST= 11.75 AC Qp(Basin H1) = 21.38 cfs Basins D1.1+D1.3+DIA = -17.86 cfs POST-DEV C= 0.49 D1.2 release rate = 3.51 efs POST-DEV Tc= 6.3 MIN D1.2 release rate = 3.51 cfs STORM INTENSITY= 2.77 IN/HR TIME STEP POST-DEV Qp= 15.97 CFS DURATION= 5.0 min. Max.Volume, Max.Volume, Required Detention Triangle Rel.(cu.ft.)Constant Rel.(cu.ft.) Volume(cu.ft.) 6648.39 4155.95 5,402 POND VOLUME CALCULATIONS: Triangle Release Constant Release DURATION INTENSITY Qp POND VOLUME POND VOLUME (MIN) (IN/HR) (CFS) (CF) (CF) 5.99 2.86 16.51 4,632 3,620 12.29 1.79 10.34 5,664 4,156 18.59 1.37 7.90 6,189 4,155 24.89 1.13 6.54 6,472 3,898 ORIFICE CALCULATIONS 31.19 0.98 5.65 6,610 3,485 MATCHING Qp= 3.51 cfs 37.49 0.87 5.01 6,648 2,964 Max.Depth= 3.50 ft 43.79 0.79 4.53 6,614 2,364 50.09 0.72 4.15 6,522 1,702 56.39 0.67 3.84 6,386 992 62.69 0.62 3.59 6,212 240 CIRCULAR ORIFICE: 68.99 0.58 3.37 6,008 -545 DIAMETER=JIM inches 75.29 0.55 3.18 5,777 -1,359 Area= 0.38 ft' 81.59 0.52 3.02 5,522 -2,199 ORIFICE FLOW= 3.45 CFS 87.89 0.50 2.88 5,248 -3,061 94.19 0.48 2.75 4,956 -3,943 100.49 0.46 2.64 4,648 -4,842 RECTANGULAR ORIFICE: 106.79 0.44 2.54 4,326 -5,757 LENGTH= 7.625 inches 113.09 0.42 2.44 3,991 -6,687 WIDTH= 7.250 inches 119.39 0.41 2.36 3,645 -7,629 Area= 0.38 ft 2 125.69 0.40 2.28 39287 -8,584 ORIFICE FLOW= 3.46 CFS 131.99 0.38 2.21 2,920 -9,549 138.29 0.37 2.14 2,543 -10,525 144.59 0.36 2.08 2,159 -11,510 150.89 0.35 2.03 1,766 -12,504 157.19 0.34 1.97 1,366 -13,506 WEIR CALCULATIONS 163.49 0.33 1.92 960 -14,515 Coefficient= 3.33 inches 169.79 0.33 1.88 547 -15,532 Width=j_. ffift.inches 176.09 0.32 1.83 128 -16,556 WEIR FLOW= 3.41 CFS 182.39 0.31 1.79 -297 -17,586 188.69 0.30 1.75 -727 -18,622 194.99 0.30 1.71 -1,162 -19,664 DURATION INTENSITY Qp POND VOLUME POND VOLUME (MIN) (IN/HR) (CFS) (CF) (CF) 201.29 0.29 1.68 -1,602 -20,711 207.59 0.29 1.65 -2,046 -21,764 213.89 0.28 1.61 -2,495 -22,821 220.19 0.27 1.58 -2,947 -23,883 226.49 0.27 1.56 -3,404 -24,949 232.79 0.27 1.53 -3,864 -26,020 239.09 0.26 1.50 -4,328 -27,095 245.39 0.26 1.48 -4,796 -28,173 251.69 0.25 1.45 -5,266 -29,256 257.99 0.25 1.43 -5,740 -30,341 264.29 0.24 1.41 -6,216 -31,431 270.59 0.24 1.39 -6,696 -32,523 276.89 0.24 1.37 -7,178 -33,619 283.19 0.23 1.35 -7,663 -34,718 289.49 0.23 1.33 -8,151 -35,820 295.79 0.23 1.31 -8,641 -36,925 302.09 0.22 1.29 -9,133 -38,033 308.39 0.22 1.27 -9,628 -39,143 314.69 0.22 1.26 -10,125 -40,256 320,99 0.22 1.24 -10,624 -41,371 327.29 0.21 1.22 -11,126 -42,489 333.59 0.21 1.21 -11,629 -43,609 339.89 0.21 1.20 -12,134 -44,731 346.19 0.20 1.18 -12,641 -45,856 352.49 0.20 1.17 -13,150 -46,982 358.79 0.20 1.15 -13,661 -48,111 365.09 0.20 1.14 -14,174 -49,242 371.39 0.20 1.13 -14,688 -50,375 377.69 0.19 1.12 -15,204 -51,509 383.99 0.19 1.10 -15,721 -52,646 390.29 0.19 L09 -16,240 -53,784 396.59 0.19 1.08 -16,761 -54,924 402.89 0.19 1.07 -17,283 -56,066 409.19 0.18 1.06 -17,806 -57,210 415.49 0.18 1.05 -18,331 -58,355 421.79 0.18 1.04 -18,858 -59,502 428.09 0.18 1.03 -19,385 -60,650 434.39 0.18 1.02 -19,914 -61,800 440.69 0.18 1.01 -20,444 -62,952 446.99 0.17 1.00 -20,976 -64,104 453.29 0.17 0.99 -21,508 -65,259 459.59 0.17 0.98 -22,042 -66,414 465.89 0.17 0.97 -22,577 -67,571 472.19 0.17 0.97 -23,113 -68,730 478.49 0.17 0.96 -23,650 -69,889 484.79 0.16 0.95 -24,189 -71,050 491.09 0.16 0.94 -24,728 -72,212 497.39 0.16 0.93 25,268 -73,376 503.69 0.16 0.93 -25,810 -74,540 509.99 0.16 0.92 -26,352 -75,706 516.29 0.16 0.91 -26,895 -76,873 522.59 0.16 0.90 -27,440 -78,041 528.89 0.16 0.90 -27,985 -79,210 535.19 0.15 0.89 -28,531 -80,381 541.49 0.15 0.88 -29,078 -81,552 547.79 0.15 0.88 -29,626 -82,724 554.09 0.15 0.87 -30,175 -83,898 560.39 0.15 0.86 -30,725 -85,072 566.69 0.15 0.86 -31,275 -86,247 572.99 0.15 0.85 -31,827 -87,424 579.29 0.15 0.85 -32,379 -88,601 585.59 0.15 0.84 -32,932 -89,779 The Lakes at Valley West, Phase 4 Sub-Basin D�d StormTech Sizing Calculations Required Storage Volume 5,402 ft3 StormTech Modules, Model No. SC740 (30" chamber height) Depth to top of gravel 36 in. installed storage volume 74.9 ft3 per chamber(see note 1) Number of chambers required 73 72.13 before rounding excess storage volume 1.2 % Number of chambers proposed 77 excess storage volume 6.3 % equal to 342 ft3 excess storage volume Installed chamber footprint (per chamber) = 5' x 7.12' Note: add 2' min. to each row, for end caps Storage Volume Provided= 5,744 ft3 Notes: 1. Storage volume assumes 6"of stone above and below chambers,and 40%stone porosity. ® 01�1�11JOlY PROJECT: IJotEFF /a1 'tJ G 3 2/ /7 PROD.NO. ®® MAIERLE,INC, __f.CHK: DATE PAGE: OF 1 �vxl�� U T C4�p�(�Cifi.= lS �r.lP- �_v.�. :��� fl.^• EafF�.,I.•F 'S1r1 � — ��'1�f.�� � f f (!/ F�.g'/fi 1VI ��� Y�1fli 3 1�V �1/q<�li j'"Q/✓1P6-'� /oD 7 jj dGve-lopr, (, c = p. 20 /pp ./r � �) C = D.z;�' y� l�. �o uy o. � ( Iy/ = o, �/3 �-v+1��7vc ��r�v�V►r+� '�� �F��Ifr'�y 3������ �n �-2fl � I-z�� !� cr, GUTTER FLOW CALCULATIONS The Lakes at Valley West, Phase 4 Gutter Flow, Direct (Surface) Runoff Calculations MODIFIED RATIONAL METHOD QP=C i A QP =25-yr peak runoff,cfs� C =runoff coefficient i =0.78(Tc/60)-"14 (Bozeman IDF curve) T, = time of concentration,minutes A =Area, acres Sub-Basin Description Area' T, C Q, Herstal Way North end 1.12 5.00 0.50 2.14 Vaughn Drive Future curb inlet,west of Westgate, south side 1.02 5.00 0.50 1.95 Future curb inlet,west of Westgate,north side 0.59 5.00 0.50 1.13 Westgate Avenue North of Herstal,west side 1.09 5.00 0.50 2.09 North of Herstal,east side 0.60 5.00 0.50 1.15 North end,west side park inlet 0.93 5.00 0.50 1.78 North end,west side 0.53 5.00 0.50 1.01 North end, east side 0.63 5.00 0.50 1.21 Roundabout,inlet at south quadrant 1.56 5.00 0.50 2.98 Westmoreland Drive West of roundabout, south side,from west 1.45 5.00 0.50 2.77 Low point east of Westgate, south side 1.95 5.00 0.48 3.58 FOOTNOTES: 1 Areas and flow rates are for direct runoff only and do not include inlet bypass. Inlet bypass flow is accounted for on the following page. 2 Herstal Way is an alley;typical section is an inverted crown with 2%slope toward the center. The Lakes at Valley West,Phase 4 Gutter Spread Width Calculations 25- r.Peak Runoff(cfs) Gutter Sub-Basin Description Directs Upstream2 Total Inlet Type Bypass Spread(ft.) Herstal Way, North end 2.14 0.00 2.14 n/a n/a 13.58 Vaughn Drive Future curb inlet,west of Westgate,south side 1.95 0.00 1.95 sag 0.00 7.93 Future curb inlet,west of Westgate,north side 1.13 0.00 1.13 sag 0.00 6.38 Westgate Avenue North of Herstal,west side 2.09 0.00 2.09 on grade 0.69 8.01 North of Herstal,east side 1.15 0.00 1.15 on grade 0.25 6.32 North end,west side park inlet 1.78 0.00 1.78 drop inlet 0.00 n/a North end,west side 1.01 0.69 1.70 on grade 0.50 7.38 North end,east side 1.21 0.25 1.46 on grade 0.38 6.96 Roundabout,inlet at south quadrant 2.98 0.50 3.48 sag 0.00 8.81 Westmoreland Drive West of roundabout,south side,from west 2.77 0.00 2.77 n/a 0.00 9.41 Low point east of Westgate,south side 3.58 0.38 3.96 sag 0.00 9.49 FOOTNOTES: 1 Direct runoff is from"Gutter Flow"calculations on the previous page,and does not include runoff from upstream inlets. 2 Upstream runoff is the bypass flow from contributing upstream inlets. 3 For Ostend Lane and Herstal Way(minor alleys with inverted crown),minor submergence is acceptable. The maximum submergence at the wheels of a car straddling the inverted crown centerline would be about 1 inch,which is considered acceptble for the short duration of peak runoff involved. 4 Maximum(25-yr)flow to this drop inlet also includes 0.21 cfs form the other(east)side,which does not affect spread width. Herstal, N. end (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.013 Channel Slope 1.50 % Left Side Slope 2.00 % Right Side Slope 2.00 % Discharge 2.14 ft'/s Results Normal Depth 1.63 in Flow Area 0.92 ft2 Wetted Perimeter 13.58 ft Hydraulic Radius 0.81 in Top Width 13.58 ft Critical Depth 0.16 ft Critical Slope 0.00569 ft/ft Velocity 2.32 ft/s Velocity Head 0.08 ft Specific Energy 0.22 ft Froude Number 1.57 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.63 in Critical Depth 0.16 ft Channel Slope 1.50 % Critical Slope 0.00569 ft/ft Bentley Systems,Inc. Haestad Methods SdbAkkW fekt*Master V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 11:54:07 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 Vaugn, gutter at S. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.60 % Discharge 1.95 ft3/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options Lurrent Kougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 3.27 in Elevation Range 0.00 to 0.48 ft Flow Area 0.93 ftz Wetted Perimeter 8.12 ft Hydraulic Radius 1.38 in Top Width 7.93 ft Normal Depth 3.27 in Critical Depth 0.28 ft Critical Slope 0.00514 ft/ft Bentley Systems,Inc. Haestad Methods SdbmhdatEEkhWaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 2:42:51 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Vaugn, gutter at S. inlet (25-yr) Results Velocity 2.09 ft/s Velocity Head 0.07 ft Specific Energy 0.34 ft Froude Number 1.07 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.27 in Critical Depth 0.28 ft Channel Slope 0.60 % Critical Slope 0.00514 ft/ft Bentley Systems,Inc. Haestad Methods ScIfth ia)PfeMeiVlaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 2:42:51 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Vaughn, S. inlet Project Description Solve For Spread Input Data Discharge 1.95 ft3/s Gutter Width 1.50 ft Gutter Cross Slope 6.25 % Road Cross Slope 3.00 Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30'Tilt Bar Clogging 20.00 % Curb Opening Length 3.00 ft Opening Height 5.00 in Curb Throat Type Vertical Throat Incline Angle 0.00 degrees Options Calculation Option Use Both Results Spread 6.26 ft Depth 2.84 in Gutter Depression 0.05 ft Total Depression 0.13 ft Open Grate Area 1.22 ft2 Active Grate Weir Length 5.40 ft Bentley Systems,Inc. Haestad Methods SdiOel")CEekbmMaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 1:45:16 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 Vaugn, gutter at N. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.60 % Discharge 1.13 ft'/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options t;urrent Kougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 2.74 in Elevation Range 0.00 to 0.48 ft Flow Area 0.62 ft2 Wetted Perimeter 6.54 ft Hydraulic Radius 1.13 in Top Width 6.38 ft Normal Depth 2.74 in Critical Depth 0.23 ft Critical Slope 0.00552 ft/ft Bentley Systems,Inc. Haestad Methods ScIbeiiblooktaMaster V8i(SELECTseries 1) [08.11.01.03] 6/21/2017 4:25:26 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Vaugn, gutter at N. inlet (25-yr) Results Velocity 1.83 ft/s Velocity Head 0.05 ft Specific Energy 0.28 ft Froude Number 1.04 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.74 in Critical Depth 0.23 ft Channel Slope 0.60 % Critical Slope 0.00552 ft/ft Bentley Systems,Inc. Haestad Methods SdDmkide)FfehftMaster V8i(SELECTseries 1) [08.11.01.03] 6/21/2017 4:25:26 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Vaughn, N. inlet Project Description Solve For Spread Input Data Discharge 1.13 W/s Gutter Width 1.50 ft Gutter Cross Slope 6.25 % Road Cross Slope 3.00 % Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30'Tilt Bar Clogging 20.00 % Curb Opening Length 3.00 ft Opening Height 5.00 in Curb Throat Type Vertical Throat Incline Angle 0.00 degrees Options Calculation Option Use Both Results Spread 4.48 ft Depth 2.20 in Gutter Depression 0.05 ft Total Depression 0.13 ft Open Grate Area 1.22 ft2 Active Grate Weir Length 5.40 ft Bentley Systems,Inc. Haestad Methods SdhaV6ajCEh1wNlaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 1:46:21 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 Westgate, gutter N. of Herstal at W. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.65 Discharge 2.09 ft'/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options Lurrent Kougnness vveigntea Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 3.30 in Elevation Range 0.00 to 0.48 ft Flow Area 0.95 ftz Wetted Perimeter 8.20 ft Hydraulic Radius 1.39 in Top Width 8.01 ft Normal Depth 3.30 in Critical Depth 0.29 ft Critical Slope 0.00509 ft/ft Bentley Systems,Inc. Haestad Methods Sdb@kkY 1M4tt&Master V8i(SELECTseries 1) [08.11.01.03] 6/22/2017 8:03:14 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Westgate, gutter N. of Herstal at W. inlet (25-yr) Results Velocity 2.20 ft/s Velocity Head 0.07 ft Specific Energy 0.35 ft Froude Number 1.12 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.30 in Critical Depth 0.29 ft Channel Slope 0.65 % Critical Slope 0.00509 ft/ft Bentley Systems,Inc. Haestad Methods Sc1NWbtWjCEt1eiVlaster V8i(SELECTseries 1) [08.11.01.03] 6/2212017 8:03:14 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Westgate, N. of Herstal, W. inlet (25-yr) Project Description Solve For Efficiency Input Data Discharge 2.09 ft'/s Slope 0.65000 % Gutter Width 1.50 ft Gutter Cross Slope 6.30 Road Cross Slope 3.00 Roughness Coefficient 0.013 Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30°Tilt Bar Clogging 20.00 Curb Opening Length 3.00 ft Options Calculation Option Use Both Grate Flow Option Exclude None Results Efficiency 67.06 % Intercepted Flow 1.40 ft'/s Bypass Flow 0.69 W/s Spread 7.13 ft Depth 3.16 in Flow Area 0.80 ft2 Gutter Depression 0.05 ft Total Depression 0.13 ft Velocity 2.61 ft/s Splash Over Velocity 5.18 ft/s Frontal Flow Factor 1.00 Side Flow Factor 0.21 Grate Flow Ratio 0.52 Equivalent Cross Slope 0.07601 ft/ft Active Grate Length 2.40 ft Length Factor 0.05 Total Interception Length 11.47 ft Bentley Systems,Inc. Haestad Methods Sc1bghtlooktaf faster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 2:27:50 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 Westgate, gutter N. of Herstal at E. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.65 % Discharge 1.15 ft'/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options t;urrent I-cougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 2.72 in Elevation Range 0.00 to 0.48 ft Flow Area 0.61 ft2 Wetted Perimeter 6.48 ft Hydraulic Radius 1.12 in Top Width 6.32 ft Normal Depth 2.72 in Critical Depth 0.23 ft Critical Slope 0.00551 ft/ft Bentley Systems,Inc. Haestad Methods SdbzkbW)CEkt*Master V8i(SELECTseries 1) [08.11.01.03] 6/22/2017 7:46:58 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Westgate, gutter N. of Herstal at E. inlet (25-yr) Results Velocity 1.90 ft/s Velocity Head 0.06 ft Specific Energy 0.28 ft Froude Number 1.08 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.72 in Critical Depth 0.23 ft Channel Slope 0.65 % Critical Slope 0.00551 ft/ft Bentley Systems,Inc. Haestad Methods SdhgkkI9jCE Waster V8i(SELECTseries 1) 108.11.01.03] 6/22/2017 7:46:58 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Westgate, N. of Herstal, E. inlet (25-yr) Project Description Solve For Efficiency Input Data Discharge 1.15 ft3/s Slope 0.65000 % Gutter Width 1.50 ft Gutter Cross Slope 6.30 % Road Cross Slope 3.00 % Roughness Coefficient 0.013 Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30'Tilt Bar Clogging 20.00 % Curb Opening Length 3.00 ft Options Calculation Option Use Both Grate Flow Option Exclude None Results Efficiency 78.06 % Intercepted Flow 0.90 ft3/s Bypass Flow 0.25 ft'/s Spread 5.57 ft Depth 2.60 in Flow Area 0.50 ftz Gutter Depression 0.05 ft Total Depression 0.13 ft Velocity 2.29 . ft/s Splash Over Velocity 5.18 ft/s Frontal Flow Factor 1.00 Side Flow Factor 0.25 Grate Flow Ratio 0.63 Equivalent Cross Slope 0.08598 ft/ft Active Grate Length 2.40 ft Length Factor 0.07 Total Interception Length 8.29 ft Bentley Systems,Inc. Haestad Methods Sdba ibloo taiMaster V8i(SELECTseries 1) [08.11.01.03] 6120/2017 2:26:17 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 Westgate, gutter at N. end, W. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.65 % Discharge 1.70 ft'/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options L;urrent Kougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 3.09 in Elevation Range 0.00 to 0.48 ft Flow Area 0.81 ft2 Wetted Perimeter 7.56 ft Hydraulic Radius 1.29 in Top Width 7.38 ft Normal Depth 3.09 in Critical Depth 0.27 ft Critical Slope 0.00523 ft/ft Bentley Systems,Inc. Haestad Methods SdiAeli6ia0kt*Master V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 2:22:44 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Westgate, gutter at N. end, W. inlet (25-yr) Results Velocity 2.09 ft/s Velocity Head 0.07 ft Specific Energy 0.32 ft Froude Number 1.11 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.09 in Critical Depth 0.27 ft Channel Slope 0.65 % Critical Slope 0.00523 ft/ft Bentley Systems,Inc. Haestad Methods SdDakidej:felawMaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 2:22:44 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755.1666 Page 2 of 2 Westgate, N. end, W. inlet (25-yr) ,Project Description Solve For Efficiency Input Data Discharge 1.70 ft'/s Slope 0.65000 Gutter Width 1.50 ft Gutter Cross Slope 6.30 % Road Cross Slope 3.00 Roughness Coefficient 0.013 Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30°Tilt Bar Clogging 20.00 Curb Opening Length 3.00 ft Options Calculation Option Use Both Grate Flow Option Exclude None Results Efficiency 70.87 Intercepted Flow 1.20 ft'/s Bypass Flow 0.50 ft'/s Spread 6.56 ft Depth 2.95 in Flow Area 0.68 ft2 Gutter Depression 0.05 ft Total Depression 0.13 ft Velocity 2.49 fUs Splash Over Velocity 5.18 ft/s Frontal Flow Factor 1.00 Side Flow Factor 0.22 Grate Flow Ratio 0.56 Equivalent Cross Slope 0.07931 ft/ft Active Grate Length 2.40 ft Length Factor 0.06 Total Interception Length 10.25 ft Bentley Systems,Inc. Haestad Methods Sc&ebtie)Xeic*Master V6i(SELECTseries 1) 108.11.01.03] 6/20/2017 2:55:04 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 Westgate, gutter at N. end, at E. inlet (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.65 % Discharge 1.46 ft'/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options t;urrent rrougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 2.94 in Elevation Range 0.00 to 0.48 ft Flow Area 0.73 ft2 Wetted Perimeter 7.14 ft Hydraulic Radius 1.22 in Top Width 6.96 ft Normal Depth 2.94 in Critical Depth 0.25 ft Critical Slope 0.00534 f ft Bentley Systems,Inc. Haestad Methods Sd alklo fekMiNaster V8i(SELECTseries 1) [08.11.01.031 6/21/2017 4:42:07 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203.755-1666 Page 1 of 2 Westgate, gutter at N. end, at E. inlet (25-yr) Results Velocity 2.01 ft/s Velocity Head 0.06 ft Specific Energy 0.31 ft Froude Number 1.09 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.94 in Critical Depth 0.25 ft Channel Slope 0.65 % Critical Slope 0.00534 ft/ft Bentley Systems,Inc. Haestad Methods Sdhekbdef*kNWaster V8i(SELECTseries 1) [08.11.01.03] 6/21/2017 4:42:07 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Westgate, N. end, E. inlet (25-yr) Project Description Solve For Efficiency Input Data Discharge 1.46 ft'/s Slope 0.65000 % Gutter Width 1.50 ft Gutter Cross Slope 6.30 % Road Cross Slope 3.00 % Roughness Coefficient 0.013 Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30'Tilt Bar Clogging 20.00 Curb Opening Length 3.00 ft Options Calculation Option Use Both Grate Flow Option Exclude None Results Efficiency 73.68 % Intercepted Flow 1.08 ft-1/s Bypass Flow 0.38 W/s Spread 6.16 ft Depth 2.81 in Flow Area 0.61 ftz Gutter Depression 0.05 ft Total Depression 0.13 ft Velocity 2.41 ft/s Splash Over Velocity 5.18 ft/s Frontal Flow Factor 1.00 Side Flow Factor 0.24 Grate Flow Ratio 0.59 Equivalent Cross Slope 0.08185 ft/ft Active Grate Length 2.40 ft Length Factor 0.06 Total Interception Length 9.44 ft Bentley Systems,Inc. Haestad Methods Sdbek"oktaMaster V8i(SELECTseries 1) 108.11.01.03] 6/22/2017 7:31:00 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203.755.1666 Page 1 of 2 Westgate/Westmoreland roundabout, S. inlet Project Description Solve For Spread Input Data Discharge 3.48 ft'/s Gutter Width 1.50 ft Gutter Cross Slope 6.25 % Road Cross Slope 3.00 % Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30°Tilt Bar Clogging 20.00 % Curb Opening Length 3.00 ft Opening Height 5.00 in Curb Throat Type Vertical Throat Incline Angle 0.00 degrees Options Calculation Option Use Both Results Spread 8.81 ft Depth 3.76 in Gutter Depression 0.05 ft Total Depression 0.13 ft Open Grate Area 1.22 ft2 Active Grate Weir Length 5.40 ft Bentley Systems,Inc. Haestad Methods Scibefidepe"W&Vlaster V81(SELECTseries 1) [08.11.01.03] 6/21/2017 4:49:17 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 1 South gutter at Ph 3 roundabout, from west (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Channel Slope 0.50 % Discharge 2.77 ft3/s Section Definitions Station(ft) Elevation(ft) 0+00.33 0.45 0+00.50 0.00 0+02.00 0.09 0+15.50 0.48 Roughness Segment Definitions Start Station Ending Station Roughness Coefficient (0+00.33,0.45) (0+15.50,0.48) 0.013 Options current rtougnness vveignteo Pavlovskii's Method Method Open Channel Weighting Method Pavlovskii's Method Closed Channel Weighting Method Pavlovskii's Method Results Normal Depth 3.78 in Elevation Range 0.00 to 0.48 ft Flow Area 1.30 ft2 Wetted Perimeter 9.64 ft Hydraulic Radius 1.62 in Top Width 9.41 ft Normal Depth 3.78 in Critical Depth 0.32 ft Critical Slope 0.00491 ft/ft Bentley Systems,Inc. Haestad Methods SdbAkidaf:EMwM aster V8i(SELECTseries 1) [08.11.01.03] 6/21/2017 4:46:28 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 South gutter at Ph 3 roundabout, from west (25-yr) Results Velocity 2.13 ft/s Velocity Head 0.07 ft Specific Energy 0.39 ft Froude Number 1.01 Flow Type Supercritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.78 in Critical Depth 0.32 ft Channel Slope 0.50 % Critical Slope 0.00491 ft/ft Bentley Systems,Inc. Haestad Methods Sd3et"ICEW&NIaster V8i(SELECTseries 1) [08.11.01.03] 6/21/2017 4:46:28 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2 Westmorland, low point E. of Westgate, S. side (25-yr) Project Description Solve For Spread Input Data Discharge 3.96 ft3/s Gutter Width 1.50 ft Gutter Cross Slope 6.25 % Road Cross Slope 3.00 % Local Depression 1.00 in Local Depression Width 1.50 ft Grate Width 1.50 ft Grate Length 3.00 ft Grate Type 30'Tilt Bar Clogging 20.00 % Curb Opening Length 3.00 ft Opening Height 5.00 in Curb Throat Type Vertical Throat Incline Angle 0.00 degrees Options Calculation Option Use Both Results Spread 9.49 ft Depth 4.00 in Gutter Depression 0.05 ft Total Depression 0.13 ft Open Grate Area 1.22 ftz Active Grate Weir Length 5.40 ft Bentley Systems,Inc. Haestad Methods SdDmkWAe10EkteMaster V8i(SELECTseries 1) [08.11.01.03] 6/22/2017 7:36:51 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203.755-1666 Page 1 of 1 PIPE FLOW CALCULATIONS The Lakes at Valley West,Phase 4 Pipe Flow Calculations MODIFIED RATIONAL METHOD QP=C i A Qp =25-yr peak runoff,cfs C =runoff coefficient i =0.78(Tc/60y"' (Bozeman IDF curve) T, = time of concentration,minutes A =Area,acres Sub-Basin Description Area I Tc d Qirect C Z Qtotal `lint Qbr lass' a Q s Pipe Dia. Notes �i�c i I Vaughn Drive Future curb inlet,west of Westgate,south side 1.02 5.00 0.50 1.95 1.95 1.95, 0.00 1.95 12" Future curb inlet,west of Westgate,north side 0.59 5.00 0.50 1.13 1.13 1.13 0.00 3.08 12" Westizate Avenue North of Herstal,west side 1.09 5.00 0.50 2.09 2.09 1.40 0.69 1.40 12" North of Herstal,east side 0.60 5.00 0.50 1.15 1.15 0.90 0.25 I 5.37 18" see note North end,west side park inlet 0.93 5.00 0.50 1.78 1.78 1.78 0.00 1.78 12" North end,west side 0.53 5.00 0.50 1.01 1.70 1.45 0.25 3.23 15" North end,east side 0.63 5.00 0.50 1.21 1.46 1.08 0,38 6A5 24" see notes Roundabout,inlet at south quadrant 1.56 5.00 0,50 2.98 3.23 3.23 0.00 3.23 15" see note9 Roundabout,NM at east quadrant 0.00 i 9.68 9.68 24" see note9 I � Westmoreland Drive i Low point east of Westgate,south side 1.95 5.00 0.48 3.58 3.96 3.96 0.00 3.96 15" see note FOOTNOTES: 1 Contributing drainage area 2 Qdi,,,l is direct surface runoff to the inlet,and does not include bypass flows from upstream inlets. 3 Qt tat is total peak surface runoff to the inlet(direct runoff plus bypass flows from upstream inlets). 4 %,i is surface runoff intercepted by the inlet. 5 Qpji is total flow to outlet pipe(total pipe flow from upstream inlets plus surface runoff intercepted at the inlet). 6 Calculations are attached where"Pipe Dia."column uses bold text. Other pipe sizes are evident based on flow rates. 7 Flow rate is close to 15"pipe capacity,so 18"pipe is recommended due to potentially higher flows in future phases. 8 Although 18"pipe has enough capacity,24"pipe was installed to the phase line during Phase 3 construction due to potentially higher flows in future phases. The existing 24"pipe will be extended to the Phase 4 inlet. 9 This pipe was installed during Phase 3,based on Phase 3 drainage calculations. The above Phase 4 calculations show that installed pipes are adequately sized. 12" pipe (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.013 Channel Slope 0.60 % Diameter 12.00 in Discharge 1.95 ft3/s Results Normal Depth 7.45 in Flow Area 0.51 ft2 Wetted Perimeter 1.81 ft Hydraulic Radius 3.39 in Top Width 0.97 ft Critical Depth 0.60 ft Percent Full 62A % Critical Slope 0.00679 ft/ft Velocity 3.81 ft/s Velocity Head 0.23 ft Specific Energy 0.85 ft Froude Number 0.92 Maximum Discharge 2.97 ft3/s Discharge Full 2.76 ft3/s Slope Full 0.00300 ft/ft Flow Type SubCritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 Normal Depth Over Rise 62.05 % Downstream Velocity Infinity ft/s Bentley Systems,Inc. Haestad Methods Sdbzkide¢EkWiVlaster V8i(SELECTseries 1) [08.11.01.03] 6/20/2017 3:44:59 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 15" pipe (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.013 Channel Slope 0.60 % Diameter 15.00 in Discharge 3.96 ft3/s Results Normal Depth 10.07 in Flow Area 0.88 ft2 Wetted Perimeter 2.40 ft Hydraulic Radius 4.38 in Top Width 1.17 ft Critical Depth 0.81 ft Percent Full 67.1 % Critical Slope 0.00674 ft/ft Velocity 4.52 ft/s Velocity Head 0.32 ft Specific Energy 1.16 ft Froude Number 0.92 Maximum Discharge 5.38 ft'/s Discharge Full 5.00 ft'/s Slope Full 0.00376 ft/ft Flow Type SubCritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 % Normal Depth Over Rise 67.12 Downstream Velocity Infinity ft/s Bentley Systems,Inc. Haestad Methods SdbAi6Y 0kWMaster V8i(SELECTseries 1) [08.11.01.03] 6/22/2017 7:35:01 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203.755-1666 Page 1 of 2 18" pipe (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.013 Channel Slope 0.60 % Diameter 18.00 in Discharge 5.37 ft3/s Results Normal Depth 10.68 in Flow Area 1.09 ft2 Wetted Perimeter 2.64 ft Hydraulic Radius 4.97 in Top Width 1.47 ft Critical Depth 0.89 ft Percent Full 59.3 % Critical Slope 0.00593 ft/ft Velocity 4.92 ft/s Velocity Head 0.38 ft Specific Energy 1.27 ft Froude Number 1.01 Maximum Discharge 8.75 ft3/s Discharge Full 8.14 ft3/s Slope Full 0.00261 ft/ft Flow Type SuperCritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 Normal Depth Over Rise 59.32 Downstream Velocity Infinity ft/s Bentley Systems,Inc. Haestad Methods SoRd dtegEdderMaster V8i(SELECTseries 1) [08.11.01.03] 6/22/2017 10:25:29 AM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 24" pipe (25-yr) Project Description Friction Method Manning Formula Solve For Normal Depth .Input Data Roughness Coefficient 0.013 Channel Slope 0.60 % Diameter 24.00 in Discharge 9.82 ft'/s Results Normal Depth 12.85 in Flow Area 1.71 ft2 Wetted Perimeter 3.28 ft Hydraulic Radius 6.26 in Top Width 2.00 ft Critical Depth 1.12 ft Percent Full 53.5 % Critical Slope 0.00517 ft/ft Velocity 5.74 ft/s Velocity Head 0.51 ft Specific Energy 1.58 ft Froude Number 1.09 Maximum Discharge 18.85 ft/s Discharge Discharge Full 17.52 ft'/s Slope Full 0.00188 ft/ft Flow Type SuperCritical GVF Input Data Downstream Depth 0.00 in Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 in Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 % Normal Depth Over Rise 53.53 % Downstream Velocity Infinity ft/s Bentley Systems,Inc. Haestad Methods Scl3wki i&)C5kteMaster V81(SELECTseries 1) [08.11.01.03] 6/20/2017 4:02:26 PM 27 Siemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2 __- 4 _39 T. 1 i a 0 1000I I J • . •MJI.J / ' ✓THE LAKES AT VALLEY WEST DURSTON ROAD �- V � • H2 0 PHASE 4 7 6 0 Q Q o U 1 Q Z 0 rH 1 I 0 4786AT � ,65.3 � -o x ili1_�iII�IlIF1� ��� I I ►"'- '7 BABCOCK STR E mac, Li it 91r I i !� C1931HUFFINE LANE I r 1 2880TechnologyBlvd West DRAWN BY: CJF THE LAKES AT VALLEY WEST PROJECT NO. Morrison Bozeman,MT 59718 DSGN.BY: MGH PHASE 4 5352.008 �■ M a i e rl a Phone:406.587.0721 BOZEMAN MONTANA Fax:406.922.6702 APPR.BY: JRN FIGURE NUMBER engineers•surveyors•planners•scientists PRE-DEVELOPMENT DRAINAGE FIG. 1 COPYRIGHT 0 MORRIRON-MAIERLE,INC.,MlT DATE: 01/2017 1:\5352\0081ACAD\Exhibits\PH 4 Pre-Development.dwg Plotted by cody fadey on Jan123/2017